ORDER NO. 106552

Order number106552
Item designationCES-AP-CR2-AH-SB-106552
Gross weight0,099kg
Customs tariff number85365019

Non-contact safety switch CES-AP-CR2-… , M12, PUR

  • Safety switch with integrated evaluation electronics
  • No series connection
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Door hinge right
  • Category 4 / PL e according to EN ISO 13849-1
  • Connecting cable PUR, 0.2 m, plug connector M12, 5-core
  • Unicode
  • Two safety screws M4x14 included

Short circuit monitoring

The switch generates its own clock signal on the output lines OA/OB.

Pay attention to this aspect when connecting to control systems and relays.

Unicode evaluation

Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can be taught-in. Only the last actuator taught-in is detected.

Category according to EN 13849-1

Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:

  • Category 4/PL e according to EN 13849-1

Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated.

LED indicator

STATEStatus LED
DIADiagnostics LED

Additional connection

OUTMonitoring output (semiconductor)

Approach directions

<p>Approach directions</p>

Typical actuating range

(Actuator CES-A-BLN… in conjunction with safety switch CES-AP-C.2-… in case of mounting on plastic)

For a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm must be maintained so that the actuating range of the side lobes is not entered.

Attention:

The actuating range may vary depending on the substrate material and installation situation.

Work area

Repeat accuracy R
according to EN 60947-5-2<= 10

Electrical connection ratings

Current consumptionmax. 30 mA 
Fusing
external (operating voltage)0.25 … 8 A
Rated insulation voltage Ui75 V
Rated impulse withstand voltage Uimp1.5 kV
Operating voltage DC
UB24 V DC -15% … +15% regulated, residual ripple < 5%
Turn-on time
Safety outputsmax. 300 ms
EMC protection requirementsaccording to EN IEC 60947-5-3
Utilization category
DC-1324V 150mA 
Risk time according to EN 60947-5-3max. 260 ms
Safety classIII
Degree of contamination (external, according to EN 60947-1)3
Monitoring output OUT
Output typep-switching, short circuit-proof
Output voltage0.8 x UB … UB V DC
Switching currentmax. 50 mA
Safety outputs OA / OB
Output typeSemiconductor outputs, p-switching, short circuit-proof
rated conditional short-circuit current100 A
Discrepancy timemax. 10 ms
Output voltage
HIGH U(OA,OB)UB-1.5V … UB V DC 
LOW U(OA,OB)0 … 1 V DC
Switching current
per safety output1 … 150 mA
Off-state current Irmax. 0.25 mA
Test pulsesmax. 0.3 ms 
Test pulse intervalmin. 100 ms

Mechanical values and environment

ConnectionConnecting cable PUR, 0.2 m, with plug connector M12, 5-pin
Degree of protectionIP67
Ready delay0.5 s
Material
HousingPlastic, PBT
Dynamic bending radius10 x cable diameter
Static bending radius5 x cable diameter
Installation orientationany
Switching frequencymax. 1 Hz
Tightening torque
Fixing screwsmax. 1 Nm
Mounting distance
between 2 switches or 2 actuatorsmin. 400 mm
Mounting typeSurface mounting on metal
Shock and vibration resistanceaccording to EN IEC 60947-5-3
Cable ambient temperature (dynamic)-5 … +65 °C
Cable ambient temperature (static)-25 … +65 °C

Reliability values acc. to EN ISO 13849-1

Mission time20 y
Monitoring of the guard position
Category4
Performance LevelPL e
PFHD1.8 x 10-9

Miscellaneous

The following applies to the approval according to ULOperation only with UL Class 2 power supply or equivalent measures

In combination with actuator CES-A-BLN-R2-100776, CES-A-BLN-U2-103450, CES-A-BLN-L2-104510, CES-A-BLN-U2-112710

Assured operating distances saomin. 10 mm
Assured release distance sar
in y directionmax. 60 mm
in x/z directionmax. 40 mm
Operating distance15 mm
Switching hysteresis1 … 2 mm

In combination with actuator CES-A-BDN-06-104730

Assured operating distances saomin. 14 mm
Assured release distance sar
in x/z directionmax. 40 mm
in y directionmax. 60 mm
Operating distance19 mm
Switching hysteresis1 … 2 mm