ORDER NO. 088206
Order number | 088206 |
Item designation | TP3-4121A024SR11 |
Gross weight | 0,493kg |
Customs tariff number | 85365019 |
Safety switch TP, plug connector SR11, with door monitoring contact
- Auxiliary release on the front
- With door monitoring contact
- Increased horizontal overtravel
- Plug connector
Approach direction
Horizontal and vertical
Can be adjusted in 90° steps
Increased overtravel for horizontal approach direction
Solenoid operating voltage
- AC/DC 24 V +10%, -15%
Guard locking type
TP3 | Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid. |
Switching element
4121 | Slow-action switching contact 2 NC + 1 NC / 1 NO (door monitoring contact) |
Auxiliary release
This is used for releasing the guard locking with the aid of a tool. To protect against tampering, the auxiliary release is sealed with sealing lacquer.
Electrical connection ratings
Power consumption | 8 W |
Rated insulation voltage Ui | 50 V |
Rated impulse withstand voltage Uimp | 1.5 kV |
Short circuit protection according to IEC 60269-1 | 4A gG |
Switching current | |
min. at 24 V | 1 mA |
Switching voltage | |
min. at 10 mA | 12 V |
Utilization category | |
DC-13 | 4A 24V |
AC-15 | 4A 50V |
Solenoid operating voltage | |
AC/DC | 24 V -15% … +10% |
Solenoid duty cycle | 100 % |
rated thermal current Ith | 4 A |
Mechanical values and environment
Approach speed | max. 20 m/min |
Number of door position NC contacts | 1 |
Number of door position NO contacts | 1 |
Number of guard lock monitoring positively driven contacts | 2 |
Connection | |
1 x | Plug connector SR11 |
Degree of protection | IP65 |
Extraction force | 20 N |
Material | |
Contact | Silver alloy, gold flashed |
Housing | Reinforced thermoplastic |
Actuation frequency | max. 1200 1/h |
Actuating force | 10 N |
Mechanical life | 1 x 10⁶ |
Installation orientation | any |
Switching principle | Slow-action switching contact |
Retention force | 10 N |
Ambient temperature | -20 … +55 °C |
Locking force Fmax | 1300 N |
Locking force FZh | 1000 N |
Guard locking principle | Closed-circuit current principle |
Reliability values acc. to EN ISO 13849-1
Control of guard locking | |
Category | Depending on external control of guard locking |
Performance Level | Depending on external control of guard locking |
PFHD | Depending on external control of guard locking |
Monitoring of guard locking and the guard position | |
B10D | 3 x 10⁶ |
In combination with actuator ACTUATOR-P-GNT
Horizontal overtravel | 7 mm |
In combination with actuator ACTUATOR-P-GT
Horizontal overtravel | 2 mm |
Vertical overtravel | 1.5 mm |