IFM IFM PN2299

ifm distributor in India

IFM PN2299

IFM

We are IFM Product supplier in India

PN-1-1BREN14-MFRKG/US/ /V – Pressure sensor with display

  • Two switching outputs, one of them programmable as IO-Link and one as analogue output
  • Red/green display for clear identification of the acceptable range
  • The process connection can be rotated for optimum alignment
  • With long-term stability thanks to high overload protection
  • Robust design for use in harsh industrial environments
Product characteristics
Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Measuring range-1…1 bar-1000…1000 mbar-14.5…14.5 psi-29.5…29.5 inHg-402…402 inH2O-100…100 kPa
Process connectionthreaded connection 1/4″ NPT internal thread
Application
Special featureGold-plated contacts
Measuring elementceramic-capacitive pressure measuring cell
Applicationfor industrial applications
Medialiquids and gases
Medium temperature [°C]-25…80
Min. bursting pressure30000 mbar450 psi3000 kPa
Pressure rating10000 mbar145 psi1000 kPa
Vacuum resistance [mbar]-1000
Type of pressurerelative pressure; vacuum
MAWP (for applications according to CRN)20 bar20000 mbar290 psi2000 kPa
Electrical data
Operating voltage [V]18…30 DC; (to SELV/PELV)
Current consumption [mA]< 35
Min. insulation resistance [MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]0.3
Integrated watchdogyes
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs2
Output signalswitching signal; analogue signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]2
Permanent current rating of switching output DC [mA]250
Switching frequency DC [Hz]< 500
Number of analogue outputs1
Analogue current output [mA]4…20; (scalable 1:5)
Max. load [Ω]500
Analogue voltage output [V]0…10; (scalable 1:5)
Min. load resistance [Ω]2000
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Measuring/setting range
Measuring range-1…1 bar-1000…1000 mbar-14.5…14.5 psi-29.5…29.5 inHg-402…402 inH2O-100…100 kPa
Analogue start point-1000…600 mbar-14.5…8.7 psi-29.5…17.7 inHg-402…240 inH2O-100…60 kPa
Analogue end point-600…1000 mbar-8.7…14.5 psi-17.7…29.5 inHg-240…402 inH2O-60…100 kPa
Factory setting / CMPT = 2
Set point SP-985…1000 mbar-14.3…14.5 psi-29.2…29.5 inHg-396…402 inH2O-98.5…100 kPa
Reset point rP-995…990 mbar-14.45…14.4 psi-29.4…29.3 inHg-400…398 inH2O-99.5…99 kPa
Min. difference between SP and rP10 mbar0.15 psi0.3 inHg4 inH2O1 kPa
In steps of5 mbar0.05 psi0.1 inHg2 inH2O0.5 kPa
Status_B High Resolution / CMPT = 3
Set point SP-987…1000 mbar-14.32…14.5 psi-29.2…29.5 inHg-396…401 inH2O-98.7…100 kPa
Reset point rP-996…992 mbar-14.44…14.38 psi-29.4…29.3 inHg-400…398 inH2O-99.6…99.2 kPa
Min. difference between SP and rP9 mbar0.12 psi0.3 inHg4 inH2O0.9 kPa
In steps of1 mbar0.01 psi0.1 inHg1 inH2O0.1 kPa
Accuracy / deviations
Switch point accuracy [% of the span]< ± 0,4; (Turn down 1:1)
Repeatability [% of the span]< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation [% of the span]< ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation [% of the span]< ± 0,1; (Turn down 1:1)
Long-term stability [% of the span]< ± 0,05; (Turn down 1:1; per 6 months)
Temperature coefficient zero point [% of the span / 10 K]< ± 0,2; (-0…80 °C)
Temperature coefficient span [% of the span / 10 K]< ± 0,2; (-0…80 °C)
Notes on the accuracy / deviationswitch point accuracy, linearity error under DNV GL: < ± 1%: < ± 1%
Response times
Response time [ms]< 1.5
Delay time programmable dS, dr [s]0…50
Damping process value dAP [s]0…4
Damping for the analogue output dAA [s]0…4
Max. response time analogue output [ms]3
Software / programming
Parameter setting optionshysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output
Interfaces
Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
SIO modeyes
Required master port typeA; (wenn PIN 2 nicht verbunden: B)
Supported DeviceIDsType of operationDeviceIDFactory setting / CMPT = 2477Status_B High Resolution / CMPT = 3993
NoteFor further information please see the IODD PDF file under “Downloads”
Factory setting / CMPT = 2
ProfilesSmart Sensor: Process Data Variable; Device Identification, Device Diagnosis
Min. process cycle time [ms]2.3
IO-Link resolution pressure [mbar]1
IO-Link process data (cyclical)functionbit lengthpressure14binary switching information2
IO-Link functions (acyclical)application specific tag
Status_B High Resolution / CMPT = 3
ProfilesSmart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000)
Min. process cycle time [ms]3
IO-Link resolution pressure [mbar]1
IO-Link process data (cyclical)functionbit lengthpressure16device status4binary switching information2
IO-Link functions (acyclical)application specific tag
Operating conditions
Ambient temperature [°C]-25…80
Storage temperature [°C]-40…100
ProtectionIP 65; IP 67
Tests / approvals
EMCDIN EN 61000-6-2DIN EN 61000-6-3
Shock resistanceDIN EN 60068-2-2750 g (11 ms)
Vibration resistanceDIN EN 60068-2-620 g (10…2000 Hz)
MTTF [years]138
UL approvalUL Approval no.J012
Pressure Equipment DirectiveSound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Mechanical data
Weight [g]223.5
Materialsstainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC
Materials (wetted parts)stainless steel (1.4404 / 316L); AI2O3 (96%; ceramics); FKM
Min. pressure cycles100 million
Tightening torque [Nm]> 50; (depends on lubrication, seal and pressure rating)
Process connectionthreaded connection 1/4″ NPT internal thread
Restrictor element integratedno (can be retrofitted)
Displays / operating elements
DisplayDisplay unit5 x LED, green (mbar, psi, kPa, inH2O, inHg)switching status2 x LED, yellowmeasured valuesalphanumeric display, red/green 4-digit
Remarks
Pack quantity1 pcs.
Electrical connection
ConnectionConnector: 1 x M12; coding: A; Contacts: gold-plated
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PN2299-01 — 21.02.2020