We are EUCHNER CES-I-AP-U-C04-USB-116502 product supplier in India
ORDER NO. 116502
Order number
116502
Item designation
CES-I-AP-U-C04-USB-116502
Gross weight
0,086kg
Customs tariff number
85365019
Non-contact safety switches CES-I-AP-.-C04-…, M12
Safety switch with integrated evaluation electronics
No series connection
Short circuit monitoring
2 safety outputs (semiconductor outputs)
Category 4 / PL e according to EN ISO 13849-1
Three active faces
Connecting cable PUR, 0.22 m, plug connector M12, 5-core
Unicode
Monitoring output OD
Installation position
Permissible installation position
Unicode evaluation
Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can be taught-in. Only the last actuator taught-in is detected.
Category according to EN 13849-1
Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
Category 4/PL e according to EN 13849-1
Important: To achieve the stated category according to EN ISO 13849-1, both safety outputs (FO1A and FO1B) must be evaluated.
LED indicator
STATE
Status LED
DIA
Diagnostics LED
Connector assignment
Plug connector (view of connection side)
Pin
Designation
Function
Connecting cable conductor coloring
1
UB
Power supply, DC 24 V
BN
2
FO1A
Safety output, channel 1
WH
3
0V
Ground, DC 0 V
BU
4
FO1B
Safety output, channel 2
BK
5
OD
Monitoring output
GY
Work area
Repeat accuracy R
according to EN 60947-5-2
<= 10
Electrical connection ratings
Current consumption
no load on outputs
max. 35 mA
Fusing
external (operating voltage)
0.25 … 8 A
Rated insulation voltage Ui
300 V
Rated impulse withstand voltage Uimp
1.5 kV
Operating voltage DC
UB
24 V DC -15% … +15% regulated, residual ripple < 5%, PELV
Turn-on time
Safety outputs
max. 300 ms
EMC protection requirements
according to EN IEC 60947-5-3
Risk time according to EN 60947-5-3
max. 260 ms
Safety class
III
Degree of contamination (external, according to EN 60947-1)
3
Monitoring output OD
Output type
p-switching, short circuit-proof
Output voltage
0.8 x UB … UB V DC
Switching current
max. 50 mA
Safety outputs FO1A / FO1B
Output type
Semiconductor outputs, p-switching, short circuit-proof
rated conditional short-circuit current
100 A
Discrepancy time
max. 10 ms
Output voltage
HIGH U(FO1A) / U(FO1B)
UB-1.5V … UB V DC
LOW U(FO1A) / U(FO1B)
0 … 1 V DC
Switching current
per safety output
1 … 150 mA
Utilization category
DC-13
24V 150mA
Off-state current Ir
max. 0.25 mA
Test pulses
max. 0.3 ms
Test pulse interval
min. 100 ms
Mechanical values and environment
Connection
PUR cable, 200 mm, with plug connector M12x1, 5-pin
Degree of protection
IP67
Ready delay
0.5 s
Material
Rubber support
NBR 80 ±5 Shore
Housing
Plastic, PBT
Dynamic bending radius
10 x cable diameter
Static bending radius
5 x cable diameter
Installation orientation
any
Switching frequency
max. 1 Hz
Tightening torque
Fixing screws
max. 0.8 Nm
Mounting distance
between 2 switches or 2 actuators
min. 80 mm
Mounting type
Surface mounting on metal
Shock and vibration resistance
according to EN IEC 60947-5-3
Cable ambient temperature (dynamic)
-25 … +65 °C
Cable ambient temperature (static)
-25 … +65 °C
Reliability values acc. to EN ISO 13849-1
Mission time
20 y
Monitoring of the guard position
Category
4
Performance Level
PL e
PFHD
4.1 x 10-9
Miscellaneous
Additional feature
Rubber support included
The following applies to the approval according to UL
Operation only with UL Class 2 power supply or equivalent measures
In combination with actuator CES-A-BBN-161502
Assured operating distances sao
in z direction / installation position A + B
min. 15 mm
in x direction/installation position C + D
min. 10 mm
Assured release distance sar
in y direction / installation position C + D
max. 72 mm
in y direction / installation position A + B
max. 77 mm
in x/z direction / installation position C + D
max. 63 mm
in x/z direction / installation position A + B
max. 69 mm
Operating distance
Installation position C + D
25 mm
Installation position A + B
30 mm
Switching hysteresis
in z direction / installation position A + B
1 … 2 mm
in x direction/installation position C + D
1 … 2 mm
In combination with actuator CES-A-BDN-06-104730
Assured operating distances sao
Installation position A or B (front side)
min. 14 mm
Installation position C or D (broad side)
min. 10 mm
Assured release distance sar
in y direction
max. 60 mm
in x/z direction
max. 40 mm
Operating distance
Installation position C or D (broad side)
15 mm
Installation position A or B (front side)
19 mm
Switching hysteresis
1 … 2 mm
In combination with actuator CES-A-BDN-06-161742
Assured operating distances sao
Installation position A
min. 16 mm
Installation position C
min. 10 mm
Assured release distance sar
Installation position A
max. 77 mm
Installation position C
max. 72 mm
Operating distance
Installation position A
26 mm
Installation position C
23 mm
Switching hysteresis
1 … 2 mm
In combination with actuator CES-A-BBN-C04-115271, CES-A-BBN-C04-EX-137527
Assured operating distances sao
Installation position A or B (front side)
min. 10 mm
Installation position C or D (broad side)
min. 6 mm
Assured release distance sar
in y direction
max. 60 mm
in x/z direction
max. 40 mm
Operating distance
Installation position C or D (broad side)
11 mm
Installation position A or B (front side)
15 mm
Switching hysteresis
1 … 2 mm