| Product characteristics |
|---|
| Number of inputs and outputs | Number of digital outputs: 4 |
| Factory setting | 2 switching outputs level (OUT1, OUT2); 2 switching outputs temperature (OUT3, OUT4); mineral oils |
| Probe length L [mm] | 472 |
| Application |
|---|
| Media | hydrous coolants; oils; oil-based media; water; media similar to water |
| Dielectric constant of the medium | > 2 |
| Cannot be used for | extremely conductive media; adhering media; granulates; bulk material; acids; alkali |
| Tank pressure [bar] | 0.5; (when mounting with mounting accessories: E43001 – E43007, E43019) |
| Coolants |
|---|
| Medium temperature [°C] | 0…35; (with climatic tube E43101 35…60 °C) |
| Oil |
|---|
| Medium temperature [°C] | 0…70 |
| Medium temperature short time [°C] | 0…90; (< 1 h) |
| Water |
|---|
| Medium temperature [°C] | 0…35; (with climatic tube E43101 35…60 °C) |
| Electrical data |
|---|
| Operating voltage [V] | 18…30 DC |
| Current consumption [mA] | < 50 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time [s] | < 3 |
| Inputs / outputs |
|---|
| Number of inputs and outputs | Number of digital outputs: 4 |
| Outputs |
|---|
| Total number of outputs | 4 |
| Output signal | switching signal; IO-Link |
| Electrical design | PNP/NPN |
| Number of digital outputs | 4 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V] | 2.5 |
| Permanent current rating of switching output DC [mA] | 200 |
| Short-circuit protection | yes |
| Type of short-circuit protection | thermal, pulsed |
| Overload protection | yes |
|