Euchner EUCHNER CES-I-AP-M-C04-USI-117323

EUCHNER HBA-113815

EUCHNER CES-I-AP-M-C04-USI-117323

Euchner

EUCHNER CES-I-AP-U-C04-USB-116502

We are EUCHNER CES-I-AP-M-C04-USI-117323 product supplier in India

ORDER NO. 117323

Order number117323
Item designationCES-I-AP-M-C04-USI-117323
Gross weight0,081kg
Customs tariff number85365019

Non-contact safety switches CES-I-AP-.-C04-, M12; pin 5 not used

  • Safety switch with integrated evaluation electronics
  • No series connection
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Category 4 / PL e according to EN ISO 13849-1
  • Three active faces
  • Connecting cable PUR, 0.1 m, plug connector M12, 5-pin; pin 5 not used
  • Multicode

Installation position

Permissible installation position

Multicode evaluation

Every suitable actuator is detected by the switch.

Category according to EN 13849-1

Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:

  • Category 4/PL e according to EN 13849-1

Important: To achieve the stated category according to EN ISO 13849-1, both safety outputs (FO1A and FO1B) must be evaluated.

LED indicator

STATEStatus LED
DIADiagnostics LED

Connector assignment

Plug connector (view of connection side)PinDesignationFunctionConnecting cable conductor coloring
1UBPower supply, DC 24 VBN
2FO1ASafety output, channel 1WH
30VGround, DC 0 VBU
4FO1BSafety output, channel 2BK
5n.c.GY

Work area

Repeat accuracy R
according to EN 60947-5-2<= 10

Electrical connection ratings

Current consumption
no load on outputsmax. 35 mA
Fusing
external (operating voltage)0.25 … 8 A
Rated insulation voltage Ui300 V
Rated impulse withstand voltage Uimp1.5 kV
Operating voltage DC
UB24 V DC -15% … +15% regulated, residual ripple < 5%, PELV 
Turn-on time
Safety outputsmax. 300 ms
EMC protection requirementsaccording to EN IEC 60947-5-3
Risk time according to EN 60947-5-3max. 260 ms
Safety classIII
Degree of contamination (external, according to EN 60947-1)3
Safety outputs FO1A / FO1B
Output typeSemiconductor outputs, p-switching, short circuit-proof
rated conditional short-circuit current100 A
Discrepancy timemax. 10 ms
Output voltage
HIGH U(FO1A) / U(FO1B)UB-1.5V … UB V DC 
LOW U(FO1A) / U(FO1B)0 … 1 V DC
Switching current
per safety output1 … 150 mA
Utilization category
DC-1324V 150mA 
Off-state current Irmax. 0.25 mA
Test pulsesmax. 0.3 ms 
Test pulse intervalmin. 100 ms

Mechanical values and environment

ConnectionPUR cable, 100mm, with plug connector M12x1, 5-pin; pin 5 not used
Degree of protectionIP67
Ready delay0.5 s
Material
HousingPlastic, PBT
Rubber supportNBR 80 ±5 Shore
Dynamic bending radius10 x cable diameter
Static bending radius5 x cable diameter
Installation orientationany
Switching frequencymax. 1 Hz
Tightening torque
Fixing screwsmax. 0.8 Nm
Mounting distance
between 2 switches or 2 actuatorsmin. 80 mm
Mounting typeSurface mounting on metal
Shock and vibration resistanceaccording to EN IEC 60947-5-3
Cable ambient temperature (dynamic)-25 … +65 °C
Cable ambient temperature (static)-25 … +65 °C

Reliability values acc. to EN ISO 13849-1

Mission time20 y
Monitoring of the guard position
Category4
Performance LevelPL e
PFHD4.1 x 10-9

Miscellaneous

Additional featureRubber support included
The following applies to the approval according to ULOperation only with UL Class 2 power supply or equivalent measures

In combination with actuator CES-A-BDN-06-104730

Assured operating distances sao
Installation position C or D (broad side)min. 10 mm
Installation position A or B (front side)min. 14 mm
Assured release distance sar
in x/z directionmax. 40 mm
in y directionmax. 60 mm
Operating distance
Installation position C or D (broad side)15 mm
Installation position A or B (front side)19 mm
Switching hysteresis1 … 2 mm

In combination with actuator CES-A-BBN-161502

Assured operating distances sao
in z direction / installation position A + Bmin. 15 mm
in x direction/installation position C + Dmin. 10 mm
Assured release distance sar
in y direction / installation position C + Dmax. 72 mm
in x/z direction / installation position A + Bmax. 69 mm
in y direction / installation position A + Bmax. 77 mm
in x/z direction / installation position C + Dmax. 63 mm
Operating distance
Installation position A + B30 mm
Installation position C + D25 mm
Switching hysteresis
in z direction / installation position A + B1 … 2 mm
in x direction/installation position C + D1 … 2 mm

In combination with actuator CES-A-BDN-06-161742

Assured operating distances sao
Installation position Amin. 16 mm
Installation position Cmin. 10 mm
Assured release distance sar
Installation position Amax. 77 mm
Installation position Cmax. 72 mm
Operating distance
Installation position A26 mm
Installation position C23 mm
Switching hysteresis1 … 2 mm

In combination with actuator CES-A-BBN-C04-115271, CES-A-BBN-C04-EX-137527

Assured operating distances sao
Installation position C or D (broad side)min. 6 mm
Installation position A or B (front side)min. 10 mm
Assured release distance sar
in x/z directionmax. 40 mm
in y directionmax. 60 mm
Operating distance
Installation position C or D (broad side)11 mm
Installation position A or B (front side)15 mm
Switching hysteresis1 … 2 mm
Still not sure what you want?

We are here to help you, send us your details we will assist you to choose right product.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Know the part number Search here
EUCHNER CES-I-AP-U-C04-USB-116502

EUCHNER CES-I-AP-M-C04-USI-117323

Fill up the form and we will get back to you in few hours with right details. fill the form to help you better way.