ORDER NO. 109358
Order number | 109358 |
Item designation | RIEGEL CES-AC-AR-C01-AH-SA-C2296 |
Gross weight | 2,133kg |
European Article Number (EAN) | 4047048007215 |
Customs tariff number | 83014090 |
Bolt CES-AC-AR-C01-AH-SA-C2296
- Steel bolt
- Safety switch already pre-assembled
- Connection via M12 plug connector
- For doors hinged on the left or right
- Ball detent mechanism in closed position
- Can be locked in open position with padlocks
- Switch and actuator included
- Protective plate for safety switch
Benefits
- Robust design
- Easily mounted to standard aluminum profiles and machine covers by screw connection
- Distinctive yellow color for easy recognition
- Symmetrical design for doors hinged on the right or left
- No additional door handle necessary
Notes
- CES actuator integrated in the bolt tongue
- Safety switch CES-AR-C01-AH-SA-098941 included. For further information see product page for the safety switch.
Special features
- Highly coded actuator (unicode) – maximum protection against tampering
- Bolt with detent mechanism – Ball detent mechanism in closed bolt position – Protection against vibration
Mechanical values and environment
Approach direction | A or C |
Number of safety switches that can be mounted | 1 |
Material | |
Guide strips | Plastic |
Switch bracket | Steel powder-coated |
Handle | Plastic |
Base plate | Galvanized steel |
Escape release | yes |
Miscellaneous
C number | |
C2296 | Gap dimension 7mm |
Detent mechanism closed position | Ball detent mechanism |
Switch CES-AR-C01-AH-SA (Order no. 098941)
Work area
Repeat accuracy R | |
according to EN 60947-5-2 | <= 10 |
Electrical connection ratings
Current consumption | |
no load on outputs | max. 50 mA |
Fusing | |
external (operating voltage) | 0.25 … 8 A |
Rated insulation voltage Ui | 300 V |
Rated impulse withstand voltage Uimp | 1.5 kV |
Operating voltage DC | |
UB | 24 V DC -15% … +15% reverse polarity protected, regulated, residual ripple < 5%, PELV |
Turn-on time | |
Safety outputs | max. 400 ms |
EMC protection requirements | according to EN IEC 60947-5-3 |
Risk time according to EN 60947-5-3 | |
Single device | max. 260 ms |
Risk time according to EN 60947-5-3, extension for each additional device | max. 5 ms |
Safety class | III |
Degree of contamination (external, according to EN 60947-1) | 3 |
Monitoring output OUT | |
Output type | p-switching, short circuit-proof |
Output voltage | 0.8 x UB … UB V DC |
Switching current | max. 200 mA |
Safety outputs OA / OB | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
rated conditional short-circuit current | max. 100 A |
Discrepancy time | max. 10 ms |
Output voltage | |
LOW U(OA,OB) | 0 … 1 V DC |
HIGH U(OA,OB) | UB-1.5 … UB V DC |
Switching current | |
per safety output | 1 … 400 mA |
Utilization category | |
DC-13 | 24V 400mA |
Off-state current Ir | max. 0.25 mA |
Test pulses | max. 1 ms |
Mechanical values and environment
Connection | M12 plug connector, 8-pin |
Degree of protection | IP67 |
Ready delay | 10 s |
Material | |
Housing | Plastic, PBT |
Installation orientation | any |
Switching frequency | max. 1 Hz |
Tightening torque | |
Fixing screws | max. 1 Nm |
Mounting distance | min. 40 mm |
Shock and vibration resistance | according to EN IEC 60947-5-3 |
Ambient temperature | -20 … +55 °C |
Reliability values acc. to EN ISO 13849-1
Mission time | 20 y |
Monitoring of the guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 2.1 x 10-9 |
Miscellaneous
The following applies to the approval according to UL | Operation only with UL Class 2 power supply or equivalent measures |