Order number113272
Item designationCET1-AR-CRA-CH-50F-SG-C2333-113272
Gross weight1,346kg
Customs tariff number85365019

Non-contact safety switch CET-AR-…, M12, with escape release and lockout bar

  • Safety switch with guard locking and integrated evaluation electronics
  • Locking force up to 6,500 N
  • Up to 20 switches in series
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Category 4 / PL e according to EN ISO 13849-1
  • With 2 plug connectors M12
  • Multicode
  • Escape release, 75 mm long
  • Lockout mechanism
  • Multicode
  • Approach direction A (delivery state)

Approach direction

Horizontal

Can be adjusted in 90° steps

Escape release

This is used for manual release of guard locking from the danger zone without tools.

Lockout mechanism

The lockout bar can be used to prevent maintenance personnel from being unintentionally locked in the danger zone, for example.

Important: The lockout bar is not a safety function.

This device with lockout bar possesses no auxiliary release.

Safety switch

The device may be operated only in conjunction with the actuator CET-A-….

Important: The actuator must be ordered separately.

Multicode evaluation unit

Every suitable actuator is detected by the switch.

Solenoid operating voltage

  • DC 24 V +10%, -15%

Guard locking type

CET1Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid.

LED function display

State LEDStatus LED
DIA LEDDiagnostics LED
LED 1 rdfreely configurable
LED 2 gnfreely configurable

Additional connections

OUTMonitoring output (semiconductor)
RSTReset input

Category according to EN ISO 13849-1

Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:

  • Category 4 / PL e according to EN ISO 13849-1
  • The stated safety characteristics apply to any installation orientations of the safety switch.

Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated.

Work area

Repeat accuracy R
according to EN 60947-5-210 %

Electrical connection ratings

Power consumption
Solenoid11 W
Current consumption
ICM450 mA
IB80 mA
Fusing
external (operating voltage UB)0.25 … 8 A
external (operating voltage UCM)0.5 … 8 A
Operating voltage DC
LED1, LED224 V DC -15% V DC … +10% V DC
UB24 V DC -15% … +15% reverse polarity protected, regulated, residual ripple < 5%, PELV
EMC protection requirementsaccording to EN IEC 60947-5-3
Utilization category
DC-1324V 200mA 
Solenoid operating voltage DC
UCM24 V DC -15% … +10% reverse polarity protected, regulated, residual ripple < 5%, PELV
Solenoid duty cycle100 %
Switching load
according to UL24V DC, Class 2 
Safety class
EN IEC 61140III
Test pulsesmax. 1 ms 
Degree of contamination (external, according to EN 60947-1)3
Monitoring output OUT
Output typeSemiconductor output, p-switching, short circuit-proof
Output current
OUT1 … 50 mA
Output voltage
OUT0.8xUB … UB V DC
Safety outputs OA / OB
Output typeSemiconductor outputs, p-switching, short circuit-proof
Output current
per safety output1 … 200 mA
Discrepancy time
both safety outputsmax. 10 ms
Output voltage
HIGH U(OA,OB)UB-1.5V … UB V DC 
LOW U(OA,OB)0 … 1 V DC
Turn-on time
Safety outputs400 ms
Off-state current Irmax. 0.25 mA
Risk time according to EN 60947-5-3
Single devicemax. 400 ms
Risk time according to EN 60947-5-3, extension for each additional devicemax. 5 ms

Mechanical values and environment

Approach speedmax. 20 m/min
Connection2 plug connectors M12, 5- and 8-pin
Degree of protectionIP67 
Ready delay10 s
Material
Rampstainless steel
Safety switch housingDie-cast aluminum
Mechanical life2 x 10⁶
Installation orientationany 
Switching frequencymax. 0.5 Hz
Degree of freedom X±5 mm
Degree of freedom Y±5 mm
Degree of freedom Z±4 mm
Shock and vibration resistanceaccording to EN IEC 60947-5-3
Ambient temperature
at UB = 24V DC-20 … +55 °C
Locking force Fmax6500 N
Locking force FZh5000 N
Guard locking principleClosed-circuit current principle

Reliability values acc. to EN ISO 13849-1

Mission time20 y
Control of guard locking
CategoryDepending on external control of guard locking
Performance LevelDepending on external control of guard locking 
PFHDDepending on external control of guard locking 
Monitoring of guard locking and the guard position
Category
Any installation orientation4
Performance LevelPL e
PFHD
Any installation orientation3.1 x 10-9

Miscellaneous

C number
C2333with mounted lockout mechanism
The following applies to the approval according to ULOperation only with UL Class 2 power supply or equivalent measures; see operating instructions
Still not sure what you want?

We are here to help you, send us your details we will assist you to choose right product.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Know the part number Search here
EUCHNER CET1-AR-CRA-CH-50F-SG-C2333-113272

EUCHNER CET1-AR-CRA-CH-50F-SG-C2333-113272

Fill up the form and we will get back to you in few hours with right details. fill the form to help you better way.