ORDER NO. 113272
Order number | 113272 |
Item designation | CET1-AR-CRA-CH-50F-SG-C2333-113272 |
Gross weight | 1,346kg |
Customs tariff number | 85365019 |
Non-contact safety switch CET-AR-…, M12, with escape release and lockout bar
- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 6,500 N
- Up to 20 switches in series
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Category 4 / PL e according to EN ISO 13849-1
- With 2 plug connectors M12
- Multicode
- Escape release, 75 mm long
- Lockout mechanism
- Multicode
- Approach direction A (delivery state)
Approach direction
Horizontal
Can be adjusted in 90° steps
Escape release
This is used for manual release of guard locking from the danger zone without tools.
Lockout mechanism
The lockout bar can be used to prevent maintenance personnel from being unintentionally locked in the danger zone, for example.
Important: The lockout bar is not a safety function.
This device with lockout bar possesses no auxiliary release.
Safety switch
The device may be operated only in conjunction with the actuator CET-A-….
Important: The actuator must be ordered separately.
Multicode evaluation unit
Every suitable actuator is detected by the switch.
Solenoid operating voltage
- DC 24 V +10%, -15%
Guard locking type
CET1 | Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid. |
LED function display
State LED | Status LED |
DIA LED | Diagnostics LED |
LED 1 rd | freely configurable |
LED 2 gn | freely configurable |
Additional connections
OUT | Monitoring output (semiconductor) |
RST | Reset input |
Category according to EN ISO 13849-1
Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
- Category 4 / PL e according to EN ISO 13849-1
- The stated safety characteristics apply to any installation orientations of the safety switch.
Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated.
Work area
Repeat accuracy R | |
according to EN 60947-5-2 | 10 % |
Electrical connection ratings
Power consumption | |
Solenoid | 11 W |
Current consumption | |
ICM | 450 mA |
IB | 80 mA |
Fusing | |
external (operating voltage UB) | 0.25 … 8 A |
external (operating voltage UCM) | 0.5 … 8 A |
Operating voltage DC | |
LED1, LED2 | 24 V DC -15% V DC … +10% V DC |
UB | 24 V DC -15% … +15% reverse polarity protected, regulated, residual ripple < 5%, PELV |
EMC protection requirements | according to EN IEC 60947-5-3 |
Utilization category | |
DC-13 | 24V 200mA |
Solenoid operating voltage DC | |
UCM | 24 V DC -15% … +10% reverse polarity protected, regulated, residual ripple < 5%, PELV |
Solenoid duty cycle | 100 % |
Switching load | |
according to UL | 24V DC, Class 2 |
Safety class | |
EN IEC 61140 | III |
Test pulses | max. 1 ms |
Degree of contamination (external, according to EN 60947-1) | 3 |
Monitoring output OUT | |
Output type | Semiconductor output, p-switching, short circuit-proof |
Output current | |
OUT | 1 … 50 mA |
Output voltage | |
OUT | 0.8xUB … UB V DC |
Safety outputs OA / OB | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
Output current | |
per safety output | 1 … 200 mA |
Discrepancy time | |
both safety outputs | max. 10 ms |
Output voltage | |
HIGH U(OA,OB) | UB-1.5V … UB V DC |
LOW U(OA,OB) | 0 … 1 V DC |
Turn-on time | |
Safety outputs | 400 ms |
Off-state current Ir | max. 0.25 mA |
Risk time according to EN 60947-5-3 | |
Single device | max. 400 ms |
Risk time according to EN 60947-5-3, extension for each additional device | max. 5 ms |
Mechanical values and environment
Approach speed | max. 20 m/min |
Connection | 2 plug connectors M12, 5- and 8-pin |
Degree of protection | IP67 |
Ready delay | 10 s |
Material | |
Ramp | stainless steel |
Safety switch housing | Die-cast aluminum |
Mechanical life | 2 x 10⁶ |
Installation orientation | any |
Switching frequency | max. 0.5 Hz |
Degree of freedom X | ±5 mm |
Degree of freedom Y | ±5 mm |
Degree of freedom Z | ±4 mm |
Shock and vibration resistance | according to EN IEC 60947-5-3 |
Ambient temperature | |
at UB = 24V DC | -20 … +55 °C |
Locking force Fmax | 6500 N |
Locking force FZh | 5000 N |
Guard locking principle | Closed-circuit current principle |
Reliability values acc. to EN ISO 13849-1
Mission time | 20 y |
Control of guard locking | |
Category | Depending on external control of guard locking |
Performance Level | Depending on external control of guard locking |
PFHD | Depending on external control of guard locking |
Monitoring of guard locking and the guard position | |
Category | |
Any installation orientation | 4 |
Performance Level | PL e |
PFHD | |
Any installation orientation | 3.1 x 10-9 |
Miscellaneous
C number | |
C2333 | with mounted lockout mechanism |
The following applies to the approval according to UL | Operation only with UL Class 2 power supply or equivalent measures; see operating instructions |