ORDER NO. 088257
Order number | 088257 |
Item designation | TP4-4141A024SEM4AS1 |
Gross weight | 0,47kg |
Customs tariff number | 85365019 |
Safety switch TP AS1, plug connector M12 (closed-circuit current principle)
- Auxiliary release on the front
- Increased horizontal overtravel
- Optionally without guard lock monitoring
Guard locking types
TP3 | Closed-circuit current principle, guard locking by spring force. Release by control of AS-i output 0. |
TP4 | Open-circuit current principle, guard locking by control of AS-i output 0. Release by spring force. |
Control of the guard locking solenoid
The guard locking solenoid is controlled by the control system via AS-Interface bus bit D0. In addition, the 24V connection can be switched safely.
AS-Interface inputs, version AS1
D0, D1 | Door monitoring contact SK |
D2, D3 | Solenoid monitoring contact ÜK |
AS-Interface inputs, version AS1
D0, D1 | Door monitoring contact SK 1 |
D2, D3 | Door monitoring contact SK 2 |
Evaluation is performed via a safety monitor.
AS-Interface outputs
D0 | Guard locking solenoid |
D1 | LED red |
D2 | LED green |
LED function display
- The Power LED indicates the operating voltage on the bus.
- The Fault LED indicates if a fault has been detected on the AS-Interface bus.
- The green and the red LEDs can be controlled as required by the control system via the bus using bits D1 and D2.
Auxiliary release
This is used for releasing the guard locking with the aid of a tool. To protect against tampering, the auxiliary release is sealed with sealing lacquer.
Electrical connection ratings
ASI data in | |
according to AS-i Safety at Work | D0, D1, D2, D3 |
ASI data out | |
LED red | D1 |
ASI slave type | |
according to ASI specification 2.1 | ID code: B |
ASI operating current | max. 45 mA |
ASI auxiliary voltage | |
IEC 60742, PELV | 24 V -15% … +10% |
ASI auxiliary current | 300 mA |
ASI voltage | 22.5 … 30 … 31.6 V |
Solenoid duty cycle | 100 % |
Mechanical values and environment
Approach speed | max. 20 m/min |
Number of door position positively driven contacts | |
according to AS-i Safety at Work | 1 |
Number of guard lock monitoring positively driven contacts | |
according to AS-i Safety at Work | 1 D2,D3 |
Extraction force | 20 N |
Material | |
Housing | Reinforced thermoplastic |
Actuation frequency | max. 1200 1/h |
Mechanical life | 1 x 10⁶ |
Installation orientation | any |
Switching principle | Slow-action switching contact |
Retention force | 10 N |
Ambient temperature | -20 … +55 °C |
In combination with actuator ACTUATOR-P-GT
Horizontal insertion depth | 28 mm |
Vertical insertion depth | 29.5 mm |
Horizontal overtravel | 2 mm |
Vertical overtravel | 1.5 mm |
In combination with actuator ACTUATOR-P-GNT
Horizontal insertion depth | 28 mm |
Horizontal overtravel | 7 mm |