We are EUCHNER CET3-AP-CRA-AH-50X-SA-122398 product supplier in India
ORDER NO. 122398
Order number
122398
Item designation
CET3-AP-CRA-AH-50X-SA-122398
Gross weight
1,273kg
Customs tariff number
85365019
Non-contact safety switch CET-AP-…, M12
Safety switch with guard locking and integrated evaluation electronics
Locking force up to 6,500 N
Short circuit monitoring
2 safety outputs (semiconductor outputs)
Category 4 / PL e according to EN ISO 13849-1
With 1 plug connector M12, 8-pin
Unicode
Door monitoring output
Indication of the door position by LED
Approach direction A (delivery state)
Approach direction
Horizontal
Can be adjusted in 90° steps
Safety switch
The device may be operated only in conjunction with the actuator CET-A-….
Important: The actuator must be ordered separately.
Unicode evaluation
Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can be taught-in. Only the last actuator taught-in is detected.
Solenoid operating voltage
DC 24 V +10%, -15%
Guard locking type
CET3
Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid. The door position is also monitored. The door monitoring output OUT D is set to HIGH as soon as the actuator is above the extended plunger (state: door closed, guard locking not active). OUT output D also remains set when guard locking is active.
LED function display
State LED
Status LED
DIA LED
Diagnostics LED
LED 1 rd
illuminates when the solenoid is energized
LED 2 gn
illuminates when door is closed
Additional connections
OUT
Monitoring output (semiconductor)
OUT D
Door monitoring output
Category according to EN ISO 13849-1
Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
Category 4 / PL e according to EN ISO 13849-1
The stated safety characteristics apply to any installation orientations of the safety switch.
Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated.
Work area
Repeat accuracy R
according to EN 60947-5-2
10 %
Electrical connection ratings
Power consumption
Solenoid
11 W
Connecting cable
30V DC, 2A
Current consumption
ICM
450 mA
IB
80 mA
Fusing
external (operating voltage UB)
0.25 … 8 A
external (solenoid operating voltage UCM)
0.5 … 8 A
Operating voltage DC
LED
24 V DC -15% V DC … +10% V DC
UB
24 V DC -15% … +15% reverse polarity protected, regulated, residual ripple < 5%, PELV
EMC protection requirements
according to EN IEC 60947-5-3
Utilization category
DC-13
24V 200mA
Solenoid operating voltage DC
UCM
24 V DC -15% … +10% reverse polarity protected, regulated, residual ripple < 5%, PELV
Solenoid duty cycle
100 %
Switching load
according to UL
24V DC, Class 2
Safety class
EN IEC 61140
III
Test pulses
max. 0.3 ms
Degree of contamination (external, according to EN 60947-1)
3
Monitoring output OUT D
Output type
p-switching, short circuit-proof
Output voltage
OUT D
0.8xUB … UB V DC
Switching current
OUT D
1 … 50 mA
Switching delay from state change
max. 700 ms
Monitoring output OUT
Output type
p-switching, short circuit-proof
Output voltage
OUT
0.8xUB … UB V DC
Switching current
OUT
1 … 50 mA
Switching delay from state change
max. 400 ms
Mechanical values and environment
Approach speed
max. 20 m/min
Connection
1 plug connector M12, 8-pin
Degree of protection
IP67
Ready delay
1 s
Material
Ramp
stainless steel
Safety switch housing
Die-cast aluminum
Mechanical life
2 x 10⁶
Installation orientation
any
Switching frequency
max. 0.5 Hz
Degree of freedom X
±5 mm
Degree of freedom Y
±5 mm
Degree of freedom Z
±4 mm
Shock and vibration resistance
according to EN IEC 60947-5-3
Ambient temperature
at UB = 24V DC
-20 … +55 °C
Locking force Fmax
6500 N
Locking force FZh
5000 N
Guard locking principle
Closed-circuit current principle
Reliability values acc. to EN ISO 13849-1
Mission time
20 y
Control of guard locking
Category
Depending on external control of guard locking
Performance Level
Depending on external control of guard locking
PFHD
Depending on external control of guard locking
Monitoring of guard locking and the guard position
Category
Any installation orientation
4
Performance Level
PL e
PFHD
Any installation orientation
3.1 x 10-9
Miscellaneous
The following applies to the approval according to UL
Operation only with UL Class 2 power supply or equivalent measures; see operating instructions
Still not sure what you want?
We are here to help you, send us your details we will assist you to choose right product.
Know the part number Search here
EUCHNER CET3-AP-CRA-AH-50X-SA-122398
Fill up the form and we will get back to you in few hours with right details. fill the form to help you better way.