Product characteristics |
---|
Number of inputs and outputs | Number of digital outputs: 4 |
Factory setting | 2 switching outputs level (OUT1, OUT2); 2 switching outputs temperature (OUT3, OUT4); mineral oils |
Probe length L [mm] | 472 |
Application |
---|
Media | hydrous coolants; oils; oil-based media; water; media similar to water |
Dielectric constant of the medium | > 2 |
Cannot be used for | extremely conductive media; adhering media; granulates; bulk material; acids; alkali |
Tank pressure [bar] | 0.5; (when mounting with mounting accessories: E43001 – E43007, E43019) |
Coolants |
---|
Medium temperature [°C] | 0…35; (with climatic tube E43101 35…60 °C) |
Oil |
---|
Medium temperature [°C] | 0…70 |
Medium temperature short time [°C] | 0…90; (< 1 h) |
Water |
---|
Medium temperature [°C] | 0…35; (with climatic tube E43101 35…60 °C) |
Electrical data |
---|
Operating voltage [V] | 18…30 DC |
Current consumption [mA] | < 50 |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | < 3 |
Inputs / outputs |
---|
Number of inputs and outputs | Number of digital outputs: 4 |
Outputs |
---|
Total number of outputs | 4 |
Output signal | switching signal; IO-Link |
Electrical design | PNP/NPN |
Number of digital outputs | 4 |
Output function | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] | 2.5 |
Permanent current rating of switching output DC [mA] | 200 |
Short-circuit protection | yes |
Type of short-circuit protection | thermal, pulsed |
Overload protection | yes |
|