We are EUCHNER CES-A-ABA-01B product supplier in India
ORDER NO. 083513
Order number
083513
Item designation
CES-A-ABA-01B
Gross weight
0,247kg
European Article Number (EAN)
4047048000810
Customs tariff number
85364110
Evaluation unit CES-A-ABA…/CES-A-UBA… (for 1 read head)
1 read head can be connected
2 safety contacts (relay contacts)
1 internal normally open contact per safety contact
Unicode evaluation unit
Category 3 / PL e according to EN ISO 13849-1
Unicode evaluation unit
Each actuator is highly coded (unicode). The evaluation unit detects only actuators that have been taught-in. Max. 8 actuators can be taught-in.
Only the last actuator taught-in is detected.
Category according to EN ISO 13849-1
Due to two redundant relay outputs (safety outputs) with internally monitored contacts, suitable for:
Category 3 / PL e according to EN ISO 13849-1
To achieve the stated category, both safety contacts must always be evaluated.
Actuating range
The standard version of the evaluation unit (CES-A-…-01B) has a large actuating range that, e.g., permits larger tolerances in the alignment of read head and actuator. Wherever a smaller actuating range is required, the version with reduced actuating range (CES-A-…-01) can be used.
TST
Input for self-test
OUT
Monitoring output (semiconductor)
ERR
Diagnostic output
GND
Connected internally to 0V (not for high currents)
Work area
Repeat accuracy R
according to EN 60947-5-2
max. 10 %
Controls and indicators
LED indicator
Safety output status
Status LED
Diagnostics LED
Electrical connection ratings
Connection cross-section
(screw terminals)
0.25 … 2.5 mm²
Current consumption
(with relay energized)
150 mA
Fusing
external (operating voltage UB)
0.25 … 8 A
Operating voltage DC
UB
21 … 24 … 27 V DC regulated, residual ripple < 5%
EMC protection requirements
according to EN 60947-5-3
Degree of contamination (external, according to EN 60947-1)
2
Input: test input TST
Input voltage
HIGH
15 … UB V DC
LOW
0 … 2 V DC
Monitoring outputs: diagnostics ERR, door monitoring output OUT
Output type
Semiconductor output, p-switching, not short circuit-proof
Output current
max. 20 mA
Output voltage
0.8 x UB … UB V DC
Safety contacts 13/14, 23/24
Output type
Relay contacts, floating
Fusing
external (safety circuit) according to EN 60269-1
6 AgG or 6 A circuit breaker (characteristic B or C)
rated conditional short-circuit current
100 A
Rated insulation voltage Ui
63 V
Rated impulse withstand voltage Uimp
1.5 kV
Discrepancy time
(between the operating points of both relays)
max. 120 ms
Switching current
at switching voltage AC/DC 21 … 60 V
1 … 300 mA
at switching voltage AC/DC 10 … 30 V
10 … 6000 mA
Utilization category
DC-12
30 V 6 A
DC-12
60 V 0.3 A
AC-12
60 V 0.3 A
DC-14
30 V 2 A
DC-13
24 V 3 A
AC-12
30 V 6 A
Switching load
according to c UL us
Class 2 max. 30 V AC / Class 2 max. 60 V DC; 120 V AC 3 A / 240 V AC 1.5 A
Mechanical values and environment
Number of read heads
1 read head can be connected
Connection
plug-in screw terminals, coded
Degree of protection
IP20
Ready delay
max. 3 s
Material
Housing
Plastic PA6.6
Switching frequency
max. 1 Hz
Reaction time
after change in the actuation status
max. 180 ms
Atmospheric humidity
not condensing
max. 80 % rH
Mounting distance
laterally to the neighboring device
min. 10 mm
Mounting type
Mounting rail 35 mm according to DIN EN 60715 TH35
Ambient temperature
at UB = 24V DC
-20 … +55 °C
Dwell time
min. 0.5 s
Safety contacts 13/14, 23/24
Number of safety contacts
2 Relay with internally monitored contacts
Mechanical life
Operating cycles (relay)
10 x 10⁶
Reliability values acc. to EN ISO 13849-1
Diagnostic Coverage (DC)
90 %
Number of switching cycles
≤ 0.1 A at 24 V DC
max. 760000 1/y
≤ 1 A at 24 V DC
max. 153000 1/y
≤ 3 A at 24 V DC
max. 34600 1/y
Mission time
20 y
Monitoring of the guard position
Category
3
Performance Level
PL e
PFHD
4.3 x 10-8
Miscellaneous
The following applies to the approval according to UL
Operation only with UL Class 2 power supply or equivalent measure.
In combination with read head CES-A-LQA-SC and actuator CES-A-BBA-071840, CES-A-BCA
Assured operating distances sao
for vertical approach direction (center offset m=0)
min. 10 mm
for side approach direction (distance in x direction 8 mm)
min. +/- 18 mm
Assured release distance sar
max. 47 mm
Operating distance
for side approach direction (distance in x direction 8 mm)
+/- 22 mm
for vertical approach direction (center offset m=0)
15 mm
Switching hysteresis
for vertical approach direction
2 … 3 mm
for side approach direction (distance in x direction 8 mm)
1 … 1.8 mm
In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V
Mounting distance
neighboring read heads
min. 50 mm
In combination with read head CES-A-LQA-SC
Mounting distance
neighboring read heads
min. 80 mm
In combination with read head CES-A-LMN-SC
Mounting distance
neighboring read heads
min. 20 mm
In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V and actuator CES-A-BDA-20
Actuator distance s
Minimum distance for side approach direction
min. 4 mm
Assured operating distances sao
with center offset m=0
min. 11 mm
Assured release distance sar
max. 33 mm
Operating distance
with center offset m=0
16 mm
Switching hysteresis
0.5 … 2 mm
In combination with read head CES-A-LQA-SC and actuator CES-A-BQA
Assured operating distances sao
for vertical approach direction (center offset m=0)
min. 16 mm
for side approach direction (distance in x direction 10 mm)
min. +/- 24 mm
Assured release distance sar
max. 60 mm
Operating distance
for side approach direction (distance in x direction 10 mm)
+/- 28 mm
for vertical approach direction (center offset m=0)
23 mm
Switching hysteresis
for vertical approach direction
2 … 3 mm
for side approach direction (distance in x direction 10 mm)
1 … 1.3 mm
In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V and actuator CES-A-BBA-071840, CES-A-BCA
Actuator distance s
Minimum distance for side approach direction
min. 3 mm
Assured operating distances sao
with center offset m=0
min. 10 mm
Assured release distance sar
max. 32 mm
Operating distance
with center offset m=0
15 mm
Switching hysteresis
0.5 … 2 mm
In combination with read head CES-A-LMN-SC and actuator CES-A-BMB
Actuator distance s
Minimum distance
min. 1.2 mm
Assured operating distances sao
with center offset m=0
min. 3.5 mm
Assured release distance sar
max. 10 mm
Operating distance
with center offset m=0
5 mm
Switching hysteresis
0.1 … 0.3 mm
EUCHNER CES-A-ABA-01B