Euchner EUCHNER CES-AR-C01-AH-SA

EUCHNER HBA-113815

EUCHNER CES-AR-C01-AH-SA

Euchner

EUCHNER CES-AR-C01-AH-SA

We are EUCHNER CES-AR-C01-AH-SA product supplier in India

ORDER NO. 098941

Order number098941
Item designationCES-AR-C01-AH-SA
Gross weight0,19kg
European Article Number (EAN)4047048005433
Customs tariff number85365019

Non-contact safety switch CES-AR-C01…

  • Safety switch with integrated evaluation electronics
  • Up to 20 switches in series
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Category 4 / PL e according to EN ISO 13849-1
  • Unicode

Approach direction

Can be adjusted in 90° steps

Short circuit monitoring

The switch generates its own clock signal on the output lines OA/OB. Pay attention to this aspect when connecting to control systems and relays.

Unicode evaluation

Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can be taught-in.

Only the last actuator taught-in is detected.

Category according to EN 13849-1

Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:

  • Category 4/PL e according to EN 13849-1

Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated.

LED indicator

STATEStatus LED
DIADiagnostics LED

Additional connections

OUTMonitoring output (semiconductor)
RSTReset input

Typical actuating range

With actuators CES-A-BBA and CES-A-BCA

<p>With actuators CES-A-BBA and CES-A-BCA</p>

For a side approach direction for the actuator and safety switch, a minimum distance of s = 4 mm must be maintained so that the actuating range of the side lobes is not entered.With actuator CES-A-BPAFor a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm must be maintained so that the actuating range of the side lobes is not entered.

Work area

Repeat accuracy R
according to EN 60947-5-2<= 10

Electrical connection ratings

Current consumption
no load on outputsmax. 50 mA
Fusing
external (operating voltage)0.25 … 8 A
Rated insulation voltage Ui300 V 
Rated impulse withstand voltage Uimp1.5 kV
Operating voltage DC
UB24 V DC -15% … +15% reverse polarity protected, regulated, residual ripple < 5%, PELV
Turn-on time
Safety outputsmax. 400 ms
EMC protection requirementsaccording to EN IEC 60947-5-3
Risk time according to EN 60947-5-3
Single devicemax. 260 ms
Risk time according to EN 60947-5-3, extension for each additional devicemax. 5 ms
Safety classIII
Degree of contamination (external, according to EN 60947-1)3
Monitoring output OUT
Output typep-switching, short circuit-proof
Output voltage0.8 x UB … UB V DC 
Switching currentmax. 200 mA
Safety outputs OA / OB
Output typeSemiconductor outputs, p-switching, short circuit-proof
rated conditional short-circuit currentmax. 100 A
Discrepancy timemax. 10 ms
Output voltage
HIGH U(OA,OB)UB-1.5 … UB V DC 
LOW U(OA,OB)0 … 1 V DC
Switching current
per safety output1 … 400 mA
Utilization category
DC-1324V 400mA 
Off-state current Irmax. 0.25 mA
Test pulsesmax. 1 ms

Mechanical values and environment

ConnectionM12 plug connector, 8-pin
Degree of protectionIP67
Ready delay10 s
Material
HousingPlastic, PBT
Installation orientationany
Switching frequencymax. 1 Hz
Tightening torque
Fixing screwsmax. 1 Nm
Mounting distancemin. 40 mm
Shock and vibration resistanceaccording to EN IEC 60947-5-3
Ambient temperature-20 … +55 °C

Reliability values acc. to EN ISO 13849-1

Mission time20 y
Monitoring of the guard position
Category4
Performance LevelPL e
PFHD2.1 x 10-9

Miscellaneous

The following applies to the approval according to ULOperation only with UL Class 2 power supply or equivalent measures

In combination with actuator CES-A-BDA-18-156935

Assured operating distances saomin. 10 mm 
Assured release distance sarmax. 45 mm 
Operating distance19 mm 
Switching hysteresis1 … 3 mm 
Mounting distance

In combination with actuator CES-A-BBA-071840

Assured operating distances saomin. 15 mm 
Assured release distance sarmax. 45 mm 
Operating distance18 mm
Switching hysteresis1 … 3 mm 
Mounting distance

In combination with actuator CES-A-BRN-100251

Assured operating distances saomin. 20 mm 
Assured release distance sarmax. 75 mm
Operating distance27 mm
Switching hysteresis3 mm 
Mounting distance

In combination with actuator CES-A-BPA-098775

Assured operating distances saomin. 18 mm
Assured release distance sarmax. 58 mm
Operating distance22 mm 
Switching hysteresis1 … 2 mm
Mounting distance
EUCHNER CES-AR-C01-AH-SA