IFM IFM PN2094

ifm distributor in India

IFM PN2094

IFM

We are IFM Product supplier in India

Article No – PN-010-RER14-MFRKG/US/ /V

Pressure sensor with display

  • Two switching outputs, one of them programmable as IO-Link and one as analogue output
  • Red/green display for clear identification of the acceptable range
  • The process connection can be rotated for optimum alignment
  • With long-term stability thanks to high overload protection
  • Robust design for use in harsh industrial environments

Product characteristics

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Measuring range-1…10 bar-14.6…145 psi-0.1…1 MPa
Process connectionthreaded connection G 1/4 internal thread (DIN EN ISO 1179-2)

Application

Special featureGold-plated contacts
Measuring elementceramic-capacitive pressure measuring cell
Applicationfor industrial applications
Medialiquids and gases
Medium temperature [°C]-25…80
Min. bursting pressure150 bar2175 psi15 MPa
Pressure rating75 bar1087 psi7.5 Mpa
Vacuum resistance [mbar]-1000
Type of pressurerelative pressure; vacuum

Electrical data

Operating voltage [V]18…30 DC; (to SELV/PELV)
Current consumption [mA]< 35
Min. insulation resistance [MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]0.3
Integrated watchdogyes

Inputs / outputs

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1

Outputs

Total number of outputs2
Output signalswitching signal; analogue signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]2
Permanent current rating of switching output DC [mA]250
Switching frequency DC [Hz]< 500
Number of analogue outputs1
Analogue current output [mA]4…20; (scalable 1:5)
Max. load [Ω]500
Analogue voltage output [V]0…10; (scalable 1:5)
Min. load resistance [Ω]2000
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes

Measuring/setting range

Measuring range-1…10 bar-14.6…145 psi-0.1…1 MPa
Analogue start point-1…8 bar-14.6…116 psi-0.1…0.8 MPa
Analogue end point1…10 bar14.6…145 psi0.1…1 MPa

Factory setting / CMPT = 2

Set point SP-0.94…10 bar-13.6…145 psi-0.094…1 MPa
Reset point rP-0.98…9.96 bar-14.2…144.4 psi-0.098…0.996 MPa
Min. difference between SP and rP0.06 bar0.6 psi0.006 MPa
In steps of0.02 bar0.2 psi0.002 MPa

Status_B High Resolution / CMPT = 3

Set point SP-0.94…10 bar-13.6…145 psi-0.094…1 MPa
Reset point rP-0.98…9.96 bar-14.2…144.4 psi-0.098…0.996 MPa
Min. difference between SP and rP0.05 bar0.6 psi0.005 MPa
In steps of0.01 bar0.1 psi0.001 MPa

Accuracy / deviations

Switch point accuracy [% of the span]< ± 0,4; (Turn down 1:1)
Repeatability [% of the span]< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation [% of the span]< ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation [% of the span]< ± 0,1; (Turn down 1:1)
Long-term stability [% of the span]< ± 0,05; (Turn down 1:1; per 6 months)
Temperature coefficient zero point [% of the span / 10 K]< ± 0,2; (-0…80 °C)
Temperature coefficient span [% of the span / 10 K]< ± 0,2; (-0…80 °C)
Notes on the accuracy / deviationswitch point accuracy, linearity error under DNV GL: < ± 1%: < ± 1%

Response times

Response time [ms]< 1.5
Delay time programmable dS, dr [s]0…50
Damping process value dAP [s]0…4
Damping for the analogue output dAA [s]0…4
Max. response time analogue output [ms]3

Software / programming

Parameter setting optionshysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output

Interfaces

Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
SIO modeyes
Required master port typeA; (when pin 2 not connected: B)
Supported DeviceIDsType of operationDeviceIDFactory setting / CMPT = 2463Status_B High Resolution / CMPT = 3974
NoteFor further information please see the IODD PDF file under “Downloads”

Factory setting / CMPT = 2

ProfilesSmart Sensor: Process Data Variable; Device Identification, Device Diagnosis
Min. process cycle time [ms]2.3
IO-Link resolution pressure [bar]0.01
IO-Link process data (cyclical)functionbit lengthpressure14binary switching information2
IO-Link functions (acyclical)application specific tag

Status_B High Resolution / CMPT = 3

ProfilesSmart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000)
Min. process cycle time [ms]3
IO-Link resolution pressure [bar]0.005
IO-Link process data (cyclical)functionbit lengthpressure16device status4binary switching information2
IO-Link functions (acyclical)application specific tag

Operating conditions

Ambient temperature [°C]-25…80
Storage temperature [°C]-40…100
ProtectionIP 65; IP 67

Tests / approvals

EMCDIN EN 61000-6-2DIN EN 61000-6-3
Shock resistanceDIN EN 60068-2-2750 g (11 ms)
Vibration resistanceDIN EN 60068-2-620 g (10…2000 Hz)
MTTF [years]138
UL approvalUL Approval no.J012
Pressure Equipment DirectiveSound engineering practice; can be used for group 2 fluids; group 1 fluids on request

Mechanical data

Weight [g]239
Materialsstainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC
Materials (wetted parts)stainless steel (1.4404 / 316L); Al2O3 (ceramics); FKM
Min. pressure cycles100 million
Tightening torque [Nm]25…35; (recommended tightening torque; depends on lubrication, seal and pressure rating)
Process connectionthreaded connection G 1/4 internal thread (DIN EN ISO 1179-2)
Restrictor element integratedno (can be retrofitted)

Displays / operating elements

DisplayDisplay unit3 x LED, green (bar, psi, MPa)switching status2 x LED, yellowmeasured valuesalphanumeric display, red/green 4-digit

Remarks

Pack quantity1 pcs.

Electrical connection

ConnectionConnector: 1 x M12; coding: A; Contacts: gold-plated

IFM PN2094