Search
Close this search box.

WE HANDLE INQUIRIES THROUGH EMAIL MORE EFFICIENTLY

WE HANDLE INQUIRIES THROUGH EMAIL MORE EFFICIENTLY

Euchner EUCHNER CMS-E-ER

EUCHNER HBA-113815

EUCHNER CMS-E-ER

Euchner

EUCHNER CMS-E-ER

We are EUCHNER CMS-E-ER product supplier in India

ORDER NO. 099182

Order number099182
Item designationCMS-E-ER
Gross weight0,225kg
Customs tariff number85364110

Evaluation unit CMS-E-ER, 2 safety contacts, 1 auxiliary contact, 1 feedback loop can be connected

  • Up to 30 read heads can be connected
  • 2 safety contacts
  • 1 auxiliary contact
  • 1 feedback loop can be connected
  • Start automatic/monitored/not monitored

Functional description

The evaluation unit CMS-E-ER is suitable for the direct connection of up to 30 read heads.

Category/PL according to EN ISO 13849-1

  • Category 4/PL e with only one read head connected
  • Max. category 3/PL d with more than one connected read head

Notice:

At low approach speeds in the z direction, the time offset when switching the reed contacts must not be more than 0.6 ms.

Controls and indicators

LED indicator1 indicator LED Power (UB) and 2 status indicators for the read heads (K1/K2)

Electrical connection ratings

Breaking capacity (VA)
Safety contacts 13/14, 23/24max. 720 VA
Connection cross-section0.14 … 2.5 mm²
Current consumption
at DC 24V10 … 110 mA
Fusing
Protection internal (operating voltage UB)0.75 A Automatically resetting fuse PTC
External contact fuse (safety circuit) acc. to EN IEC 60269-14A gG
Rated insulation voltage Ui
AC250 V
Operating voltage
AC/DC-10% … 24 … +10% V 
Outputs
NumberTypeFunctionFootnote1Relay contacts, floatingAuxiliary contacts 31/322Relay contacts, floatingSafety contacts 13/14, 23/24
Switching current
Safety contacts 13/14, 23/2410 … 3000 mA at DC 24V
Auxiliary contacts 31/32max. 1500 mA at DC 24V
Switching voltage
Safety contacts 13/14, 23/24max. AC 240 V
Utilization category
AC-13A, 230V; 3A, 24V 
AC-150.9A , 240V and 0.9A , 24V 
DC-131.5A, 24V 
Risk time according to EN 60947-5-3max. 20 ms
Switching load
According to UL class 2Input: 24 V AC/DC; output: 30 V AC, 24 V DC
Degree of contamination (external, according to EN 60947-1)2

Mechanical values and environment

Approach direction
ConnectionConnection terminals
Degree of protectionTerminals IP20 / housing IP40
Material
HousingPolyamide PA6.6
Mechanical life10 x 10⁶
Mounting typeMounting rail 35 mm according to DIN EN 60715 TH35
Ambient temperature0 … +55 °C

Reliability values acc. to EN ISO 13849-1

Number of switching cycles
≤ 0.1A at 24V DC166000 1/y
≤ 1A at 24V DC70000 1/y
Mission time20 y 
Monitoring of the guard position with 1 read head
Category
Performance LevelPL e 
PFHD2.5 x 10-8 
Monitoring of the guard position with >1 read head
Category
Performance LevelPL d 
PFHD1.0 x 10-7 

Miscellaneous

in compliance withEN ISO 13849-1: 2015; EN ISO 13849-2:2012; EN 50178: 1997; EN 60204-1: 2006/A1: 2009; EN ISO 13850: 2015; EN 14119:2013; EN 6100-6-2: 2005; EN 6100-6-3: 2007/A1: 2011; EN 60947-5-3: 2013

In combination with read head CMS-R-CXC-03V, CMS-R-CXC-05V, CMS-R-CXC-05P, CMS-R-CXC-SC and actuator CMS-M-CA

Assured operating distances sao
with center offset m=0min. 6 mm 
Assured release distance sarmax. 14 mm 
Center offset
at s=3 mm read distance2,5 mm 

In combination with read head CMS-R-AXH-03V, CMS-R-AXH-05V, CMS-R-AXH-SC, CMS-R-AXH-05P and actuator CMS-M-AC

Assured operating distances sao
with center offset m=0min. 6 mm 
Assured release distance sarmax. 31 mm 
Center offset
at s=3 mm read distance2,5 mm 

In combination with read head CMS-R-BXI-03V, CMS-R-BXI-05V, CMS-R-BXI-SC, CMS-R-BXI-07P and actuator CMS-M-BD

Assured operating distances sao
with center offset m=0min. 3 mm 
Assured release distance sarmax. 12 mm 
Center offset
at s=3 mm read distance2,5 mm 

In combination with read head CMS-RH-BYB-03VL, CMS-RH-BYB-05VL and actuator CMS-MH-BB

Assured operating distances sao
with center offset m=0min. 6 mm 
Assured release distance sarmax. 13 mm 
Center offset
at s=3 mm read distance2,5 mm 

In combination with read head CMS-R-EXM-03V, CMS-R-EXM-05V, CMS-R-EXM-SC and actuator CMS-M-EF

Assured operating distances sao
with center offset m=0min. 6 mm 
Assured release distance sarmax. 17 mm 
Center offset
at s=3 mm read distance2,5 mm 

In combination with read head CMS-RH-AYA-03VL, CMS-RH-AYA-05VL and actuator CMS-MH-AA

Assured operating distances sao
with center offset m=0min. 10 mm 
Assured release distance sarmax. 20 mm 
Center offset
at s=3 mm read distance2,5 mm 
Still not sure what you want?

We are here to help you, send us your details we will assist you to choose right product.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Know the part number Search here
EUCHNER CMS-E-ER

EUCHNER CMS-E-ER

Fill up the form and we will get back to you in few hours with right details. fill the form to help you better way.