Euchner EUCHNER CMS-E-ER

EUCHNER HBA-113815

EUCHNER CMS-E-ER

Euchner

EUCHNER CMS-E-ER

We are EUCHNER CMS-E-ER product supplier in India

ORDER NO. 099182

Order number099182
Item designationCMS-E-ER
Gross weight0,225kg
Customs tariff number85364110

Evaluation unit CMS-E-ER, 2 safety contacts, 1 auxiliary contact, 1 feedback loop can be connected

  • Up to 30 read heads can be connected
  • 2 safety contacts
  • 1 auxiliary contact
  • 1 feedback loop can be connected
  • Start automatic/monitored/not monitored

Functional description

The evaluation unit CMS-E-ER is suitable for the direct connection of up to 30 read heads.

Category/PL according to EN ISO 13849-1

  • Category 4/PL e with only one read head connected
  • Max. category 3/PL d with more than one connected read head

Notice:

At low approach speeds in the z direction, the time offset when switching the reed contacts must not be more than 0.6 ms.

Controls and indicators

LED indicator1 indicator LED Power (UB) and 2 status indicators for the read heads (K1/K2)

Electrical connection ratings

Breaking capacity (VA)
Safety contacts 13/14, 23/24max. 720 VA
Connection cross-section0.14 … 2.5 mm²
Current consumption
at DC 24V10 … 110 mA
Fusing
Protection internal (operating voltage UB)0.75 A Automatically resetting fuse PTC
External contact fuse (safety circuit) acc. to EN IEC 60269-14A gG
Rated insulation voltage Ui
AC250 V
Operating voltage
AC/DC-10% … 24 … +10% V 
Outputs
NumberTypeFunctionFootnote1Relay contacts, floatingAuxiliary contacts 31/322Relay contacts, floatingSafety contacts 13/14, 23/24
Switching current
Safety contacts 13/14, 23/2410 … 3000 mA at DC 24V
Auxiliary contacts 31/32max. 1500 mA at DC 24V
Switching voltage
Safety contacts 13/14, 23/24max. AC 240 V
Utilization category
AC-13A, 230V; 3A, 24V 
AC-150.9A , 240V and 0.9A , 24V 
DC-131.5A, 24V 
Risk time according to EN 60947-5-3max. 20 ms
Switching load
According to UL class 2Input: 24 V AC/DC; output: 30 V AC, 24 V DC
Degree of contamination (external, according to EN 60947-1)2

Mechanical values and environment

Approach direction
ConnectionConnection terminals
Degree of protectionTerminals IP20 / housing IP40
Material
HousingPolyamide PA6.6
Mechanical life10 x 10⁶
Mounting typeMounting rail 35 mm according to DIN EN 60715 TH35
Ambient temperature0 … +55 °C

Reliability values acc. to EN ISO 13849-1

Number of switching cycles
≤ 0.1A at 24V DC166000 1/y
≤ 1A at 24V DC70000 1/y
Mission time20 y 
Monitoring of the guard position with 1 read head
Category
Performance LevelPL e 
PFHD2.5 x 10-8 
Monitoring of the guard position with >1 read head
Category
Performance LevelPL d 
PFHD1.0 x 10-7 

Miscellaneous

in compliance withEN ISO 13849-1: 2015; EN ISO 13849-2:2012; EN 50178: 1997; EN 60204-1: 2006/A1: 2009; EN ISO 13850: 2015; EN 14119:2013; EN 6100-6-2: 2005; EN 6100-6-3: 2007/A1: 2011; EN 60947-5-3: 2013

In combination with read head CMS-R-CXC-03V, CMS-R-CXC-05V, CMS-R-CXC-05P, CMS-R-CXC-SC and actuator CMS-M-CA

Assured operating distances sao
with center offset m=0min. 6 mm 
Assured release distance sarmax. 14 mm 
Center offset
at s=3 mm read distance2,5 mm 

In combination with read head CMS-R-AXH-03V, CMS-R-AXH-05V, CMS-R-AXH-SC, CMS-R-AXH-05P and actuator CMS-M-AC

Assured operating distances sao
with center offset m=0min. 6 mm 
Assured release distance sarmax. 31 mm 
Center offset
at s=3 mm read distance2,5 mm 

In combination with read head CMS-R-BXI-03V, CMS-R-BXI-05V, CMS-R-BXI-SC, CMS-R-BXI-07P and actuator CMS-M-BD

Assured operating distances sao
with center offset m=0min. 3 mm 
Assured release distance sarmax. 12 mm 
Center offset
at s=3 mm read distance2,5 mm 

In combination with read head CMS-RH-BYB-03VL, CMS-RH-BYB-05VL and actuator CMS-MH-BB

Assured operating distances sao
with center offset m=0min. 6 mm 
Assured release distance sarmax. 13 mm 
Center offset
at s=3 mm read distance2,5 mm 

In combination with read head CMS-R-EXM-03V, CMS-R-EXM-05V, CMS-R-EXM-SC and actuator CMS-M-EF

Assured operating distances sao
with center offset m=0min. 6 mm 
Assured release distance sarmax. 17 mm 
Center offset
at s=3 mm read distance2,5 mm 

In combination with read head CMS-RH-AYA-03VL, CMS-RH-AYA-05VL and actuator CMS-MH-AA

Assured operating distances sao
with center offset m=0min. 10 mm 
Assured release distance sarmax. 20 mm 
Center offset
at s=3 mm read distance2,5 mm 
EUCHNER CMS-E-ER

EUCHNER CMS-E-ER