ORDER NO. 097945
Order number | 097945 |
Item designation | CES-A-C5H-01-EX |
Gross weight | 0,545kg |
European Article Number (EAN) | 4047048006355 |
Customs tariff number | 85365019 |
Non-contact safety switch CES-A-C5… ATEX
- ATEX version
- With protective plate
- Suitable for use in zones 2 and 22 (gases and dusts)
- Safety switches as interlocking device of type 4
- Safety switch with integrated evaluation electronics
- Pulsed signals can be switched
- 2 safety outputs (semiconductor outputs)
- Up to category 4 / PL e according to EN ISO 13849-1
Approach direction
Can be adjusted in 90° steps
Protective plate
A protective plate included protects the safety switch against impacts on the housing and the ingress of an explosive atmosphere.
Unicode evaluation
Each actuator is highly coded (unicode). The evaluation unit detects only actuators that have been taught-in. Additional actuators can be taught-in.
Category according to EN ISO 13849-1
Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
- CES-A-C5H-01, category 4 / PL e according to EN ISO 13849-1
LED indicator
STATE | Status LED |
OUT/ERROR | Safety outputs status / diagnostics LED (combined) |
Additional connections
OUT | Monitoring output (semiconductor) |
Attention:
The actuating range may vary depending on the substrate material and installation situation.
Typical actuating range
(only in combination with actuators CES-A-BBA, CES-A-BCA)
For a side approach direction for the actuator and safety switch, a minimum distance of s = 4 mm must be maintained so that the actuating range of the side lobes is not entered. Typical actuating range
(only in combination with actuator CES-A-BPA)For a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm must be maintained so that the actuating range of the side lobes is not entered.
Work area
Repeat accuracy R | |
according to EN 60947-5-2 | max. 10 % |
Controls and indicators
LED indicator | |
Safety outputs status / diagnostics LED (combined) | |
Status LED |
Electrical connection ratings
Current consumption | 80 mA |
Fusing | |
(external) operating voltage | 0.25 … 8 A |
Rated insulation voltage Ui | 300 V |
Rated impulse withstand voltage Uimp | 1.5 kV |
Operating voltage DC | 21 … 24 … 27 V DC regulated, residual ripple < 5% |
EMC protection requirements | according to EN 60947-5-3 |
Degree of contamination (external, according to EN 60947-1) | 3 |
Monitoring output OUT | |
Output type | Semiconductor output, p-switching, short circuit-proof |
Output current | max. 20 mA |
Output voltage | 0.8 x UB … UB V DC |
Safety outputs LA / LB | |
Output type | Semiconductor outputs, p-switching, short circuit-proof, electrically decoupled |
Fusing | |
external, safety circuit U(+LA) / U(+LB) | 0.1 A medium slow-blow |
Output current | |
per safety output | 1 … 100 mA |
rated conditional short-circuit current | max. 100 A |
Discrepancy time | |
(between the operating points of both safety outputs) | max. 120 ms |
Output voltage | |
HIGH U(LB) | U(+LB) – 1.5 … U(+LB) V DC |
HIGH U(LA) | U(+LA) – 1.5 … U(+LA) V DC |
LOW U(LA) / U(LB) | 0 … 1 V DC |
Switching load | |
according to UL | max. DC 24 V, Class 2 |
Power supply output load | |
U(+LA) / U(+LB) | 18 … 24 … 27 V DC |
Mechanical values and environment
Dimensions | according to EN 60947-5-2 |
Connection | M12 plug connector, 8-pin; shield can be connected |
Degree of protection | IP65/IP67 |
Ready delay | max. 3 s |
Material | |
Housing | Plastic PBT V0 GF30 |
Installation orientation | any |
Switching frequency | max. 1 Hz |
Reaction time | |
after change in the actuation status | max. 180 ms |
Tightening torque | |
Fixing screws, housing | max. 1 Nm |
Screws, read head mounting bracket | max. 0.6 Nm |
Mounting distance | |
between 2 read heads or 2 actuators | min. 80 mm |
Ambient temperature | |
at UB = 24 V DC | -20 … +50 °C |
Dwell time | min. 0.5 s |
Reliability values acc. to EN ISO 13849-1
Diagnostic Coverage (DC) | 99 % |
Mission time | 20 y |
Monitoring of the guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 3.7 x 10-9 |
Miscellaneous
Explosion protection | |
incl. cover hood | II3G Ex ic ec IIB T5 Gc X / II3D Ex ic tc IIIC T90°C Dc X |
The following applies to the approval according to UL | Operation only with UL Class 2 power supply or equivalent measures |
In combination with actuator CES-A-BBA-EX-098158
Actuator distance s | |
Minimum distance for side approach direction | min. 4 mm |
Assured operating distances sao | |
with center offset m=0 | min. 18 mm |
Assured release distance sar | max. 40 mm |
Operating distance | |
with center offset m=0 | 20 mm |
Switching hysteresis | 2 … 3 mm |
In combination with actuator CES-A-BPA-EX-102125
Actuator distance s | |
Minimum distance for side approach direction | min. 6 mm |
Assured operating distances sao | |
with center offset m=0 | min. 15 mm |
Assured release distance sar | max. 58 mm |
Operating distance | |
with center offset m=0 | 22 mm |
Switching hysteresis | 1 … 2 mm |