ORDER NO. 082201
Precision single hole fixing limit switch EGT12
- with reed contact and protective diode
- Plunger material stainless steel
- Any installation orientation
Switching element
Reed contact, 1 NO contact
Do not switch incandescent lamps under any circumstances. Not even for testing purposes. Do not use built-in limit switches as a stop.
Electrical connection values
| Connection cross section | 0.5 mm² |
| Rated insulation voltage Ui | 50 V |
| Utilization category | |
| AC-12 | 0.3A 30V |
| DC-13 | 0.3A 24V |
| Short circuit protection according to IEC 60269-1 | 0.4A gG |
| Switching voltage | |
| min. | 1 V |
| Switching current | |
| min. at 24 V | 1 mA |
Mechanical values and environment
| Approach speed | 0.01 … 8 m/min |
| Connection type | PUR cable |
| Number of NO contacts | 1 |
| Design | Thread M12 x 1 |
| Actuating element | Rounded plunger |
| Actuating force | |
| approx. | 16 N |
| Installation orientation | any |
| Cable length | 5 m |
| Mechanical life | 30 x 10⁶ |
| Switching principle | Reed contact |
| Degree of protection | IP68 |
| Cable ambient temperature (static) | -25 … +80 °C |
| Material | |
| Contact | Rhodium |
| Sleeve | Plastic |
| Threaded section | stainless steel |
| Repeat accuracy (absolute) | ±0.01 mm |