116503
Non-contact safety switches CES-I-AP-.- C04-…, flying lead
- Safety switch with integrated evaluation electronics
- No series connection
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Category 4 / PL e according to EN ISO 13849-1
- Three active faces
- Connecting cable PUR, 5 m, flying lead
- Unicode
- Monitoring output OD
Installation position
Permissible installation position
Unicode evaluation
Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can be taught-in. Only the last actuator taught-in is detected.
Category according to EN 13849-1
Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
- Category 4/PL e according to EN 13849-1
Important: To achieve the stated category according to EN ISO 13849-1, both safety outputs (FO1A and FO1B) must be evaluated.
LED indicator
STATE | Status LED |
DIA | Diagnostic LED |
Terminal assignment
Designation | Function | Conductor coloring of connecting cable |
---|---|---|
UB | Power supply, DC 24 V | BN |
FO1A | Safety output, channel 1 | WH |
0V | Ground, DC 0 V | BU |
FO1B | Safety output, channel 2 | BK |
OD | Monitoring output | GY |
Technical Data
Work area
Repeat accuracy R | |
according to EN 60947-5-2 | <= 10 |
Electrical connection ratings
Current consumption | |
no load on outputs | max. 35 mA |
Degree of contamination (external, according to EN 60947-1) | 3 |
EMC protection requirements | according to EN IEC 60947-5-3 |
Fusing | |
external (operating voltage) | 0.25 … 8 A |
Operating voltage DC | |
UB | 24 V DC -15% … +15% regulated, residual ripple 5%, PELV |
Rated impulse withstand voltage Uimp | 1.5 kV |
Rated insulation voltage Ui | 300 V |
Risk time according to EN 60947-5-3 | max. 260 ms |
Safety class | III |
Turn-on time | |
Safety outputs | max. 300 ms |
Monitoring output OD | |
Output type | p-switching, short circuit-proof |
Output voltage | 0.8 x UB … UB V DC |
Switching current | max. 50 mA |
Safety outputs FO1A / FO1B | |
Discrepancy time | max. 10 ms |
Off-state current Ir | max. 0.25 mA |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
LOW U(FO1A) / U(FO1B) | 0 … 1 V DC |
HIGH U(FO1A) / U(FO1B) | UB-1.5V … UB V DC |
rated conditional short-circuit current | 100 A |
Switching current | |
per safety output | 1 … 150 mA |
Test pulse interval | min. 100 ms |
Test pulses | max. 0.3 ms |
Utilization category | |
DC-13 | 24V 150mA |
Mechanical values and environment
Cable ambient temperature (dynamic) | -25 … +65 °C |
Cable ambient temperature (static) | -30 … +65 °C |
Connection | Connecting cable PUR, length 5 m |
Degree of protection | IP67 |
Dynamic bending radius | 10 x cable diameter |
Installation orientation | any |
Material | |
Rubber support | NBR 80 ±5 Shore |
Housing | Plastic, PBT |
Mounting distance | |
between 2 switches or 2 actuators | min. 80 mm |
Mounting type | Surface mounting on metal |
Ready delay | 0.5 s |
Shock and vibration resistance | according to EN 60947-5-3 |
Static bending radius | 5 x cable diameter |
Switching frequency | max. 1 Hz |
Tightening torque | |
Fixing screws | max. 0.8 Nm |
Reliability values according to EN ISO 13849-1
Mission time | 20 y |
Monitoring of the guard position | |
Category | 4 |
Performance Level | PL e |
PFHd | 4.1 x 10-9 |
Miscellaneous
Additional feature | Rubber support included |
The following applies to the approval according to UL | Operation only with UL Class 2 power supply or equivalent measures |
In combination with actuator CES-A-BBN-C04-115271, CES-A-BBN-C04-EX-137527
Assured operating distance sao | |
Installation position A or B (front side) | min. 6 mm |
Installation position C or D (broad side) | min. 10 mm |
Assured release distance sar | |
in y direction | max. 60 mm |
in x/z direction | max. 40 mm |
Operating distance | |
Installation position C or D (broad side) | 11 mm |
Installation position A or B (front side) | 15 mm |
Switching hysteresis | 1 … 2 mm |
In combination with actuator CES-A-BDN-06-104730
Assured operating distance sao | |
Installation position A or B (front side) | min. 10 mm |
Installation position C or D (broad side) | min. 14 mm |
Assured release distance sar | |
in x/z direction | max. 40 mm |
in y direction | max. 60 mm |
Operating distance | |
Installation position A or B (front side) | 15 mm |
Installation position C or D (broad side) | 19 mm |
Switching hysteresis | 1 … 2 mm |
In combination with actuator CES-A-BDN-06-161742
Assured operating distance sao | |
Installation position C | min. 16 (10,5 mm bei -30°C) mm |
Installation position A | min. 10 (4,5 mm bei -30°C) mm |
Assured release distance sar | |
Installation position A | max. 72 (auch bei -30°C) mm |
Installation position C | max. 77 (auch bei -30°C) mm |
Operating distance | |
Installation position C | 23 (14 mm bei -30°C) mm |
Installation position A | 26 (17 mm bei -30°C) mm |
Switching hysteresis | 1 … 2 mm |
In combination with actuator CES-A-BBN-161502
Assured operating distance sao | |
in x direction/installation position C + D | min. 15 (9,5 mm bei -30°C) mm |
in z direction / installation position A + B | min. 10 (4,5 mm bei -30°C) mm |
Assured release distance sar | |
in x/z direction / installation position C + D | max. 72 (auch bei -30°C) mm |
in y direction / installation position A + B | max. 77 (auch bei -30°C) mm |
in y direction / installation position C + D | max. 69 (auch bei -30°C) mm |
in x/z direction / installation position A + B | max. 63 (auch bei -30°C) mm |
Operating distance | |
Installation position A + B | 30 (13 mm bei -30°C) mm |
Installation position C + D | 25 (10 mm bei -30°C) mm |
Switching hysteresis | |
in z direction / installation position A + B | 1 … 2 mm |
in x direction/installation position C + D | 1 … 2 mm |