Euchner EUCHNER CES-AP-CL2-CH-SB-106551

EUCHNER HBA-113815

EUCHNER CES-AP-CL2-CH-SB-106551

Euchner

EUCHNER CES-AP-CL2-CH-SB-106551

We are EUCHNER CES-AP-CL2-CH-SB-106551 product supplier in India

ORDER NO. 106551

Order number106551
Item designationCES-AP-CL2-CH-SB-106551
Gross weight0,099kg
Customs tariff number85365019

Non-contact safety switch CES-AP-CL2-… , M12, PUR

  • Safety switch with integrated evaluation electronics
  • No series connection
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Door hinge left
  • Category 4 / PL e according to EN ISO 13849-1
  • Connecting cable PUR, 0.2 m, plug connector M12, 5-core
  • Multicode
  • Two safety screws M4x14 included

Short circuit monitoring

The switch generates its own clock signal on the output lines OA/OB.

Pay attention to this aspect when connecting to control systems and relays.

Multicode evaluation

Every suitable actuator is detected by the switch.

Category according to EN 13849-1

Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:

  • Category 4/PL e according to EN 13849-1

Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated.

LED indicator

STATEStatus LED
DIADiagnostics LED

Additional connection

OUTMonitoring output (semiconductor)

Approach directions

<p>Approach directions</p>

Typical actuating range

(Actuator CES-A-BLN… in conjunction with safety switch CES-AP-C.2-… in case of mounting on plastic)

For a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm must be maintained so that the actuating range of the side lobes is not entered.

Attention:

The actuating range may vary depending on the substrate material and installation situation.

Work area

Repeat accuracy R
according to EN 60947-5-2<= 10

Electrical connection ratings

Current consumptionmax. 30 mA 
Fusing
external (operating voltage)0.25 … 8 A
Rated insulation voltage Ui75 V
Rated impulse withstand voltage Uimp1.5 kV
Operating voltage DC
UB24 V DC -15% … +15% regulated, residual ripple < 5%
Turn-on time
Safety outputsmax. 300 ms
EMC protection requirementsaccording to EN IEC 60947-5-3
Utilization category
DC-1324V 150mA 
Risk time according to EN 60947-5-3max. 260 ms
Safety classIII
Degree of contamination (external, according to EN 60947-1)3
Monitoring output OUT
Output typep-switching, short circuit-proof
Output voltage0.8 x UB … UB V DC
Switching currentmax. 50 mA
Safety outputs OA / OB
Output typeSemiconductor outputs, p-switching, short circuit-proof
rated conditional short-circuit current100 A
Discrepancy timemax. 10 ms
Output voltage
HIGH U(OA,OB)UB-1.5V … UB V DC 
LOW U(OA,OB)0 … 1 V DC
Switching current
per safety output1 … 150 mA
Off-state current Irmax. 0.25 mA
Test pulsesmax. 0.3 ms 
Test pulse intervalmin. 100 ms

Mechanical values and environment

ConnectionConnecting cable PUR, 0.2 m, with plug connector M12, 5-pin
Degree of protectionIP67
Ready delay0.5 s
Material
HousingPlastic, PBT
Dynamic bending radius10 x cable diameter
Static bending radius5 x cable diameter
Installation orientationany
Switching frequencymax. 1 Hz
Tightening torque
Fixing screwsmax. 1 Nm
Mounting distance
between 2 switches or 2 actuatorsmin. 400 mm
Mounting typeSurface mounting on metal
Shock and vibration resistanceaccording to EN IEC 60947-5-3
Cable ambient temperature (dynamic)-5 … +65 °C
Cable ambient temperature (static)-25 … +65 °C

Reliability values acc. to EN ISO 13849-1

Mission time20 y
Monitoring of the guard position
Category4
Performance LevelPL e
PFHD1.8 x 10-9

Miscellaneous

The following applies to the approval according to ULOperation only with UL Class 2 power supply or equivalent measures

In combination with actuator CES-A-BLN-R2-100776, CES-A-BLN-U2-103450, CES-A-BLN-L2-104510, CES-A-BLN-U2-112710

Assured operating distances saomin. 10 mm
Assured release distance sar
in x/z directionmax. 40 mm
in y directionmax. 60 mm
Operating distance15 mm
Switching hysteresis1 … 2 mm

In combination with actuator CES-A-BDN-06-104730

Assured operating distances saomin. 14 mm
Assured release distance sar
in y directionmax. 60 mm
in x/z directionmax. 40 mm
Operating distance19 mm
Switching hysteresis1 … 2 mm

Still not sure what you want?

We are here to help you, send us your details we will assist you to choose right product.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Know the part number Search here
EUCHNER CES-AP-CL2-CH-SB-106551

EUCHNER CES-AP-CL2-CH-SB-106551

Fill up the form and we will get back to you in few hours with right details. fill the form to help you better way.