Article No. IME2015BFBOA
Inductive sensor
- Long sensing range for use in conveying
- With combined AC/DC output and two-wire technology
- Output function normally open / normally closed programmable
- Robust housing for use in harsh industrial environments
- Large operating voltage range
Product characteristics
| Output function | normally open / normally closed; (selectable) |
|---|---|
| Sensing range [mm] | 15 |
| Housing | rectangular |
| Dimensions [mm] | 40 x 40 x 120 |
Electrical data
| Operating voltage [V] | 20…250 AC/DC |
|---|---|
| Protection class | II |
| Reverse polarity protection | no |
Outputs
| Output function | normally open / normally closed; (selectable) |
|---|---|
| Max. voltage drop switching output DC [V] | 6 |
| Max. voltage drop switching output AC [V] | 6.5 |
| Minimum load current [mA] | 5 |
| Max. leakage current [mA] | 2.5 (250 V AC) / 1.3 (110 V AC) / 0.8 (24 V DC) |
| Permanent current rating of switching output AC [mA] | 250; (350 (…50 °C)) |
| Permanent current rating of switching output DC [mA] | 100 |
| Short-time current rating of switching output [mA] | 2200; (20 ms / 0,5 Hz) |
| Switching frequency AC [Hz] | 20 |
| Switching frequency DC [Hz] | 55 |
| Short-circuit proof | no |
| Overload protection | no |
Detection zone
| Sensing range [mm] | 15 |
|---|---|
| Real sensing range Sr [mm] | 15 ± 10 % |
| Operating distance [mm] | 0…12.1 |
Accuracy / deviations
| Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.4 / aluminium: 0.3 / copper: 0.2 |
|---|---|
| Hysteresis [% of Sr] | 1…15 |
| Switch point drift [% of Sr] | -10…10 |
Operating conditions
| Ambient temperature [°C] | -25…80 |
|---|---|
| Protection | IP 65 |
Tests / approvals
| EMC | EN 60947-5-2EN 55011class B |
|---|---|
| MTTF [years] | 603 |
| UL approval | Ta0…40 °CEnclosure typeType 1power supplyHazardous voltageFile number ULE174191 |
Mechanical data
| Weight [g] | 188.5 |
|---|---|
| Housing | rectangular |
| Mounting | flush mountable |
| Dimensions [mm] | 40 x 40 x 120 |
| Materials | PPE |
Displays / operating elements
| Display | switching status1 x LED, yellow |
|---|
Electrical connection
| Required protection | miniature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting |
|---|
Remarks
| Remarks | Recommendation: Check the safe functioning of the unit after a short circuit.5 positions of the active zone possible |
|---|---|
| Pack quantity | 1 pcs. |
Electrical connection
| Connection | terminals: …2.5 mm²; Cable sheath: Ø 7…13 mm; Cable gland: M20 X 1.5 |
|---|