085736
Read heads CMS design A – with NC/NO contacts, PVC
- In combination with evaluation units CMS-E-BR/CMS-E-ER/CMS-E-FR
- Cube-shaped version, 88 x 25 mm
- Connecting cable
- Cable type: PVC
Alignment of read head and actuator

Operating diagram, design A

CMS-R-AXH
- Typ. operating distance
- Typ. release distance
Technical Data
Work area
| Assured operating distance sao | |
| with center offset m=0 | min. 6 mm |
| Assured release distance sar | max. 31 mm |
| Repeat accuracy R | max. 10 % |
Electrical connection ratings
| Rated impulse withstand voltage Uimp | 1.5 kV |
| Rated insulation voltage Ui | 26.4 V |
| Switching characteristics | NO + NC |
| Switching current | 8 … 500 mA |
| Switching voltage | 24 V |
| Switching voltage according to UL | |
| according to UL Class 2 | max. 24 V AC/DC |
Mechanical values and environment
| Ambient temperature | -20 … +60 °C |
| Cable length | 5 m |
| Connection | hard-wired encapsulated cable with cable end sleeves, 0.34 mmSUP2/SUP |
| Degree of protection | IP67 |
| Design | A |
| Installation orientation | any |
| Material | |
| Cable material | PVC |
| Housing | Fiber glass reinforced PPS |
| Mechanical life | 100 x 10⁶ |
| Method of operation | magnetic, reed contact |
| Number NC contacts | 1 NC contact |
| Number of NO contacts | 1 NO contacts |
| Shock and vibration resistance | according to EN 60947-5-3 |
| Tightening torque | 0.4 … 0.5 Nm |
Miscellaneous
| in compliance with | EN ISO 13849-1:2015; EN 50178:1997; EN 60204-1:2006/A1:2009; EN ISO 14119:2013; EN 61000-6-2:2005; EN 61000-6-3:2007/A1:2011; EN 60947-5-3:2013 |