Search
Close this search box.

WE HANDLE INQUIRIES THROUGH EMAIL MORE EFFICIENTLY

WE HANDLE INQUIRIES THROUGH EMAIL MORE EFFICIENTLY

Euchner EUCHNER CET3-AP-CRA-AH-50X-SA-122398

EUCHNER HBA-113815

EUCHNER CET3-AP-CRA-AH-50X-SA-122398

Euchner

EUCHNER CET3-AR-CRA-AH-50X-SG-109401

We are EUCHNER CET3-AP-CRA-AH-50X-SA-122398 product supplier in India

ORDER NO. 122398

Order number122398
Item designationCET3-AP-CRA-AH-50X-SA-122398
Gross weight1,273kg
Customs tariff number85365019

Non-contact safety switch CET-AP-…, M12

  • Safety switch with guard locking and integrated evaluation electronics
  • Locking force up to 6,500 N
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Category 4 / PL e according to EN ISO 13849-1
  • With 1 plug connector M12, 8-pin
  • Unicode
  • Door monitoring output
  • Indication of the door position by LED
  • Approach direction A (delivery state)

Approach direction

Horizontal

Can be adjusted in 90° steps

Safety switch

The device may be operated only in conjunction with the actuator CET-A-….

Important: The actuator must be ordered separately.

Unicode evaluation

Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can be taught-in. Only the last actuator taught-in is detected.

Solenoid operating voltage

  • DC 24 V +10%, -15%

Guard locking type

CET3Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid. The door position is also monitored. The door monitoring output OUT D is set to HIGH as soon as the actuator is above the extended plunger (state: door closed, guard locking not active). OUT output D also remains set when guard locking is active.

LED function display

State LEDStatus LED
DIA LEDDiagnostics LED
LED 1 rdilluminates when the solenoid is energized
LED 2 gnilluminates when door is closed

Additional connections

OUTMonitoring output (semiconductor)
OUT DDoor monitoring output

Category according to EN ISO 13849-1

Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:

  • Category 4 / PL e according to EN ISO 13849-1
  • The stated safety characteristics apply to any installation orientations of the safety switch.

Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated.

Work area

Repeat accuracy R
according to EN 60947-5-210 %

Electrical connection ratings

Power consumption
Solenoid11 W
Connecting cable30V DC, 2A 
Current consumption
ICM450 mA
IB80 mA
Fusing
external (operating voltage UB)0.25 … 8 A
external (solenoid operating voltage UCM)0.5 … 8 A
Operating voltage DC
LED24 V DC -15% V DC … +10% V DC
UB24 V DC -15% … +15% reverse polarity protected, regulated, residual ripple < 5%, PELV 
EMC protection requirementsaccording to EN IEC 60947-5-3
Utilization category
DC-1324V 200mA 
Solenoid operating voltage DC
UCM24 V DC -15% … +10% reverse polarity protected, regulated, residual ripple < 5%, PELV
Solenoid duty cycle100 %
Switching load
according to UL24V DC, Class 2 
Safety class
EN IEC 61140III
Test pulsesmax. 0.3 ms 
Degree of contamination (external, according to EN 60947-1)3
Monitoring output OUT D
Output typep-switching, short circuit-proof
Output voltage
OUT D0.8xUB … UB V DC
Switching current
OUT D1 … 50 mA
Switching delay from state changemax. 700 ms
Monitoring output OUT
Output typep-switching, short circuit-proof
Output voltage
OUT0.8xUB … UB V DC
Switching current
OUT1 … 50 mA
Switching delay from state changemax. 400 ms

Mechanical values and environment

Approach speedmax. 20 m/min
Connection1 plug connector M12, 8-pin
Degree of protectionIP67 
Ready delay1 s
Material
Rampstainless steel
Safety switch housingDie-cast aluminum
Mechanical life2 x 10⁶
Installation orientationany 
Switching frequencymax. 0.5 Hz
Degree of freedom X±5 mm
Degree of freedom Y±5 mm
Degree of freedom Z±4 mm
Shock and vibration resistanceaccording to EN IEC 60947-5-3
Ambient temperature
at UB = 24V DC-20 … +55 °C
Locking force Fmax6500 N
Locking force FZh5000 N 
Guard locking principleClosed-circuit current principle

Reliability values acc. to EN ISO 13849-1

Mission time20 y
Control of guard locking
CategoryDepending on external control of guard locking
Performance LevelDepending on external control of guard locking
PFHDDepending on external control of guard locking
Monitoring of guard locking and the guard position
Category
Any installation orientation4
Performance LevelPL e
PFHD
Any installation orientation3.1 x 10-9

Miscellaneous

The following applies to the approval according to ULOperation only with UL Class 2 power supply or equivalent measures; see operating instructions
Still not sure what you want?

We are here to help you, send us your details we will assist you to choose right product.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Know the part number Search here
EUCHNER CET3-AR-CRA-AH-50X-SG-109401

EUCHNER CET3-AP-CRA-AH-50X-SA-122398

Fill up the form and we will get back to you in few hours with right details. fill the form to help you better way.