Euchner EUCHNER RIEGEL CES-AC-AR-C01-AH-SA-C2296

EUCHNER HBA-113815

EUCHNER RIEGEL CES-AC-AR-C01-AH-SA-C2296

Euchner

EUCHNER RIEGEL CES-AC-AR-C01-AH-SA-C2296

We are EUCHNER RIEGEL CES-AC-AR-C01-AH-SA-C2296 product supplier in India

ORDER NO. 109358

Order number109358
Item designationRIEGEL CES-AC-AR-C01-AH-SA-C2296
Gross weight2,133kg
European Article Number (EAN)4047048007215
Customs tariff number83014090

Bolt CES-AC-AR-C01-AH-SA-C2296

  • Steel bolt
  • Safety switch already pre-assembled
  • Connection via M12 plug connector
  • For doors hinged on the left or right
  • Ball detent mechanism in closed position
  • Can be locked in open position with padlocks
  • Switch and actuator included
  • Protective plate for safety switch

Benefits

  • Robust design
  • Easily mounted to standard aluminum profiles and machine covers by screw connection
  • Distinctive yellow color for easy recognition
  • Symmetrical design for doors hinged on the right or left
  • No additional door handle necessary

Notes

  • CES actuator integrated in the bolt tongue
  • Safety switch CES-AR-C01-AH-SA-098941 included. For further information see product page for the safety switch.

Special features

  • Highly coded actuator (unicode) – maximum protection against tampering
  • Bolt with detent mechanism – Ball detent mechanism in closed bolt position – Protection against vibration

Mechanical values and environment

Approach directionA or C
Number of safety switches that can be mounted1
Material
Guide stripsPlastic
Switch bracketSteel powder-coated
HandlePlastic
Base plateGalvanized steel
Escape releaseyes

Miscellaneous

C number
C2296Gap dimension 7mm
Detent mechanism closed positionBall detent mechanism

Switch CES-AR-C01-AH-SA (Order no. 098941)

Switch CES-AR-C01-AH-SA  (Order no. 098941)

Work area

Repeat accuracy R
according to EN 60947-5-2<= 10

Electrical connection ratings

Current consumption
no load on outputsmax. 50 mA
Fusing
external (operating voltage)0.25 … 8 A
Rated insulation voltage Ui300 V 
Rated impulse withstand voltage Uimp1.5 kV
Operating voltage DC
UB24 V DC -15% … +15% reverse polarity protected, regulated, residual ripple < 5%, PELV
Turn-on time
Safety outputsmax. 400 ms
EMC protection requirementsaccording to EN IEC 60947-5-3
Risk time according to EN 60947-5-3
Single devicemax. 260 ms
Risk time according to EN 60947-5-3, extension for each additional devicemax. 5 ms
Safety classIII
Degree of contamination (external, according to EN 60947-1)3
Monitoring output OUT
Output typep-switching, short circuit-proof
Output voltage0.8 x UB … UB V DC 
Switching currentmax. 200 mA
Safety outputs OA / OB
Output typeSemiconductor outputs, p-switching, short circuit-proof
rated conditional short-circuit currentmax. 100 A
Discrepancy timemax. 10 ms
Output voltage
LOW U(OA,OB)0 … 1 V DC
HIGH U(OA,OB)UB-1.5 … UB V DC 
Switching current
per safety output1 … 400 mA
Utilization category
DC-1324V 400mA 
Off-state current Irmax. 0.25 mA
Test pulsesmax. 1 ms

Mechanical values and environment

ConnectionM12 plug connector, 8-pin
Degree of protectionIP67
Ready delay10 s
Material
HousingPlastic, PBT
Installation orientationany
Switching frequencymax. 1 Hz
Tightening torque
Fixing screwsmax. 1 Nm
Mounting distancemin. 40 mm
Shock and vibration resistanceaccording to EN IEC 60947-5-3
Ambient temperature-20 … +55 °C

Reliability values acc. to EN ISO 13849-1

Mission time20 y
Monitoring of the guard position
Category4
Performance LevelPL e
PFHD2.1 x 10-9

Miscellaneous

The following applies to the approval according to ULOperation only with UL Class 2 power supply or equivalent measures
EUCHNER RIEGEL CES-AC-AR-C01-AH-SA-C2296

EUCHNER RIEGEL CES-AC-AR-C01-AH-SA-C2296

Fill up the form and we will get back to you in few hours with right details. fill the form to help you better way.