This is used for releasing the guard locking with the aid of a tool. To protect against tampering, the auxiliary release is sealed with sealing lacquer.
Electrical connection ratings
Power consumption
8 W
Connection cross-section
0.34 … 1.5 mm²
Rated insulation voltage Ui
250 V
Rated impulse withstand voltage Uimp
2.5 kV
Short circuit protection according to IEC 60269-1
4A gG
Switching current
min. at 24 V
1 mA
Switching voltage
min. at 10 mA
12 V
Utilization category
AC-15
4A 230V
DC-13
4A 24V
Solenoid operating voltage
AC/DC
24 V -15% … +10%
Solenoid duty cycle
100 %
rated thermal current Ith
4 A
Mechanical values and environment
Approach speed
max. 20 m/min
Number of door position NC contacts
1
Number of guard lock monitoring positively driven contacts
1
Connection
3 x
M20 x 1.5
Degree of protection
IP67
Extraction force
20 N
Material
Housing
Reinforced thermoplastic
Contact
Silver alloy, gold flashed
Actuation frequency
max. 1200 1/h
Actuating force
10 N
Mechanical life
1 x 10⁶
Installation orientation
any
Switching principle
Slow-action switching contact
Retention force
10 N
Ambient temperature
-20 … +55 °C
Locking force Fmax
1300 N
Locking force FZh
1000 N
Guard locking principle
Open-circuit current principle
Reliability values acc. to EN ISO 13849-1
Monitoring of guard locking and the guard position
B10D
3 x 10⁶
In combination with actuator ACTUATOR-P-GNT
Horizontal overtravel
7 mm
In combination with actuator ACTUATOR-P-GT
Horizontal overtravel
2 mm
Vertical overtravel
1.5 mm
EUCHNER TP4-537A024M
Fill up the form and we will get back to you in few hours with right details. fill the form to help you better way.