Euchner EUCHNER TP4-537A024M

EUCHNER HBA-113815

EUCHNER TP4-537A024M

Euchner

EUCHNER TP1-4131A024M

We are EUCHNER TP4-537A024M product supplier in India

ORDER NO. 084339

Order number084339
Item designationTP4-537A024M
Gross weight0,46kg
Customs tariff number85365019

Safety switch TP with door monitoring contact

  • Auxiliary release on the front
  • With door monitoring contact
  • Increased horizontal overtravel

Approach direction

Horizontal and vertical

Can be adjusted in 90° steps

Increased overtravel for horizontal approach direction

Solenoid operating voltage

  • AC/DC 24 V +10%, -15%

Guard locking type

TP4Open-circuit current principle, guard locking by applying voltage to the guard locking solenoid. Release by spring force.

Switching element

537Slow-action switching contact 1 NC + 1 NC (door monitoring contact)

Auxiliary release

This is used for releasing the guard locking with the aid of a tool. To protect against tampering, the auxiliary release is sealed with sealing lacquer.

Electrical connection ratings

Power consumption8 W
Connection cross-section0.34 … 1.5 mm²
Rated insulation voltage Ui250 V
Rated impulse withstand voltage Uimp2.5 kV
Short circuit protection according to IEC 60269-14A gG
Switching current
min. at 24 V1 mA
Switching voltage
min. at 10 mA12 V
Utilization category
AC-154A 230V
DC-134A 24V
Solenoid operating voltage
AC/DC24 V -15% … +10%
Solenoid duty cycle100 %
rated thermal current Ith4 A

Mechanical values and environment

Approach speedmax. 20 m/min
Number of door position NC contacts1
Number of guard lock monitoring positively driven contacts1
Connection
3 xM20 x 1.5
Degree of protectionIP67
Extraction force20 N
Material
HousingReinforced thermoplastic
ContactSilver alloy, gold flashed
Actuation frequencymax. 1200 1/h
Actuating force10 N
Mechanical life1 x 10⁶
Installation orientationany
Switching principleSlow-action switching contact
Retention force10 N
Ambient temperature-20 … +55 °C
Locking force Fmax1300 N
Locking force FZh1000 N
Guard locking principleOpen-circuit current principle

Reliability values acc. to EN ISO 13849-1

Monitoring of guard locking and the guard position
B10D3 x 10⁶

In combination with actuator ACTUATOR-P-GNT

Horizontal overtravel7 mm

In combination with actuator ACTUATOR-P-GT

Horizontal overtravel2 mm
Vertical overtravel1.5 mm
EUCHNER TP1-4131A024M

EUCHNER TP4-537A024M

Fill up the form and we will get back to you in few hours with right details. fill the form to help you better way.