Baumer TDP 0,2 LT-4 – Flange Mounting

TDP 0,2 LT-4 – Flange Mounting

Baumer

We are Baumer authorized distributor in india

Part Code – 11070721

Solid shaft with EURO flange B10 or housing foot B3

  • Low response time
  • Open circuit voltage 10…150 mV per rpm
  • Redundant output (TDPZ)
  • EURO flange B10 or housing foot B3
  • Very high resistance to shock
  • High signal quality due to patented LongLife technology
  • Recognition of sense of rotation possible via control

Technical data – electrical ratings

Reversal tolerance

  • ≤0.1 %

Linearity tolerance

  • ≤0.15 %

Temperature coefficient

  • ± 0.05 %/K (open-circuit)

Isolation class

  • B

Calibration tolerance

  • ±1 %

Climatic test

  • Humid heat, constant (IEC 60068-2-3, Ca)

Performance

  • TDP: 12 W (speed ≥3000 rpm)
  • TDPZ: 2x 3 W (speed ≥3000 rpm)

Armature-circuit time-constant

  • <75 µs (TDP)
  • <40 µs (TDPZ)

Open-circuit voltage

  • TDP: 10…150 mV per rpm
  • TDPZ: 20…100 mV per rpm

Interference immunity

  • EN 61000-6-2

Emitted interference

  • EN 61000-6-3

Approval

  • CE
  • CSA

Technical data – mechanical design

Size (flange)

  • ø115 mm

Shaft type

  • ø11 mm solid shaft
  • ø7 mm solid shaft (optional)
  • ø14 mm solid shaft (optional)

Flange

  • EURO flange B10
  • Housing foot B3

Protection EN 60529

  • IP 55
  • IP 56 (option)

Operating speed

  • ≤10000 rpm

Torque

  • 1.5 Ncm

Rotor moment of inertia

  • 1.1 kgcm² (TDP)
  • 1.2 kgcm² (TDPZ)

Admitted shaft load

  • ≤60 N axial
  • ≤80 N radial

Material

  • Housing: aluminium die-cast
  • Shaft: stainless steel

Operating temperature

  • -30…+130 °C

Resistance

  • IEC 60068-2-6
  • Vibration 10 g, 10-2000 Hz
  • IEC 60068-2-27
  • Shock 300 g, 1 ms

Weight approx.

  • 2.4 kg (TDP)
  • 2.9 kg (TDPZ)

Connection

  • Terminal box