WE HANDLE INQUIRIES THROUGH EMAIL MORE EFFICIENTLY

WE HANDLE INQUIRIES THROUGH EMAIL MORE EFFICIENTLY

Euchner EUCHNER TP4-4141A024SEM4AS1

EUCHNER HBA-113815

EUCHNER TP4-4141A024SEM4AS1

Euchner

TP3-4131A024SR11

We are EUCHNER TP4-4141A024SEM4AS1 product supplier in India

ORDER NO. 088257

Order number088257
Item designationTP4-4141A024SEM4AS1
Gross weight0,47kg
Customs tariff number85365019

Safety switch TP AS1, plug connector M12 (closed-circuit current principle)

  • Auxiliary release on the front
  • Increased horizontal overtravel
  • Optionally without guard lock monitoring

Guard locking types

TP3Closed-circuit current principle, guard locking by spring force. Release by control of AS-i output 0.
TP4Open-circuit current principle, guard locking by control of AS-i output 0. Release by spring force.

Control of the guard locking solenoid

The guard locking solenoid is controlled by the control system via AS-Interface bus bit D0. In addition, the 24V connection can be switched safely.

AS-Interface inputs, version AS1

D0, D1Door monitoring contact SK
D2, D3Solenoid monitoring contact ├ЬK

AS-Interface inputs, version AS1

D0, D1Door monitoring contact SK 1
D2, D3Door monitoring contact SK 2

Evaluation is performed via a safety monitor.

AS-Interface outputs

D0Guard locking solenoid
D1LED red
D2LED green

LED function display

  • The Power LED indicates the operating voltage on the bus.
  • The Fault LED indicates if a fault has been detected on the AS-Interface bus.
  • The green and the red LEDs can be controlled as required by the control system via the bus using bits D1 and D2.

Auxiliary release

This is used for releasing the guard locking with the aid of a tool. To protect against tampering, the auxiliary release is sealed with sealing lacquer.

Electrical connection ratings

ASI data in
according to AS-i Safety at WorkD0, D1, D2, D3 
ASI data out
LED redD1 
ASI slave type
according to ASI specification 2.1ID code: B
ASI operating currentmax. 45 mA
ASI auxiliary voltage
IEC 60742, PELV24 V -15% … +10%
ASI auxiliary current300 mA
ASI voltage22.5 … 30 … 31.6 V
Solenoid duty cycle100 %

Mechanical values and environment

Approach speedmax. 20 m/min
Number of door position positively driven contacts
according to AS-i Safety at Work
Number of guard lock monitoring positively driven contacts
according to AS-i Safety at Work1 D2,D3 
Extraction force20 N
Material
HousingReinforced thermoplastic
Actuation frequencymax. 1200 1/h
Mechanical life1 x 10тБ╢
Installation orientationany
Switching principleSlow-action switching contact
Retention force10 N
Ambient temperature-20 … +55 ┬░C

In combination with actuator ACTUATOR-P-GT

Horizontal insertion depth28 mm
Vertical insertion depth29.5 mm
Horizontal overtravel2 mm
Vertical overtravel1.5 mm

In combination with actuator ACTUATOR-P-GNT

Horizontal insertion depth28 mm
Horizontal overtravel7 mm
Still not sure what you want?

We are here to help you, send us your details we will assist you to choose right product.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Know the part number Search here
TP3-4131A024SR11

EUCHNER TP4-4141A024SEM4AS1

Fill up the form and we will get back to you in few hours with right details. fill the form to help you better way.