We are EUCHNER CES-A-ABA-01B product supplier in India
ORDER NO. 083513
Order number
083513
Item designation
CES-A-ABA-01B
Gross weight
0,247kg
European Article Number (EAN)
4047048000810
Customs tariff number
85364110
Evaluation unit CES-A-ABA…/CES-A-UBA… (for 1 read head)
1 read head can be connected
2 safety contacts (relay contacts)
1 internal normally open contact per safety contact
Unicode evaluation unit
Category 3 / PL e according to EN ISO 13849-1
Unicode evaluation unit
Each actuator is highly coded (unicode). The evaluation unit detects only actuators that have been taught-in. Max. 8 actuators can be taught-in.
Only the last actuator taught-in is detected.
Category according to EN ISO 13849-1
Due to two redundant relay outputs (safety outputs) with internally monitored contacts, suitable for:
Category 3 / PL e according to EN ISO 13849-1
To achieve the stated category, both safety contacts must always be evaluated.
Actuating range
The standard version of the evaluation unit (CES-A-…-01B) has a large actuating range that, e.g., permits larger tolerances in the alignment of read head and actuator. Wherever a smaller actuating range is required, the version with reduced actuating range (CES-A-…-01) can be used.
TST
Input for self-test
OUT
Monitoring output (semiconductor)
ERR
Diagnostic output
GND
Connected internally to 0V (not for high currents)
Work area
Repeat accuracy R
according to EN 60947-5-2
max. 10 %
Controls and indicators
LED indicator
Safety output status
Status LED
Diagnostics LED
Electrical connection ratings
Connection cross-section
(screw terminals)
0.25 … 2.5 mm²
Current consumption
(with relay energized)
150 mA
Fusing
external (operating voltage UB)
0.25 … 8 A
Operating voltage DC
UB
21 … 24 … 27 V DC regulated, residual ripple < 5%
EMC protection requirements
according to EN 60947-5-3
Degree of contamination (external, according to EN 60947-1)
2
Input: test input TST
Input voltage
HIGH
15 … UB V DC
LOW
0 … 2 V DC
Monitoring outputs: diagnostics ERR, door monitoring output OUT
Output type
Semiconductor output, p-switching, not short circuit-proof
Output current
max. 20 mA
Output voltage
0.8 x UB … UB V DC
Safety contacts 13/14, 23/24
Output type
Relay contacts, floating
Fusing
external (safety circuit) according to EN 60269-1
6 AgG or 6 A circuit breaker (characteristic B or C)
rated conditional short-circuit current
100 A
Rated insulation voltage Ui
63 V
Rated impulse withstand voltage Uimp
1.5 kV
Discrepancy time
(between the operating points of both relays)
max. 120 ms
Switching current
at switching voltage AC/DC 21 … 60 V
1 … 300 mA
at switching voltage AC/DC 10 … 30 V
10 … 6000 mA
Utilization category
DC-12
30 V 6 A
DC-12
60 V 0.3 A
AC-12
60 V 0.3 A
DC-14
30 V 2 A
DC-13
24 V 3 A
AC-12
30 V 6 A
Switching load
according to c UL us
Class 2 max. 30 V AC / Class 2 max. 60 V DC; 120 V AC 3 A / 240 V AC 1.5 A
Mechanical values and environment
Number of read heads
1 read head can be connected
Connection
plug-in screw terminals, coded
Degree of protection
IP20
Ready delay
max. 3 s
Material
Housing
Plastic PA6.6
Switching frequency
max. 1 Hz
Reaction time
after change in the actuation status
max. 180 ms
Atmospheric humidity
not condensing
max. 80 % rH
Mounting distance
laterally to the neighboring device
min. 10 mm
Mounting type
Mounting rail 35 mm according to DIN EN 60715 TH35
Ambient temperature
at UB = 24V DC
-20 … +55 °C
Dwell time
min. 0.5 s
Safety contacts 13/14, 23/24
Number of safety contacts
2 Relay with internally monitored contacts
Mechanical life
Operating cycles (relay)
10 x 10⁶
Reliability values acc. to EN ISO 13849-1
Diagnostic Coverage (DC)
90 %
Number of switching cycles
≤ 0.1 A at 24 V DC
max. 760000 1/y
≤ 1 A at 24 V DC
max. 153000 1/y
≤ 3 A at 24 V DC
max. 34600 1/y
Mission time
20 y
Monitoring of the guard position
Category
3
Performance Level
PL e
PFHD
4.3 x 10-8
Miscellaneous
The following applies to the approval according to UL
Operation only with UL Class 2 power supply or equivalent measure.
In combination with read head CES-A-LQA-SC and actuator CES-A-BBA-071840, CES-A-BCA
Assured operating distances sao
for vertical approach direction (center offset m=0)
min. 10 mm
for side approach direction (distance in x direction 8 mm)
min. +/- 18 mm
Assured release distance sar
max. 47 mm
Operating distance
for side approach direction (distance in x direction 8 mm)
+/- 22 mm
for vertical approach direction (center offset m=0)
15 mm
Switching hysteresis
for vertical approach direction
2 … 3 mm
for side approach direction (distance in x direction 8 mm)
1 … 1.8 mm
In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V
Mounting distance
neighboring read heads
min. 50 mm
In combination with read head CES-A-LQA-SC
Mounting distance
neighboring read heads
min. 80 mm
In combination with read head CES-A-LMN-SC
Mounting distance
neighboring read heads
min. 20 mm
In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V and actuator CES-A-BDA-20
Actuator distance s
Minimum distance for side approach direction
min. 4 mm
Assured operating distances sao
with center offset m=0
min. 11 mm
Assured release distance sar
max. 33 mm
Operating distance
with center offset m=0
16 mm
Switching hysteresis
0.5 … 2 mm
In combination with read head CES-A-LQA-SC and actuator CES-A-BQA
Assured operating distances sao
for vertical approach direction (center offset m=0)
min. 16 mm
for side approach direction (distance in x direction 10 mm)
min. +/- 24 mm
Assured release distance sar
max. 60 mm
Operating distance
for side approach direction (distance in x direction 10 mm)
+/- 28 mm
for vertical approach direction (center offset m=0)
23 mm
Switching hysteresis
for vertical approach direction
2 … 3 mm
for side approach direction (distance in x direction 10 mm)
1 … 1.3 mm
In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V and actuator CES-A-BBA-071840, CES-A-BCA
Actuator distance s
Minimum distance for side approach direction
min. 3 mm
Assured operating distances sao
with center offset m=0
min. 10 mm
Assured release distance sar
max. 32 mm
Operating distance
with center offset m=0
15 mm
Switching hysteresis
0.5 … 2 mm
In combination with read head CES-A-LMN-SC and actuator CES-A-BMB
Actuator distance s
Minimum distance
min. 1.2 mm
Assured operating distances sao
with center offset m=0
min. 3.5 mm
Assured release distance sar
max. 10 mm
Operating distance
with center offset m=0
5 mm
Switching hysteresis
0.1 … 0.3 mm
Still not sure what you want?
We are here to help you, send us your details we will assist you to choose right product.
Know the part number Search here
EUCHNER CES-A-ABA-01B
Fill up the form and we will get back to you in few hours with right details. fill the form to help you better way.