ORDER NO. 111708
Order number | 111708 |
Item designation | CES-AP-C01-CH-SB-111708 |
Gross weight | 0,194kg |
Customs tariff number | 85365019 |
Non-contact safety switch CES-AP-C01-…
- Safety switch with integrated evaluation electronics
- No series connection
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Category 4 / PL e according to EN ISO 13849-1
- M12 plug connector 5-pin; pin 5 not used
- Multicode
Approach direction
Can be adjusted in 90° steps
Short circuit monitoring
The switch generates its own clock signal on the output lines OA/OB.
Pay attention to this aspect when connecting to control systems and relays.
Multicode evaluation
Every suitable actuator is detected by the switch.
Category according to EN 13849-1
Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
- Category 4/PL e according to EN 13849-1
Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated.
LED indicator
STATE | Status LED |
DIA | Diagnostics LED |
Additional connections
DIA | Diagnostics output (semiconductor) |
RST | Reset input |
Typical actuating ranges
With actuators CES-A-BBA and CES-A-BCA
For a side approach direction for the actuator and safety switch, a minimum distance of s = 4 mm must be maintained so that the actuating range of the side lobes is not entered.
With actuator CES-A-BPA
For a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm must be maintained so that the actuating range of the side lobes is not entered.
Connector assignment
Plug connector (view of connection side) | Pin | Designation | Function | Connecting cable conductor coloring |
---|---|---|---|---|
1 | UB | Power supply, DC 24 V | BN | |
2 | OA | Safety output, channel 1 | WH | |
3 | 0V | Ground, DC 0 V | BU | |
4 | OB | Safety output, channel 2 | BK | |
5 | – | n.c. | GY |