Euchner EUCHNER CES-AR-C01-AH-SA

EUCHNER HBA-113815

EUCHNER CES-AR-C01-AH-SA

Euchner

EUCHNER CES-AR-C01-AH-SA

We are EUCHNER CES-AR-C01-AH-SA product supplier in India

ORDER NO. 098941

Order number098941
Item designationCES-AR-C01-AH-SA
Gross weight0,19kg
European Article Number (EAN)4047048005433
Customs tariff number85365019

Non-contact safety switch CES-AR-C01…

  • Safety switch with integrated evaluation electronics
  • Up to 20 switches in series
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Category 4 / PL e according to EN ISO 13849-1
  • Unicode

Approach direction

Can be adjusted in 90° steps

Short circuit monitoring

The switch generates its own clock signal on the output lines OA/OB. Pay attention to this aspect when connecting to control systems and relays.

Unicode evaluation

Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can be taught-in.

Only the last actuator taught-in is detected.

Category according to EN 13849-1

Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:

  • Category 4/PL e according to EN 13849-1

Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated.

LED indicator

STATEStatus LED
DIADiagnostics LED

Additional connections

OUTMonitoring output (semiconductor)
RSTReset input

Typical actuating range

With actuators CES-A-BBA and CES-A-BCA

<p>With actuators CES-A-BBA and CES-A-BCA</p>

For a side approach direction for the actuator and safety switch, a minimum distance of s = 4 mm must be maintained so that the actuating range of the side lobes is not entered.With actuator CES-A-BPAFor a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm must be maintained so that the actuating range of the side lobes is not entered.

Work area

Repeat accuracy R
according to EN 60947-5-2<= 10

Electrical connection ratings

Current consumption
no load on outputsmax. 50 mA
Fusing
external (operating voltage)0.25 … 8 A
Rated insulation voltage Ui300 V 
Rated impulse withstand voltage Uimp1.5 kV
Operating voltage DC
UB24 V DC -15% … +15% reverse polarity protected, regulated, residual ripple < 5%, PELV
Turn-on time
Safety outputsmax. 400 ms
EMC protection requirementsaccording to EN IEC 60947-5-3
Risk time according to EN 60947-5-3
Single devicemax. 260 ms
Risk time according to EN 60947-5-3, extension for each additional devicemax. 5 ms
Safety classIII
Degree of contamination (external, according to EN 60947-1)3
Monitoring output OUT
Output typep-switching, short circuit-proof
Output voltage0.8 x UB … UB V DC 
Switching currentmax. 200 mA
Safety outputs OA / OB
Output typeSemiconductor outputs, p-switching, short circuit-proof
rated conditional short-circuit currentmax. 100 A
Discrepancy timemax. 10 ms
Output voltage
HIGH U(OA,OB)UB-1.5 … UB V DC 
LOW U(OA,OB)0 … 1 V DC
Switching current
per safety output1 … 400 mA
Utilization category
DC-1324V 400mA 
Off-state current Irmax. 0.25 mA
Test pulsesmax. 1 ms

Mechanical values and environment

ConnectionM12 plug connector, 8-pin
Degree of protectionIP67
Ready delay10 s
Material
HousingPlastic, PBT
Installation orientationany
Switching frequencymax. 1 Hz
Tightening torque
Fixing screwsmax. 1 Nm
Mounting distancemin. 40 mm
Shock and vibration resistanceaccording to EN IEC 60947-5-3
Ambient temperature-20 … +55 °C

Reliability values acc. to EN ISO 13849-1

Mission time20 y
Monitoring of the guard position
Category4
Performance LevelPL e
PFHD2.1 x 10-9

Miscellaneous

The following applies to the approval according to ULOperation only with UL Class 2 power supply or equivalent measures

In combination with actuator CES-A-BDA-18-156935

Assured operating distances saomin. 10 mm 
Assured release distance sarmax. 45 mm 
Operating distance19 mm 
Switching hysteresis1 … 3 mm 
Mounting distance

In combination with actuator CES-A-BBA-071840

Assured operating distances saomin. 15 mm 
Assured release distance sarmax. 45 mm 
Operating distance18 mm
Switching hysteresis1 … 3 mm 
Mounting distance

In combination with actuator CES-A-BRN-100251

Assured operating distances saomin. 20 mm 
Assured release distance sarmax. 75 mm
Operating distance27 mm
Switching hysteresis3 mm 
Mounting distance

In combination with actuator CES-A-BPA-098775

Assured operating distances saomin. 18 mm
Assured release distance sarmax. 58 mm
Operating distance22 mm 
Switching hysteresis1 … 2 mm
Mounting distance
Still not sure what you want?

We are here to help you, send us your details we will assist you to choose right product.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Know the part number Search here
EUCHNER CES-AR-C01-AH-SA

EUCHNER CES-AR-C01-AH-SA

Fill up the form and we will get back to you in few hours with right details. fill the form to help you better way.