Euchner EUCHNER CES-A-C5H-01-EX

EUCHNER HBA-113815

EUCHNER CES-A-C5H-01-EX

Euchner

EUCHNER CES-A-C5H-01-EX

We are EUCHNER CES-A-C5H-01-EX product supplier in India

ORDER NO. 097945

Order number097945
Item designationCES-A-C5H-01-EX
Gross weight0,545kg
European Article Number (EAN)4047048006355
Customs tariff number85365019

Non-contact safety switch CES-A-C5… ATEX

  • ATEX version
  • With protective plate
  • Suitable for use in zones 2 and 22 (gases and dusts)
  • Safety switches as interlocking device of type 4
  • Safety switch with integrated evaluation electronics
  • Pulsed signals can be switched
  • 2 safety outputs (semiconductor outputs)
  • Up to category 4 / PL e according to EN ISO 13849-1

Approach direction

Can be adjusted in 90° steps

Protective plate

A protective plate included protects the safety switch against impacts on the housing and the ingress of an explosive atmosphere.

Unicode evaluation

Each actuator is highly coded (unicode). The evaluation unit detects only actuators that have been taught-in. Additional actuators can be taught-in.

Category according to EN ISO 13849-1

Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:

  • CES-A-C5H-01, category 4 / PL e according to EN ISO 13849-1

LED indicator

STATEStatus LED
OUT/ERRORSafety outputs status / diagnostics LED (combined)

Additional connections

OUTMonitoring output (semiconductor)

Attention:

The actuating range may vary depending on the substrate material and installation situation.

Typical actuating range
(only in combination with actuators CES-A-BBA, CES-A-BCA)

<p>Typical actuating range<br>(only in combination with actuators CES-A-BBA, CES-A-BCA)</p>

For a side approach direction for the actuator and safety switch, a minimum distance of s = 4 mm must be maintained so that the actuating range of the side lobes is not entered. Typical actuating range
(only in combination with actuator CES-A-BPA)For a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm must be maintained so that the actuating range of the side lobes is not entered.

Work area

Repeat accuracy R
according to EN 60947-5-2max. 10 %

Controls and indicators

LED indicator
Safety outputs status / diagnostics LED (combined)
Status LED

Electrical connection ratings

Current consumption80 mA
Fusing
(external) operating voltage0.25 … 8 A
Rated insulation voltage Ui300 V 
Rated impulse withstand voltage Uimp1.5 kV
Operating voltage DC21 … 24 … 27 V DC regulated, residual ripple < 5%
EMC protection requirementsaccording to EN 60947-5-3
Degree of contamination (external, according to EN 60947-1)3
Monitoring output OUT
Output typeSemiconductor output, p-switching, short circuit-proof
Output currentmax. 20 mA
Output voltage0.8 x UB … UB V DC
Safety outputs LA / LB
Output typeSemiconductor outputs, p-switching, short circuit-proof, electrically decoupled 
Fusing
external, safety circuit U(+LA) / U(+LB)0.1 A medium slow-blow
Output current
per safety output1 … 100 mA
rated conditional short-circuit currentmax. 100 A
Discrepancy time
(between the operating points of both safety outputs)max. 120 ms
Output voltage
HIGH U(LB)U(+LB) – 1.5 … U(+LB) V DC
HIGH U(LA)U(+LA) – 1.5 … U(+LA) V DC
LOW U(LA) / U(LB)0 … 1 V DC
Switching load
according to ULmax. DC 24 V, Class 2
Power supply output load
U(+LA) / U(+LB)18 … 24 … 27 V DC

Mechanical values and environment

Dimensionsaccording to EN 60947-5-2
ConnectionM12 plug connector, 8-pin; shield can be connected
Degree of protectionIP65/IP67
Ready delaymax. 3 s 
Material
HousingPlastic PBT V0 GF30
Installation orientationany
Switching frequencymax. 1 Hz
Reaction time
after change in the actuation statusmax. 180 ms 
Tightening torque
Fixing screws, housingmax. 1 Nm
Screws, read head mounting bracketmax. 0.6 Nm
Mounting distance
between 2 read heads or 2 actuatorsmin. 80 mm
Ambient temperature
at UB = 24 V DC-20 … +50 °C
Dwell timemin. 0.5 s 

Reliability values acc. to EN ISO 13849-1

Diagnostic Coverage (DC)99 %
Mission time20 y
Monitoring of the guard position
Category
Performance LevelPL e
PFHD3.7 x 10-9

Miscellaneous

Explosion protection
incl. cover hoodII3G Ex ic ec IIB T5 Gc X / II3D Ex ic tc IIIC T90°C Dc X
The following applies to the approval according to ULOperation only with UL Class 2 power supply or equivalent measures

In combination with actuator CES-A-BBA-EX-098158

Actuator distance s
Minimum distance for side approach directionmin. 4 mm
Assured operating distances sao
with center offset m=0min. 18 mm 
Assured release distance sarmax. 40 mm
Operating distance
with center offset m=020 mm 
Switching hysteresis2 … 3 mm 

In combination with actuator CES-A-BPA-EX-102125

Actuator distance s
Minimum distance for side approach directionmin. 6 mm
Assured operating distances sao
with center offset m=0min. 15 mm 
Assured release distance sarmax. 58 mm
Operating distance
with center offset m=022 mm 
Switching hysteresis1 … 2 mm 
Still not sure what you want?

We are here to help you, send us your details we will assist you to choose right product.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Know the part number Search here
EUCHNER CES-A-C5H-01-EX

EUCHNER CES-A-C5H-01-EX

Fill up the form and we will get back to you in few hours with right details. fill the form to help you better way.