Part Number – 101187882Â
- Large wiring compartment
- Emergency exit, cover-side
- cable entries 4 M 16 x 1.5
- Thermoplastic enclosure
- Double-insulated
- Interlock with protection against incorrect locking.
- 130 mm x 90 mm x 30 mm
- 6 Contacts
- Long life
Ordering data
| EAN (European Article Number) | 4030661357126 |
| eCl@ss number, Version 9.0 | 27-27-26-03 |
| eCl@ss number, Version 11.0 | 27-27-26-03 |
Approval – Standards
| Certificates | cULusCCCEAC |
General data
| Standards | EN 60947-5-1BG-GS-ET-19 |
| Coding level according to ISO 14119 | Low |
| Active principle | electromechanical |
| Enclosure material | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
| Material of the contacts, electrical | Silver |
| Gross weight | 433.5 g |
General data – Features
| Power to unlock | Yes |
| Emergency exit | Yes |
| Manual release | Yes |
| Number of actuating directions | 3 |
| Number of auxiliary contacts | 2 |
| Number of safety contacts | 4 |
Safety appraisal
| Standards | EN ISO 13849-1 |
| Mission Time | 20 Year(s) |
Safety appraisal – Safety outputs
| B10d Normally-closed contact (NC) | 2,000,000 Operations |
| B10d Normally open contact (NO) | 1,000,000 Operations |
Mechanical data
| Mechanical life, minimum | 1,000,000 Operations |
| Actuating play in direction of actuation | 5.5 mm |
| Clamping force in accordance with ISO14119 Fzh | 2,000 N |
| Latching force | 30 N |
| positive break travel | 10 mm |
| Positive break force, minimum | 20 N |
| Actuating speed, maximum | 2 m/s |
Mechanical data – Connection technique
| Terminal Connector | Cage clamps |
| Cable section, minimum | 1 x 0.25 mm² |
| Cable section, maximum | 1 x 1.5 mm² |
| Note (Cable section) | All indications about the cable section are including the conductor ferrules. |
Mechanical data – Dimensions
| Length of sensor | 30 mm |
| Width of sensor | 130 mm |
| Height of sensor | 90 mm |
Ambient conditions
| Degree of protection | IP67 to EN 60529 |
| Ambient temperature, minimum | -25 °C |
| Ambient temperature, maximum | +60 °C |
Ambient conditions – Insulation value
| Rated insulation voltage Ui | 250 V |
| Rated impulse withstand voltage Uimp | 4 kV |
Electrical data
| Thermal test current | 6 A |
| Rated control voltage | 24 VAC/DC |
| Required rated short-circuit current to EN 60947-5-1 | 1,000 A |
| Electrical power consumption, maximum | 10 W |
| Switching element | NO contact, NC contact |
| Switching principle | Creep circuit element |
| Switching frequency | 1,000 /h |
Electrical data – Safety contacts
| Voltage, Utilisation category AC15 | 230 VAC |
| Current, Utilisation category AC-15 | 4 A |
| Voltage, Utilisation category DC13 | 24 VDC |
| Current, Utilisation category DC13 | 2.5 A |
Electrical data – Auxiliary contacts
| Voltage, Utilisation category AC15 | 230 VAC |
| Current, Utilisation category AC-15 | 4 A |
| Voltage, Utilisation category DC13 | 24 VDC |
| Current, Utilisation category DC13 | 2.5 A |
Other data
| Note (applications) | sliding safety guardremovable guardhinged safety guard |
Scope of delivery
| Included in delivery | Actuators must be ordered separately. |
Notes
| Note (Emergency exit) | The emergency exit is used where an intervention in an already locked hazardous area is requiredEmergency exit by pressing the red push buttonResetting by pulling on the latched buttonTop-side (ordering suffix -TD) or rear-side (ordering suffix -TU) mounting possible |