XPSAV11113 Schneider Electric
This XPSAV safety modulemonitors emergency shutdown pushbuttons. It meets the requirements of Performance Level PL e/Category 4 conforming to standard EN/ISO 13849-1 and SILCL3 conforming to EN/IEC 61508 and EN/IEC 62061. It can be used for monitoring emergency stop circuits conforming to EN/ISO 13850 and EN/IEC 60204-1 standards. It also meets the safety requirements for the electrical monitoring of switches in protection devices conforming to EN/ISO 14119 standard. It has additional solid-state output for communication with PLCs about safety status of your process.
Enquire Now
XPSAV11113 Specification
Range of product | Preventa Safety automation |
---|---|
Product or component type | Preventa safety module |
Safety module name | XPSAV |
Safety module application | For emergency stop and switch monitoring |
Function of module | Emergency stop button with 2 NC contacts, monitored start Emergency stop monitoring 2-channel wiring Monitoring of a movable guard associated with 2 switches automatic start Emergency stop button with 1 NC contact, automatic start or unmonitored start Emergency stop monitoring 1-channel wiring |
Safety level | Can reach PL e/category 4 conforming to EN/ISO 13849-1 Can reach SILCL 3 conforming to EN/IEC 62061 |
Safety reliability data | DC > 99 % conforming to EN/ISO 13849-1 MTTFd = 75.8 years conforming to EN/ISO 13849-1 PFHd = 7.95E-9 1/h conforming to EN/IEC 62061 |
Type of start | Configurable |
Connections – terminals | Captive screw clamp terminals, 1 x 0.14…1 x 2.5 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 1 x 0.14…1 x 2.5 mm² solid with cable end, with double bezel Captive screw clamp terminals, 1 x 0.25…1 x 1.5 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 1 x 0.25…1 x 2.5 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 2 x 0.14…2 x 0.75 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 2 x 0.14…2 x 0.75 mm² solid with cable end, with double bezel Captive screw clamp terminals, 2 x 0.25…2 x 1 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 2 x 0.5…2 x 1.5 mm² flexible with cable end, with double bezel |
Output type | Relay instantaneous opening, 3 NO circuit(s), volt-free Relay time delay opening, 3 NO circuit(s), volt-free |
Number of additional circuits | 3 solid state outputs |
[Us] rated supply voltage | 24 V DC – 20…20 % |