Product characteristics |
---|
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
Measuring range | -0.0124…0.25 bar-12.4…250 mbar-5…100.4 inH2O-1.24…25 kPa |
Process connection | threaded connection G 1 external thread Aseptoflex Vario |
Application |
---|
Special feature | Gold-plated contacts |
Application | flush mountable for the food and beverage industry |
Media | viscous media and liquids with suspended particles; liquids and gases |
Medium temperature [°C] | -25…125; (145 max. 1h) |
Min. bursting pressure | 30000 mbar12044 inH2O3000 kPa |
Pressure rating | 6000 mbar2400 inH2O600 kPa |
Vacuum resistance [mbar] | -1000 |
Type of pressure | relative pressure |
No dead space | yes |
MAWP (for applications according to CRN) [bar] | 10 |
Electrical data |
---|
Min. insulation resistance [MΩ] | 100; (500 V DC) |
Protection class | III |
Reverse polarity protection | yes |
Measuring principle | hydrostatic |
Integrated watchdog | yes |
2-wire |
---|
Operating voltage [V] | 20…32 DC |
Current consumption [mA] | 3.6…21 |
Power-on delay time [s] | 1 |
3-wire |
---|
Operating voltage [V] | 18…32 DC |
Current consumption [mA] | < 45 |
Power-on delay time [s] | 0.5 |
Inputs / outputs |
---|
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
Outputs |
---|
Total number of outputs | 2 |
Output signal | switching signal; analogue signal; IO-Link; (configurable) |
Electrical design | PNP/NPN |
Number of digital outputs | 2 |
Output function | normally open / normally closed; (parameterisable) |
Number of analogue outputs | 1 |
Analogue current output [mA] | 4…20, invertible; (scalable) |
Short-circuit protection | yes |
Type of short-circuit protection | pulsed |
Overload protection | yes |
2-wire |
---|
Max. load [Ω] | 300 |
3-wire |
---|
Max. voltage drop switching output DC [V] | 2 |
Permanent current rating of switching output DC [mA] | 250 |
Switching frequency DC [Hz] | 125 |
Max. load [Ω] | (Ub – 10 V) / 20 mA |
Measuring/setting range |
---|
Measuring range | -0.0124…0.25 bar-12.4…250 mbar-5…100.4 inH2O-1.24…25 kPa |
Set point SP | -12…250 mbar-4.8…100.4 inH2O-1.2…25 kPa |
Reset point rP | -12.4…249.6 mbar-5…100.2 inH2O-1.24…24.96 kPa |
Analogue start point | -12.4…187.4 mbar-5…75.2 inH2O-1.24…18.74 kPa |
Analogue end point | 50…250 mbar20.1…100.4 inH2O5…25 kPa |
In steps of | 0.2 mbar0.1 inH2O0.02 kPa |
Factory setting | SP1 = 62.4 mbarrP1 = 57.4 mbarSP2 = 187.4 mbarrP2 = 182.4 mbarASP = 0.0 mbarAEP = 250.0 mbar |
Accuracy / deviations |
---|
Switch point accuracy [% of the span] | < ± 0,2; (Turn down 1:1) |
Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
Characteristics deviation [% of the span] | < ± 0,2; (Turn down 1:1 , linearity, incl. hysteresis and repeatability , limit value setting to DIN EN IEC 62828-1) |
Linearity deviation [% of the span] | < ± 0,15; (Turn down 1:1) |
Hysteresis deviation [% of the span] | < ± 0,15; (Turn down 1:1) |
Long-term stability [% of the span] | < ± 0,1; (Turn down 1:1; per year) |
Temperature coefficient zero point [% of the span / 10 K] | < ± 0,05; (0…70 °C) |
Temperature coefficient span [% of the span / 10 K] | < ± 0,15; (0…70 °C) |
Response times |
---|
Damping process value dAP [s] | 0…30 |
Damping for the analogue output dAA [s] | 0.01…99.99 |
2-wire |
---|
Step response time analogue output [ms] | 45 |
3-wire |
---|
Min. response time of switching output (dAP) [ms] | 3 |
Step response time analogue output [ms] | 7 |
Interfaces |
---|
Communication interface | IO-Link |
Transmission type | COM2 (38,4 kBaud) |
IO-Link revision | 1.0 |
Profiles | no profile |
SIO mode | yes |
Required master port type | A |
Process data analogue | 1 |
Process data binary | 2 |
Min. process cycle time [ms] | 2.3 |
Supported DeviceIDs | Type of operationDeviceIDDefault257 |
Operating conditions |
---|
Ambient temperature [°C] | -25…80 |
Storage temperature [°C] | -40…100 |
Protection | IP 67; IP 68; IP 69K |
Tests / approvals |
---|
EMC | EN 61000-4-2 ESD4 kV CD / 8 kV ADEN 61000-4-3 HF radiated10 V/mEN 61000-4-4 Burst2 kVEN 61000-4-5 Surge0,5/1 kVEN 61000-4-6 HF conducted10 V |
Shock resistance | DIN IEC 68-2-2750 g (11 ms) |
Vibration resistance | DIN IEC 68-2-620 g (10…2000 Hz) |
MTTF [years] | 160 |
Note on approval | factory certificate available as download at www.factory-certificate.ifm |
UL approval | UL Approval no.J018File number ULE174189 |
Mechanical data |
---|
Weight [g] | 354 |
Materials | stainless steel (1.4404 / 316L); FKM; PTFE; PBT; PEI; PFA |
Materials (wetted parts) | ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4; PTFE |
Min. pressure cycles | 100 million |
Process connection | threaded connection G 1 external thread Aseptoflex Vario |
Displays / operating elements |
---|
Display | Display unitLED, greenswitching statusLED, yellowfunction displayalphanumeric display, 4-digitmeasured valuesalphanumeric display, 4-digit |
Display unit | mbar; kPa; inH2O; mmWS; % of the span |
Remarks |
---|
Pack quantity | 1 pcs. |
Electrical connection |
---|
Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated |