094800
Read head CEM-A-LE05… with guard locking without guard lock monitoring with remanence
- Read head with guard locking without guard lock monitoring
- Locking force 650 N
- With remanence
- Up to category 4 according to EN ISO 13849-1
- Two safety screws M5x16 included
Note assured release distance sar = 20 mm for internal component failure. Safety outputs are reliably switched off.
Technical Data
Work area
Assured operating distance sao | |
with center offset m=0 | min. 2 mm |
Assured release distance sar | max. 20 mm |
Center offset | -2.5 … +2.5 mm |
Switching hysteresis | |
with center offset m=0 | 0.7 mm |
Electrical connection ratings
Current consumption | |
UB | 100 mA |
Operating voltage DC | |
UCM | 24 V DC -15% … +10% |
Power consumption | 2.5 W |
Solenoid duty cycle | 100 % |
Mechanical values and environment
Adhesive force | |
due to remanence | 10 N -25% … +25% |
Ambient temperature | -25 … +50 °C |
Cable length | max. 25 m |
Connection | |
X3, read head | Plug connector M8x1, 3-pin, male (with snap-action/screw terminal) |
X1, solenoid (yellow LED integrated in the plug) | Plug connector M8x1, 4-pin, male (with snap-action/screw terminal) |
Degree of protection | IP67 |
Guard locking principle | Open-circuit current principle |
Installation orientation | any |
Locking force F | |
(not monitored, in axial direction) at UCM=24V | 650 N |
Material | |
Housing | Die-cast aluminum |
Read head | Plastic (PPS) |
Solenoid | Steel, nickel plated |
Mechanical life | |
in case of use as door stop, and 1 Joule impact energy | 1 x 10⁶ |
Switching frequency | |
Solenoid | max. 1 Hz |