Article no.: 11231082
Baumer Performance sensor
- Automatic adjustment of exposure time for precise measurements on changing materials
- High immunity to ambient light for reliable measurements regardless of ambient conditions
- Point beam shape for a precise measurement
- Adjustable filters for particularly stable measurement results
General data
Type
- Distance measuring
Measuring distance Sd
- 50 … 550 mm
Measuring range Mr
- 500 mm
Adjustment
- Teach-in: button / IO-Link
Power on indication
- LED green
Output indicator
- LED yellow
Repeat accuracy
- 2 … 86 µm
Linearity error
- ± 0.23 % Mr
Beam type
- Point
Temperature drift
- 0,08 % Sde/K
Light Source
Light source
- Pulsed red laser diode
Wave length
- 660 nm
Laser class
- 2
Maximum pulse power
- 2 mW
Pulse duration
- 0.001 … 1.2 ms
Pulse period
- 0.2 … 3.4 ms
Electrical data
Response delay
- 0.4 ms
Measuring frequency
- 5000 Hz
Voltage supply range +Vs
- 12 … 28 VDC
Current consumption max. (no load)
- 50 mA
Output circuit
- Analog and digital
Output signal
- 4 … 20 mA / 2 … 10 mA
Load resistance
- < (+Vs – 9 V) / 0.02 A
Output current
- < 100 mA
Short circuit protection
- Yes
Reverse polarity protection
- Yes, Vs to GND
Communication interface
Interface
- IO-Link V1.1
IO-Link port type
- Class A
Baud rate
- 230,4 kBaud (COM 3)
Cycle time
- ≥ 1 ms
Process data length
- 48 Bit
Process data structure
- Smart Sensor Profile – DMS PDI48.INT32_INT8
- Bit 0 = SSC1 (distance)
- Bit 2 = quality
- Bit 3 = alarm
- Bit 8-15 = scale factor
- Bit 16-47 = 32 Bit measurement
Mechanical data
Width / diameter
- 13.6 mm
Height / length
- 49 mm
Depth
- 40.3 mm
Type
- Rectangular, front view
Housing material
- Die-cast zinc
Front (optics)
- Glass
Connection types
- Connector M8 4 pin
Weight
- 67 g
Ambient conditions
Ambient light immunity
- < 100 kLux
Protection class
- IP 67
Operating temperature
- -10 … +50 °C
Storage temperature
- -20 … +60 °C
Vibration (sinusoidal)
- IEC 60068-2-6:2008
- 1 mm p-p at f = 10 – 55 Hz, duration 5 min per axis
- 30 min endurance at f = 55 Hz per axis
Shock (semi-sinusoidal)
- IEC 60068-2-27:2009
- 30 g / 11 ms, 6 jolts per axis and direction