Search
Close this search box.

WE HANDLE INQUIRIES THROUGH EMAIL MORE EFFICIENTLY

WE HANDLE INQUIRIES THROUGH EMAIL MORE EFFICIENTLY

Euchner EUCHNER CES-A-ABA-01B

EUCHNER HBA-113815

EUCHNER CES-A-ABA-01B

Euchner

EUCHNER HBA-113815

We are EUCHNER CES-A-ABA-01B product supplier in India

ORDER NO. 083513

Order number083513
Item designationCES-A-ABA-01B
Gross weight0,247kg
European Article Number (EAN)4047048000810
Customs tariff number85364110

Evaluation unit CES-A-ABA…/CES-A-UBA… (for 1 read head)

  • 1 read head can be connected
  • 2 safety contacts (relay contacts)
  • 1 internal normally open contact per safety contact
  • Unicode evaluation unit
  • Category 3 / PL e according to EN ISO 13849-1

Unicode evaluation unit

Each actuator is highly coded (unicode). The evaluation unit detects only actuators that have been taught-in. Max. 8 actuators can be taught-in.

Only the last actuator taught-in is detected.

Category according to EN ISO 13849-1

Due to two redundant relay outputs (safety outputs) with internally monitored contacts, suitable for:

  • Category 3 / PL e according to EN ISO 13849-1

To achieve the stated category, both safety contacts must always be evaluated.

Actuating range

The standard version of the evaluation unit (CES-A-…-01B) has a large actuating range that, e.g., permits larger tolerances in the alignment of read head and actuator. Wherever a smaller actuating range is required, the version with reduced actuating range (CES-A-…-01) can be used.

TSTInput for self-test
OUTMonitoring output (semiconductor)
ERRDiagnostic output
GNDConnected internally to 0V (not for high currents)

Work area

Repeat accuracy R
according to EN 60947-5-2max. 10 %

Controls and indicators

LED indicator
Safety output status
Status LED
Diagnostics LED

Electrical connection ratings

Connection cross-section
(screw terminals)0.25 … 2.5 mm²
Current consumption
(with relay energized)150 mA 
Fusing
external (operating voltage UB)0.25 … 8 A
Operating voltage DC
UB21 … 24 … 27 V DC regulated, residual ripple < 5%
EMC protection requirementsaccording to EN 60947-5-3
Degree of contamination (external, according to EN 60947-1)2
Input: test input TST
Input voltage
HIGH15 … UB V DC
LOW0 … 2 V DC
Monitoring outputs: diagnostics ERR, door monitoring output OUT
Output typeSemiconductor output, p-switching, not short circuit-proof
Output currentmax. 20 mA
Output voltage0.8 x UB … UB V DC
Safety contacts 13/14, 23/24
Output typeRelay contacts, floating
Fusing
external (safety circuit) according to EN 60269-16 AgG or 6 A circuit breaker (characteristic B or C)
rated conditional short-circuit current100 A
Rated insulation voltage Ui63 V
Rated impulse withstand voltage Uimp1.5 kV
Discrepancy time
(between the operating points of both relays)max. 120 ms
Switching current
at switching voltage AC/DC 21 … 60 V1 … 300 mA
at switching voltage AC/DC 10 … 30 V10 … 6000 mA
Utilization category
DC-1230 V 6 A
DC-1260 V 0.3 A
AC-1260 V 0.3 A
DC-1430 V 2 A
DC-1324 V 3 A
AC-1230 V 6 A
Switching load
according to c UL usClass 2 max. 30 V AC / Class 2 max. 60 V DC; 120 V AC 3 A / 240 V AC 1.5 A

Mechanical values and environment

Number of read heads1 read head can be connected
Connectionplug-in screw terminals, coded
Degree of protectionIP20
Ready delaymax. 3 s 
Material
HousingPlastic PA6.6
Switching frequencymax. 1 Hz 
Reaction time
after change in the actuation statusmax. 180 ms 
Atmospheric humidity
not condensingmax. 80 % rH
Mounting distance
laterally to the neighboring devicemin. 10 mm 
Mounting typeMounting rail 35 mm according to DIN EN 60715 TH35
Ambient temperature
at UB = 24V DC-20 … +55 °C
Dwell timemin. 0.5 s 
Safety contacts 13/14, 23/24
Number of safety contacts2 Relay with internally monitored contacts 
Mechanical life
Operating cycles (relay)10 x 10⁶

Reliability values acc. to EN ISO 13849-1

Diagnostic Coverage (DC)90 %
Number of switching cycles
≤ 0.1 A at 24 V DCmax. 760000 1/y
≤ 1 A at 24 V DCmax. 153000 1/y
≤ 3 A at 24 V DCmax. 34600 1/y
Mission time20 y 
Monitoring of the guard position
Category
Performance LevelPL e 
PFHD4.3 x 10-8 

Miscellaneous

The following applies to the approval according to ULOperation only with UL Class 2 power supply or equivalent measure.

In combination with read head CES-A-LQA-SC and actuator CES-A-BBA-071840, CES-A-BCA

Assured operating distances sao
for vertical approach direction (center offset m=0)min. 10 mm 
for side approach direction (distance in x direction 8 mm)min. +/- 18 mm 
Assured release distance sarmax. 47 mm
Operating distance
for side approach direction (distance in x direction 8 mm)+/- 22 mm 
for vertical approach direction (center offset m=0)15 mm 
Switching hysteresis
for vertical approach direction2 … 3 mm 
for side approach direction (distance in x direction 8 mm)1 … 1.8 mm 

In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V

Mounting distance
neighboring read headsmin. 50 mm 

In combination with read head CES-A-LQA-SC

Mounting distance
neighboring read headsmin. 80 mm 

In combination with read head CES-A-LMN-SC

Mounting distance
neighboring read headsmin. 20 mm 

In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V and actuator CES-A-BDA-20

Actuator distance s
Minimum distance for side approach directionmin. 4 mm 
Assured operating distances sao
with center offset m=0min. 11 mm 
Assured release distance sarmax. 33 mm
Operating distance
with center offset m=016 mm 
Switching hysteresis0.5 … 2 mm 

In combination with read head CES-A-LQA-SC and actuator CES-A-BQA

Assured operating distances sao
for vertical approach direction (center offset m=0)min. 16 mm 
for side approach direction (distance in x direction 10 mm)min. +/- 24 mm 
Assured release distance sarmax. 60 mm
Operating distance
for side approach direction (distance in x direction 10 mm)+/- 28 mm 
for vertical approach direction (center offset m=0)23 mm 
Switching hysteresis
for vertical approach direction2 … 3 mm 
for side approach direction (distance in x direction 10 mm)1 … 1.3 mm 

In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V and actuator CES-A-BBA-071840, CES-A-BCA

Actuator distance s
Minimum distance for side approach directionmin. 3 mm
Assured operating distances sao
with center offset m=0min. 10 mm 
Assured release distance sarmax. 32 mm
Operating distance
with center offset m=015 mm 
Switching hysteresis0.5 … 2 mm 

In combination with read head CES-A-LMN-SC and actuator CES-A-BMB

Actuator distance s
Minimum distancemin. 1.2 mm
Assured operating distances sao
with center offset m=0min. 3.5 mm 
Assured release distance sarmax. 10 mm
Operating distance
with center offset m=05 mm 
Switching hysteresis0.1 … 0.3 mm 
Still not sure what you want?

We are here to help you, send us your details we will assist you to choose right product.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Know the part number Search here
EUCHNER HBA-113815

EUCHNER CES-A-ABA-01B

Fill up the form and we will get back to you in few hours with right details. fill the form to help you better way.