Euchner EUCHNER CES-I-AS2A-M-C04-SC-120546

EUCHNER HBA-113815

EUCHNER CES-I-AS2A-M-C04-SC-120546

Euchner

EUCHNER CES-I-AS2A-M-C04-SC-120546

We are EUCHNER CES-I-AS2A-M-C04-SC-120546 product supplier in India

ORDER NO. 120546

Order number120546
Item designationCES-I-AS2A-M-C04-SC-120546
Gross weight0,071kg
Customs tariff number85365019

Safety switch CES-.-AS-C04 with AS-i connection, plug connector M8

  • Very compact design with 3 active faces
  • Integrated diagnostic LEDs
  • Category 4 / PL e according to EN ISO 13849-1
  • Plug connector M8, 3-pin
  • Multicode

Installation position

Permissible installation position

Multicode evaluation

Every suitable actuator is detected by the switch.

AS-Interface inputs

D0, D1, D2, D3Door monitoring

Evaluation is performed via a safety monitor.

LED function display

  • The STATE LED indicates the state of the switch.
  • The DIA LED indicates whether a fault has been detected in the switch.
  • The dual LED on the M8 plug connector indicates the state of the ASi bus.

Work area

Repeat accuracy R
according to EN 60947-5-2<=10

Electrical connection ratings

ASI data in
according to AS-i Safety at WorkD2 
according to AS-i Safety at WorkD1 
according to AS-i Safety at WorkD3 
according to AS-i Safety at WorkD0 
ASI slave type
according to ASI specification 3.0ID code: B
according to ASI specification 3.0AE code: 0
ASI operating currentmax. 50 mA
ASI voltage19 … 31.6 V
Rated insulation voltage Ui300 V
Rated impulse withstand voltage Uimp1.5 kV
Turn-on time
Safety outputsmax. 300 ms
Risk time according to EN 60947-5-3max. 260 ms
Safety classIII
Degree of contamination (external, according to EN 60947-1)3

Mechanical values and environment

Dimensions42 x 25 x 18
ConnectionM8 plug connector, 3-pin
Degree of protectionIP67
Material
Rubber supportNBR 80 ±5 Shore
HousingPlastic, PBT
Installation orientationany
Switching frequencymax. 1 Hz
Tightening torque
Plug connectormax. 0.3 Nm
Fixing screwsmax. 0.8 Nm
Mounting distance
between 2 switches or 2 actuatorsmin. 80 mm
Shock and vibration resistanceaccording to EN IEC 60947-5-3
Ambient temperature-25 … +65 °C

Reliability values acc. to EN ISO 13849-1

Mission time20 y
Monitoring of the guard position
Category4
Performance LevelPL e
PFHD4.5 x 10-9

Miscellaneous

The following applies to the approval according to ULOperation only with UL Class 2 power supply or equivalent measures

In combination with actuator CES-A-BBN-161502

Assured operating distances sao
Installation position A + B15 mm
Installation position C + D10 mm
Assured release distance sar
in x-/z direction / installation position C + Dmax. 63 mm
in y direction / installation position A + Bmax. 77 mm
in x/z direction / installation position A + Bmax. 69 mm
in y direction / installation position C + Dmax. 72 mm
Operating distance
Installation position A + B30 mm
Installation position C + D25 mm
Switching hysteresismin. 1 mm

In combination with actuator CES-A-BDN-06-104730, CES-A-BBN-C04-115271

Assured release distance sar
in y directionmax. 60 mm
in x/z directionmax. 40 mm
Switching hysteresis1 … 2 mm

In combination with actuator CES-A-BBN-C04-115271

Assured operating distances sao
Approach direction C or D (broad side)6 mm
Approach direction A or B (front side)10 mm
Operating distance
Approach direction C or D (broad side)11 mm
Approach direction A or B (front side)15 mm

In combination with actuator CES-A-BDN-06-104730

Assured operating distances sao
Approach direction C or D (broad side)min. 10 mm
Approach direction A or B (front side)min. 14 mm
Operating distance
Approach direction C or D (broad side)15 mm
Approach direction A or B (front side)19 mm
EUCHNER CES-I-AS2A-M-C04-SC-120546