Search
Close this search box.

WE HANDLE INQUIRIES THROUGH EMAIL MORE EFFICIENTLY

WE HANDLE INQUIRIES THROUGH EMAIL MORE EFFICIENTLY

Euchner Euchner CES-I-AP-U-C04-U05

EUCHNER HBA-113815

Euchner CES-I-AP-U-C04-U05

Euchner

We are Euchner CES-I-AP-U-C04-U05 product supplier in India

116503

Non-contact safety switches CES-I-AP-.- C04-…, flying lead

  • Safety switch with integrated evaluation electronics
  • No series connection
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Category 4 / PL e according to EN ISO 13849-1
  • Three active faces
  • Connecting cable PUR, 5 m, flying lead
  • Unicode
  • Monitoring output OD

Installation position

Permissible installation position

Unicode evaluation

Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can be taught-in. Only the last actuator taught-in is detected.

Category according to EN 13849-1

Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:

  • Category 4/PL e according to EN 13849-1

Important: To achieve the stated category according to EN ISO 13849-1, both safety outputs (FO1A and FO1B) must be evaluated.

LED indicator

STATEStatus LED
DIADiagnostic LED

Terminal assignment

DesignationFunctionConductor coloring of connecting cable
UBPower supply, DC 24 VBN
FO1ASafety output, channel 1WH
0VGround, DC 0 VBU
FO1BSafety output, channel 2BK
ODMonitoring outputGY

Technical Data

Work area

Repeat accuracy R
according to EN 60947-5-2<= 10

Electrical connection ratings

Current consumption
no load on outputsmax. 35 mA
Degree of contamination (external, according to EN 60947-1)3
EMC protection requirementsaccording to EN IEC 60947-5-3
Fusing
external (operating voltage)0.25 … 8 A
Operating voltage DC
UB24 V DC -15% … +15% regulated, residual ripple 5%, PELV 
Rated impulse withstand voltage Uimp1.5 kV
Rated insulation voltage Ui300 V
Risk time according to EN 60947-5-3max. 260 ms
Safety classIII
Turn-on time
Safety outputsmax. 300 ms
Monitoring output OD
Output typep-switching, short circuit-proof
Output voltage0.8 x UB … UB V DC
Switching currentmax. 50 mA
Safety outputs FO1A / FO1B
Discrepancy timemax. 10 ms
Off-state current Irmax. 0.25 mA
Output typeSemiconductor outputs, p-switching, short circuit-proof
Output voltage
LOW U(FO1A) / U(FO1B)0 … 1 V DC
HIGH U(FO1A) / U(FO1B)UB-1.5V … UB V DC 
rated conditional short-circuit current100 A
Switching current
per safety output1 … 150 mA
Test pulse intervalmin. 100 ms
Test pulsesmax. 0.3 ms 
Utilization category
DC-1324V 150mA 

Mechanical values and environment

Cable ambient temperature (dynamic)-25 … +65 °C
Cable ambient temperature (static)-30 … +65 °C
ConnectionConnecting cable PUR, length 5 m
Degree of protectionIP67
Dynamic bending radius10 x cable diameter
Installation orientationany
Material
Rubber supportNBR 80 ±5 Shore
HousingPlastic, PBT
Mounting distance
between 2 switches or 2 actuatorsmin. 80 mm
Mounting typeSurface mounting on metal
Ready delay0.5 s
Shock and vibration resistanceaccording to EN 60947-5-3
Static bending radius5 x cable diameter
Switching frequencymax. 1 Hz
Tightening torque
Fixing screwsmax. 0.8 Nm

Reliability values according to EN ISO 13849-1

Mission time20 y
Monitoring of the guard position
Category4
Performance LevelPL e
PFHd4.1 x 10-9

Miscellaneous

Additional featureRubber support included
The following applies to the approval according to ULOperation only with UL Class 2 power supply or equivalent measures

In combination with actuator CES-A-BBN-C04-115271, CES-A-BBN-C04-EX-137527

Assured operating distance sao
Installation position A or B (front side)min. 6 mm
Installation position C or D (broad side)min. 10 mm
Assured release distance sar
in y directionmax. 60 mm
in x/z directionmax. 40 mm
Operating distance
Installation position C or D (broad side)11 mm
Installation position A or B (front side)15 mm
Switching hysteresis1 … 2 mm

In combination with actuator CES-A-BDN-06-104730

Assured operating distance sao
Installation position A or B (front side)min. 10 mm
Installation position C or D (broad side)min. 14 mm
Assured release distance sar
in x/z directionmax. 40 mm
in y directionmax. 60 mm
Operating distance
Installation position A or B (front side)15 mm
Installation position C or D (broad side)19 mm
Switching hysteresis1 … 2 mm

In combination with actuator CES-A-BDN-06-161742

Assured operating distance sao
Installation position Cmin. 16 (10,5 mm bei -30°C) mm
Installation position Amin. 10 (4,5 mm bei -30°C) mm
Assured release distance sar
Installation position Amax. 72 (auch bei -30°C) mm
Installation position Cmax. 77 (auch bei -30°C) mm
Operating distance
Installation position C23 (14 mm bei -30°C) mm
Installation position A26 (17 mm bei -30°C) mm
Switching hysteresis1 … 2 mm 

In combination with actuator CES-A-BBN-161502

Assured operating distance sao
in x direction/installation position C + Dmin. 15 (9,5 mm bei -30°C) mm
in z direction / installation position A + Bmin. 10 (4,5 mm bei -30°C) mm
Assured release distance sar
in x/z direction / installation position C + Dmax. 72 (auch bei -30°C) mm
in y direction / installation position A + Bmax. 77 (auch bei -30°C) mm
in y direction / installation position C + Dmax. 69 (auch bei -30°C) mm
in x/z direction / installation position A + Bmax. 63 (auch bei -30°C) mm
Operating distance
Installation position A + B30 (13 mm bei -30°C) mm
Installation position C + D25 (10 mm bei -30°C) mm
Switching hysteresis
in z direction / installation position A + B1 … 2 mm 
in x direction/installation position C + D1 … 2 mm 
Still not sure what you want?

We are here to help you, send us your details we will assist you to choose right product.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Know the part number Search here

Euchner CES-I-AP-U-C04-U05

Fill up the form and we will get back to you in few hours with right details. fill the form to help you better way.