IFM IFM SA5000

ifm distributor in India

IFM SA5000

IFM

We are IFM Product supplier in India

Flow sensor

  • Measurement of flow and temperature at the same time
  • Optimised for water, oils and air
  • Red/green display for clear identification of the acceptable range
  • With switching output, analogue signal and IO-Link
  • The process connection can be rotated for optimum alignment
Product characteristics
Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Process connectionthreaded connection M18 x 1,5 internal thread
Application
Special featureGold-plated contacts
Mediawater; glycol solutions; air; oils
Note on medialow-viscosity oils with viscosity: ≤ 40 mm²/s (40 °C)high-viscosity oils with viscosity: > 40 mm²/s (40 °C)
Medium temperature [°C]-20…90
Pressure rating [bar]100
Pressure rating [Mpa]10
MAWP (for applications according to CRN) [bar]100
Electrical data
Operating voltage [V]18…30 DC
Current consumption [mA]< 100
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]10
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs2
Output signalswitching signal; analogue signal; frequency signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]2.5
Permanent current rating of switching output DC [mA]250
Number of analogue outputs1
Analogue current output [mA]4…20; (scalable)
Max. load [Ω]350
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Frequency of the output [Hz]0…1000
Measuring/setting range
Probe length L [mm]45
Operating moderelative; absolutely liquid; absolutely gaseous; (absolute: reference measurement recommended)
Note on factory settingOperating mode: relative
Temperature monitoring
Measuring range [°C]-20…90
Resolution [°C]0.2
Liquid media – absolute operating mode
Setting range [m/s]0.04…3
Greatest sensitivity [m/s]0.04…3
Liquid media – relative operating mode
Setting range [m/s]0.04…6
Greatest sensitivity [m/s]0.04…3
Gases – operating mode “absolute”
Setting range [m/s]0…100
Greatest sensitivity [m/s]30…100
Gases – operating mode “relative”
Setting range [m/s]0…200
Greatest sensitivity [m/s]30…100
Accuracy / deviations
Temperature drift [cm/s x 1/K]0,003 m/s x 1/K (< 20 °C; > 70 °C)
Temperature gradient [K/min]100
Absolute operating mode
Repeatability0,05 m/s; (water; flow velocity: 0,05…3 m/s)
Relative operating mode
Accuracy± (7 % MW + 2 % MEW); (for relative mode in the range of maximum sensitivity under the following conditions:; water: 20…70 °C; inlet length: 1.5 m; DN25 (DIN 2448); mounting position according to instructions; Accuracy can differ for other media and mounting positions.)
Repeatability0,05 m/s; (water; flow velocity: 0,05…3 m/s)
Temperature monitoring
Temperature drift± 0,005 K/°C
Accuracy [K]± 0,3 / ± 1; (water; flow velocity: 0,3…3 m/s / air; flow velocity: > 10 m/s)
Response times
Response time [s]0.5; (T09; water; glycol: 0,8 s; air: 7 s; oil: 1,8 s; each T09)
Temperature monitoring
Dynamic response T05 / T09 [s]1,5 (T09); (water; flow velocity: 0,3…3 m/s)
Software / programming
Parameter setting optionshysteresis / window; normally open / normally closed; switching logic; current/frequency output; medium selection; Damping; Teach function; display can be rotated and switched off; standard unit of measurement; process value colour
Interfaces
Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
ProfilesSmart Sensor: Process Data Variable; Device Identification, Device Diagnosis
SIO modeyes
Required master port typeA
Process data analogue2
Process data binary2
Min. process cycle time [ms]3
Supported DeviceIDsType of operationDeviceIDFactory setting / ModE = (REL)533ModE = (LIQU)540ModE = (GAS)547
Operating conditions
Ambient temperature [°C]-40…80
Storage temperature [°C]-40…100
ProtectionIP 65; IP 67
Tests / approvals
EMCDIN EN 60947-5-9
Shock resistanceDIN EN 60068-2-2750 g (11 ms)
Vibration resistanceDIN EN 60068-2-620 g (10…2000 Hz)
MTTF [years]132
UL approvalUL Approval no.I003
Mechanical data
Weight [g]314
Materialsstainless steel (1.4404 / 316L); stainless steel (1.4310 / 301); PBT-GF20; PBT-GF30
Materials (wetted parts)stainless steel (1.4404 / 316L); Gasket: FKM
Process connectionthreaded connection M18 x 1,5 internal thread
Displays / operating elements
DisplayDisplay unit6 x LED, green (%, m/s, l/min, m³/h, °C, 10³)switching status2 x LED, yellowmeasured valuesalphanumeric display, red/green 4-digit
Remarks
RemarksMW = measured valueMEW = Final value of the measuring range
Pack quantity1 pcs.
Electrical connection
ConnectionConnector: 1 x M12; coding: A; Contacts: gold-plated
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — SA5000-01 — 26.04.2021 

IFM SA5000

Fill up the form and we will get back to you in few hours with right details. fill the form to help you better way.