We are EUCHNER STA3A-4141A024M product supplier in India

ORDER NO. 099274

Order number099274
Item designationSTA3A-4141A024M
Gross weight0,646kg
Customs tariff number85365019

Safety switch STA with door monitoring contact

  • Auxiliary release on the front
  • With door monitoring contact

Approach direction

Horizontal and vertical

Can be adjusted in 90° steps

Solenoid operating voltage

  • AC/DC 24 V +10%, -15%

Guard locking type

STA3Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid.

Switching element

4141Slow-action switching contact 2 NC  + 2 NC  (door monitoring contact)

Auxiliary release

This is used for releasing the guard locking with the aid of a tool. To protect against tampering, the auxiliary release is sealed with sealing lacquer.

Electrical connection ratings

Power consumption8 W
Connection cross-section0.34 … 1.5 mm²
Rated insulation voltage Ui250 V
Rated impulse withstand voltage Uimp2.5 kV
Short circuit protection according to IEC 60269-14A gG
Switching current
min. at 24 V1 mA
Switching voltage
min. at 10 mA12 V
Utilization category
AC-154A 230V
DC-134A 24V
Solenoid operating voltage
AC/DC24 V -15% … +10%
Solenoid duty cycle100 %
rated thermal current Ith4 A

Mechanical values and environment

Approach directionA
Approach speedmax. 20 m/min
Number of door position positively driven contacts2
Number of guard lock monitoring positively driven contacts2
Connection
3 xM20 x 1.5
Degree of protectionIP67
Extraction force30 N
Material
ContactSilver alloy, gold flashed
HousingAlloy – die-cast
Actuation frequencymax. 1200 1/h
Actuating force35 N
Mechanical life1 x 10⁶
Installation orientationany
Insertion depth24.5 mm
Switching principleSlow-action switching contact
Retention force20 N
Ambient temperature-20 … +80 °C
Locking force Fmax3000 N
Locking force FZh2300 N
Guard locking principleClosed-circuit current principle

Reliability values acc. to EN ISO 13849-1

Control of guard locking
CategoryDepending on external control of guard locking
Performance LevelDepending on external control of guard locking
PFHDDepending on external control of guard locking
Monitoring of guard locking and the guard position
B10D11.5 x 10⁶

In combination with actuator ACTUATOR-S-GT-SN

Overtravel5 mm
Still not sure what you want?

We are here to help you, send us your details we will assist you to choose right product.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Know the part number Search here
EUCHNER STA4A-2131A024M

EUCHNER STA3A-4141A024M

Fill up the form and we will get back to you in few hours with right details. fill the form to help you better way.