Part Code – 11128096
Insulated blind hollow shaft ø12…16 mm, cone shaft ø17 mm
- Robust, compact housing
- Two bearings with large distance, one at each end
- High shaft load up to 450 N
- Shaft insulation up to 2.8 kV
- Highest operating speed 10000 rpm
- Terminal box, turn by 180°
Technical data – electrical ratings
Voltage supply
- 9…30 VDC
- 5 VDC ±5 %
Consumption w/o load
- ≤100 mA
Pulses per revolution
- 500 … 5000
Phase shift
- 90 ° ±20°
Duty cycle
- 45…55 %
- 40…60 % (>3072 pulses)
Reference signal
- Zero pulse, width 90°
Sensing method
- Optical
Output frequency
- ≤120 kHz
- ≤300 kHz (on request)
Output signals
- K1, K2, K0 + inverted
- Error output (option EMS)
Output stages
- HTL-P (power linedriver)
- TTL/RS422
Shaft insulation
- Suitable up to 2.8 kV
Transmission length
- ≤350 m at 100 kHz (HTL-P)
- ≤550 m at 100 kHz (TTL)
Interference immunity
- EN 61000-6-2
Emitted interference
- EN 61000-6-3
Approval
- CE
- UL approval / E217823
Technical data – mechanical design
Size (flange)
- ø99 mm
Shaft type
- ø12…16 mm (blind hollow shaft)
- ø17 mm (cone shaft 1:10)
Admitted shaft load
- ≤350 N axial
- ≤450 N radial
Motor shaft tolerance
- 0.2 mm radial
Protection EN 60529
- IP 66
Operating speed
- ≤10000 rpm (mechanical)
Operating torque
- ≤6 Ncm
Rotor moment of inertia
- 160 gcm²
Material
- Housing: aluminium, coated
- Shaft: stainless steel
Operating temperature
- -40…+100 °C
- -40…+90 °C (fixed cable)
- -25…+100 °C (>3072 pulses)
Resistance
- IEC 60068-2-6
- Vibration 20 g, 10-2000 Hz
- IEC 60068-2-27
- Shock 250 g, 6 ms
Corrosion protection
- IEC 60068-2-52 Salt mist
- for ambient conditions C4 according to ISO 12944-2
Explosion protection
- II 3 G Ex ec IIC T4 Gc (gas)
- II 3 D Ex tc IIIC T135°C Dc (dust)
- (only with option ATEX)
Connection
- Terminal box
- Flange connector M23, 12-pin
- Cable 1 m
Weight approx.
- 1.3 kg