085736
Read heads CMS design A – with NC/NO contacts, PVC
- In combination with evaluation units CMS-E-BR/CMS-E-ER/CMS-E-FR
- Cube-shaped version, 88 x 25 mm
- Connecting cable
- Cable type: PVC
Alignment of read head and actuator
Operating diagram, design A
CMS-R-AXH
- Typ. operating distance
- Typ. release distance
Technical Data
Work area
Assured operating distance sao | |
with center offset m=0 | min. 6 mm |
Assured release distance sar | max. 31 mm |
Repeat accuracy R | max. 10 % |
Electrical connection ratings
Rated impulse withstand voltage Uimp | 1.5 kV |
Rated insulation voltage Ui | 26.4 V |
Switching characteristics | NO + NC |
Switching current | 8 … 500 mA |
Switching voltage | 24 V |
Switching voltage according to UL | |
according to UL Class 2 | max. 24 V AC/DC |
Mechanical values and environment
Ambient temperature | -20 … +60 °C |
Cable length | 5 m |
Connection | hard-wired encapsulated cable with cable end sleeves, 0.34 mmSUP2/SUP |
Degree of protection | IP67 |
Design | A |
Installation orientation | any |
Material | |
Cable material | PVC |
Housing | Fiber glass reinforced PPS |
Mechanical life | 100 x 10⁶ |
Method of operation | magnetic, reed contact |
Number NC contacts | 1 NC contact |
Number of NO contacts | 1 NO contacts |
Shock and vibration resistance | according to EN 60947-5-3 |
Tightening torque | 0.4 … 0.5 Nm |
Miscellaneous
in compliance with | EN ISO 13849-1:2015; EN 50178:1997; EN 60204-1:2006/A1:2009; EN ISO 14119:2013; EN 61000-6-2:2005; EN 61000-6-3:2007/A1:2011; EN 60947-5-3:2013 |