Product characteristics |
---|
Measuring range [m] | 0.2…3.5; (black glossy surfaces) |
Communication interface | IO-Link |
Laser protection class | 2 |
Housing | rectangular |
Dimensions [mm] | 59 x 42 x 52 |
Electrical data |
---|
Operating voltage [V] | 18…30 DC |
Current consumption [mA] | < 150 |
Protection class | III |
Reverse polarity protection | yes |
Typ. lifetime [h] | 50000 |
Inputs / outputs |
---|
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
Outputs |
---|
Total number of outputs | 2 |
Electrical design | PNP |
Number of digital outputs | 2 |
Output function | normally open / normally closed; (programmable) |
Max. current load per output [mA] | 200 |
Number of analogue outputs | 1 |
Analogue current output [mA] | 4…20; (IEC 61131-2) |
Max. load [Ω] | 250 |
Analogue voltage output [V] | 0…10; (IEC 61131-2) |
Min. load resistance [Ω] | 5000 |
Short-circuit protection | yes |
Type of short-circuit protection | pulsed |
Overload protection | yes |
Detection zone |
---|
Max. light spot width [mm] | 6 |
Max. light spot height [mm] | 6 |
Light spot dimensions refer to | 3,5 m |
Background suppression [m] | 0…4 |
Measuring/setting range |
---|
Measuring range [m] | 0.2…3.5; (black glossy surfaces) |
Sampling rate [Hz] | 1…50; (preset: 5) |
|