ORDER NO. 117323
Order number | 117323 |
Item designation | CES-I-AP-M-C04-USI-117323 |
Gross weight | 0,081kg |
Customs tariff number | 85365019 |
Non-contact safety switches CES-I-AP-.-C04-, M12; pin 5 not used
- Safety switch with integrated evaluation electronics
- No series connection
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Category 4 / PL e according to EN ISO 13849-1
- Three active faces
- Connecting cable PUR, 0.1 m, plug connector M12, 5-pin; pin 5 not used
- Multicode
Installation position
Permissible installation position
Multicode evaluation
Every suitable actuator is detected by the switch.
Category according to EN 13849-1
Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
- Category 4/PL e according to EN 13849-1
Important: To achieve the stated category according to EN ISO 13849-1, both safety outputs (FO1A and FO1B) must be evaluated.
LED indicator
STATE | Status LED |
DIA | Diagnostics LED |
Connector assignment
Plug connector (view of connection side) | Pin | Designation | Function | Connecting cable conductor coloring |
---|---|---|---|---|
1 | UB | Power supply, DC 24 V | BN | |
2 | FO1A | Safety output, channel 1 | WH | |
3 | 0V | Ground, DC 0 V | BU | |
4 | FO1B | Safety output, channel 2 | BK | |
5 | – | n.c. | GY |
Work area
Repeat accuracy R | |
according to EN 60947-5-2 | <= 10 |
Electrical connection ratings
Current consumption | |
no load on outputs | max. 35 mA |
Fusing | |
external (operating voltage) | 0.25 … 8 A |
Rated insulation voltage Ui | 300 V |
Rated impulse withstand voltage Uimp | 1.5 kV |
Operating voltage DC | |
UB | 24 V DC -15% … +15% regulated, residual ripple < 5%, PELV |
Turn-on time | |
Safety outputs | max. 300 ms |
EMC protection requirements | according to EN IEC 60947-5-3 |
Risk time according to EN 60947-5-3 | max. 260 ms |
Safety class | III |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety outputs FO1A / FO1B | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
rated conditional short-circuit current | 100 A |
Discrepancy time | max. 10 ms |
Output voltage | |
HIGH U(FO1A) / U(FO1B) | UB-1.5V … UB V DC |
LOW U(FO1A) / U(FO1B) | 0 … 1 V DC |
Switching current | |
per safety output | 1 … 150 mA |
Utilization category | |
DC-13 | 24V 150mA |
Off-state current Ir | max. 0.25 mA |
Test pulses | max. 0.3 ms |
Test pulse interval | min. 100 ms |
Mechanical values and environment
Connection | PUR cable, 100mm, with plug connector M12x1, 5-pin; pin 5 not used |
Degree of protection | IP67 |
Ready delay | 0.5 s |
Material | |
Housing | Plastic, PBT |
Rubber support | NBR 80 ±5 Shore |
Dynamic bending radius | 10 x cable diameter |
Static bending radius | 5 x cable diameter |
Installation orientation | any |
Switching frequency | max. 1 Hz |
Tightening torque | |
Fixing screws | max. 0.8 Nm |
Mounting distance | |
between 2 switches or 2 actuators | min. 80 mm |
Mounting type | Surface mounting on metal |
Shock and vibration resistance | according to EN IEC 60947-5-3 |
Cable ambient temperature (dynamic) | -25 … +65 °C |
Cable ambient temperature (static) | -25 … +65 °C |
Reliability values acc. to EN ISO 13849-1
Mission time | 20 y |
Monitoring of the guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 4.1 x 10-9 |
Miscellaneous
Additional feature | Rubber support included |
The following applies to the approval according to UL | Operation only with UL Class 2 power supply or equivalent measures |
In combination with actuator CES-A-BDN-06-104730
Assured operating distances sao | |
Installation position C or D (broad side) | min. 10 mm |
Installation position A or B (front side) | min. 14 mm |
Assured release distance sar | |
in x/z direction | max. 40 mm |
in y direction | max. 60 mm |
Operating distance | |
Installation position C or D (broad side) | 15 mm |
Installation position A or B (front side) | 19 mm |
Switching hysteresis | 1 … 2 mm |
In combination with actuator CES-A-BBN-161502
Assured operating distances sao | |
in z direction / installation position A + B | min. 15 mm |
in x direction/installation position C + D | min. 10 mm |
Assured release distance sar | |
in y direction / installation position C + D | max. 72 mm |
in x/z direction / installation position A + B | max. 69 mm |
in y direction / installation position A + B | max. 77 mm |
in x/z direction / installation position C + D | max. 63 mm |
Operating distance | |
Installation position A + B | 30 mm |
Installation position C + D | 25 mm |
Switching hysteresis | |
in z direction / installation position A + B | 1 … 2 mm |
in x direction/installation position C + D | 1 … 2 mm |
In combination with actuator CES-A-BDN-06-161742
Assured operating distances sao | |
Installation position A | min. 16 mm |
Installation position C | min. 10 mm |
Assured release distance sar | |
Installation position A | max. 77 mm |
Installation position C | max. 72 mm |
Operating distance | |
Installation position A | 26 mm |
Installation position C | 23 mm |
Switching hysteresis | 1 … 2 mm |
In combination with actuator CES-A-BBN-C04-115271, CES-A-BBN-C04-EX-137527
Assured operating distances sao | |
Installation position C or D (broad side) | min. 6 mm |
Installation position A or B (front side) | min. 10 mm |
Assured release distance sar | |
in x/z direction | max. 40 mm |
in y direction | max. 60 mm |
Operating distance | |
Installation position C or D (broad side) | 11 mm |
Installation position A or B (front side) | 15 mm |
Switching hysteresis | 1 … 2 mm |