Non-contact safety switch CES-AP-C01-…

  • Safety switch with integrated evaluation electronics
  • No series connection
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Category 4 / PL e according to EN ISO 13849-1
  • M12 plug connector 5-pin; pin 5 not used
  • Multicode

Approach direction

Can be adjusted in 90° steps

Short circuit monitoring

The switch generates its own clock signal on the output lines OA/OB.

Pay attention to this aspect when connecting to control systems and relays.

Multicode evaluation

Every suitable actuator is detected by the switch.

Category according to EN 13849-1

Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:

  • Category 4/PL e according to EN 13849-1

Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated.

LED indicator

STATEStatus LED
DIADiagnostics LED

Additional connections

DIADiagnostics output (semiconductor)
RSTReset input

Typical actuating ranges

With actuators CES-A-BBA and CES-A-BCA

<p>With actuators CES-A-BBA and CES-A-BCA</p>

For a side approach direction for the actuator and safety switch, a minimum distance of s = 4 mm must be maintained so that the actuating range of the side lobes is not entered.

With actuator CES-A-BPA

<p>With actuator CES-A-BPA</p>

For a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm must be maintained so that the actuating range of the side lobes is not entered.

Connector assignment

Plug connector (view of connection side)PinDesignationFunctionConnecting cable conductor coloring
1UBPower supply, DC 24 VBN
2OASafety output, channel 1WH
30VGround, DC 0 VBU
4OBSafety output, channel 2BK
5n.c.GY
Still not sure what you want?

We are here to help you, send us your details we will assist you to choose right product.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Know the part number Search here
EUCHNER CES-AP-C01-AH-SB-111145

EUCHNER CES-AP-C01-CH-SB-111708

Fill up the form and we will get back to you in few hours with right details. fill the form to help you better way.