PN-250-SEN14-MFRKG/US/ /V – Pressure sensor with display

  • Two switching outputs, one of them programmable as IO-Link and one as analogue output
  • Red/green display for clear identification of the acceptable range
  • The process connection can be rotated for optimum alignment
  • With long-term stability thanks to high overload protection
  • Robust design for use in harsh industrial environments
Product characteristics
Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Measuring range0…250 bar0…3625 psi0…25 MPa
Process connectionthreaded connection 1/4″ NPT internal thread
Application
Special featureGold-plated contacts
Measuring elementmetallic thin film cell
Applicationfor industrial applications
Medialiquids and gases
Medium temperature [°C]-25…80
Min. bursting pressure1200 bar17400 psi120 MPa
Pressure rating500 bar7250 psi50 Mpa
Vacuum resistance [mbar]-1000
Type of pressurerelative pressure
MAWP (for applications according to CRN)500 bar7250 psi50 MPa
Electrical data
Operating voltage [V]18…30 DC; (to SELV/PELV)
Current consumption [mA]< 35
Min. insulation resistance [MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]0.3
Integrated watchdogyes
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs2
Output signalswitching signal; analogue signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]2
Permanent current rating of switching output DC [mA]250
Switching frequency DC [Hz]< 500
Number of analogue outputs1
Analogue current output [mA]4…20; (scalable 1:5)
Max. load [Ω]500
Analogue voltage output [V]0…10; (scalable 1:5)
Min. load resistance [Ω]2000
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Measuring/setting range
Measuring range0…250 bar0…3625 psi0…25 MPa
Analogue start point0…200 bar0…2900 psi0…20 MPa
Analogue end point50…250 bar725…3625 psi5…25 MPa
Factory setting / CMPT = 2
Set point SP1.5…250 bar25…3625 psi0.15…25 MPa
Reset point rP0.5…249 bar10…3610 psi0.05…24.9 MPa
Min. difference between SP and rP1.5 bar15 psi0.15 MPa
In steps of0.5 bar5 psi0.05 MPa
Status_B High Resolution / CMPT = 3
Set point SP1.6…250 bar23…3626 psi0.16…25 MPa
Reset point rP0.5…249 bar8…3611 psi0.05…24.9 MPa
Min. difference between SP and rP1.1 bar15 psi0.11 MPa
In steps of0.1 bar1 psi0.01 MPa
Accuracy / deviations
Notes on the accuracy / deviationswitch point accuracy, linearity error under DNV GL: < ± 1%: < ± 1%
Switch point accuracy [% of the span]< ± 0,4; (Turn down 1:1)
Repeatability [% of the span]< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation [% of the span]< ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation [% of the span]< ± 0,1; (Turn down 1:1)
Long-term stability [% of the span]< ± 0,05; (Turn down 1:1; per 6 months)
Temperature coefficient zero point [% of the span / 10 K]0,2; (-25…80 °C)
Temperature coefficient span [% of the span / 10 K]0,2; (-25…80 °C)
Response times
Response time [ms]< 1.5
Delay time programmable dS, dr [s]0…50
Damping process value dAP [s]0…4
Damping for the analogue output dAA [s]0…4
Max. response time analogue output [ms]3
Software / programming
Parameter setting optionshysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output
Interfaces
Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
SIO modeyes
Required master port typeA; (wenn PIN 2 nicht verbunden: B)
Supported DeviceIDsType of operationDeviceIDFactory setting / CMPT = 2470Status_B High Resolution / CMPT = 3986
NoteFor further information please see the IODD PDF file under “Downloads”
Factory setting / CMPT = 2
ProfilesSmart Sensor: Process Data Variable; Device Identification, Device Diagnosis
Min. process cycle time [ms]2.3
IO-Link resolution pressure [bar]0.1
IO-Link process data (cyclical)functionbit lengthpressure14binary switching information2
IO-Link functions (acyclical)application specific tag
Status_B High Resolution / CMPT = 3
ProfilesSmart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000)
Min. process cycle time [ms]3
IO-Link resolution pressure [bar]0.1
IO-Link process data (cyclical)functionbit lengthpressure16device status4binary switching information2
IO-Link functions (acyclical)application specific tag
Operating conditions
Ambient temperature [°C]-25…80
Storage temperature [°C]-40…100
ProtectionIP 65; IP 67
Tests / approvals
EMCDIN EN 61000-6-2DIN EN 61000-6-3
Shock resistanceDIN EN 60068-2-2750 g (11 ms)
Vibration resistanceDIN EN 60068-2-620 g (10…2000 Hz)
MTTF [years]124
UL approvalUL Approval no.J014
Pressure Equipment DirectiveSound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Mechanical data
Weight [g]219.5
Materials1.4542 (17-4 PH / 630); stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC
Materials (wetted parts)1.4542 (17-4 PH / 630)
Min. pressure cycles100 million
Tightening torque [Nm]> 50; (depends on lubrication, seal and pressure rating)
Process connectionthreaded connection 1/4″ NPT internal thread
Restrictor element integratedno (can be retrofitted)
Displays / operating elements
DisplayDisplay unit3 x LED, green (bar, psi, MPa)switching status2 x LED, yellowmeasured valuesalphanumeric display, red/green 4-digit
Remarks
Pack quantity1 pcs.
Electrical connection
ConnectionConnector: 1 x M12; coding: A; Contacts: gold-plated
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PN2271-01 — 21.02.2020
Still not sure what you want?

We are here to help you, send us your details we will assist you to choose right product.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Know the part number Search here

IFM PN2271

Fill up the form and we will get back to you in few hours with right details. fill the form to help you better way.