Article No. IME2015BFBOA
Inductive sensor
- Long sensing range for use in conveying
- With combined AC/DC output and two-wire technology
- Output function normally open / normally closed programmable
- Robust housing for use in harsh industrial environments
- Large operating voltage range
Product characteristics
Output function | normally open / normally closed; (selectable) |
---|---|
Sensing range [mm] | 15 |
Housing | rectangular |
Dimensions [mm] | 40 x 40 x 120 |
Electrical data
Operating voltage [V] | 20…250 AC/DC |
---|---|
Protection class | II |
Reverse polarity protection | no |
Outputs
Output function | normally open / normally closed; (selectable) |
---|---|
Max. voltage drop switching output DC [V] | 6 |
Max. voltage drop switching output AC [V] | 6.5 |
Minimum load current [mA] | 5 |
Max. leakage current [mA] | 2.5 (250 V AC) / 1.3 (110 V AC) / 0.8 (24 V DC) |
Permanent current rating of switching output AC [mA] | 250; (350 (…50 ┬░C)) |
Permanent current rating of switching output DC [mA] | 100 |
Short-time current rating of switching output [mA] | 2200; (20 ms / 0,5 Hz) |
Switching frequency AC [Hz] | 20 |
Switching frequency DC [Hz] | 55 |
Short-circuit proof | no |
Overload protection | no |
Detection zone
Sensing range [mm] | 15 |
---|---|
Real sensing range Sr [mm] | 15 ┬▒ 10 % |
Operating distance [mm] | 0…12.1 |
Accuracy / deviations
Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.4 / aluminium: 0.3 / copper: 0.2 |
---|---|
Hysteresis [% of Sr] | 1…15 |
Switch point drift [% of Sr] | -10…10 |
Operating conditions
Ambient temperature [┬░C] | -25…80 |
---|---|
Protection | IP 65 |
Tests / approvals
EMC | EN 60947-5-2EN 55011class B |
---|---|
MTTF [years] | 603 |
UL approval | Ta0…40 ┬░CEnclosure typeType 1power supplyHazardous voltageFile number ULE174191 |
Mechanical data
Weight [g] | 188.5 |
---|---|
Housing | rectangular |
Mounting | flush mountable |
Dimensions [mm] | 40 x 40 x 120 |
Materials | PPE |
Displays / operating elements
Display | switching status1 x LED, yellow |
---|
Electrical connection
Required protection | miniature fuse to IEC60127-2 sheet 1; тЙд 2 A; fast acting |
---|
Remarks
Remarks | Recommendation: Check the safe functioning of the unit after a short circuit.5 positions of the active zone possible |
---|---|
Pack quantity | 1 pcs. |
Electrical connection
Connection | terminals: …2.5 mm┬▓; Cable sheath: ├Ш 7…13 mm; Cable gland: M20 X 1.5 |
---|