IFM IFM PN2299

ifm distributor in India

IFM PN2299

IFM

We are IFM Product supplier in India

PN-1-1BREN14-MFRKG/US/ /V – Pressure sensor with display

  • Two switching outputs, one of them programmable as IO-Link and one as analogue output
  • Red/green display for clear identification of the acceptable range
  • The process connection can be rotated for optimum alignment
  • With long-term stability thanks to high overload protection
  • Robust design for use in harsh industrial environments
Product characteristics
Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Measuring range-1…1 bar-1000…1000 mbar-14.5…14.5 psi-29.5…29.5 inHg-402…402 inH2O-100…100 kPa
Process connectionthreaded connection 1/4″ NPT internal thread
Application
Special featureGold-plated contacts
Measuring elementceramic-capacitive pressure measuring cell
Applicationfor industrial applications
Medialiquids and gases
Medium temperature [°C]-25…80
Min. bursting pressure30000 mbar450 psi3000 kPa
Pressure rating10000 mbar145 psi1000 kPa
Vacuum resistance [mbar]-1000
Type of pressurerelative pressure; vacuum
MAWP (for applications according to CRN)20 bar20000 mbar290 psi2000 kPa
Electrical data
Operating voltage [V]18…30 DC; (to SELV/PELV)
Current consumption [mA]< 35
Min. insulation resistance [MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]0.3
Integrated watchdogyes
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs2
Output signalswitching signal; analogue signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]2
Permanent current rating of switching output DC [mA]250
Switching frequency DC [Hz]< 500
Number of analogue outputs1
Analogue current output [mA]4…20; (scalable 1:5)
Max. load [Ω]500
Analogue voltage output [V]0…10; (scalable 1:5)
Min. load resistance [Ω]2000
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Measuring/setting range
Measuring range-1…1 bar-1000…1000 mbar-14.5…14.5 psi-29.5…29.5 inHg-402…402 inH2O-100…100 kPa
Analogue start point-1000…600 mbar-14.5…8.7 psi-29.5…17.7 inHg-402…240 inH2O-100…60 kPa
Analogue end point-600…1000 mbar-8.7…14.5 psi-17.7…29.5 inHg-240…402 inH2O-60…100 kPa
Factory setting / CMPT = 2
Set point SP-985…1000 mbar-14.3…14.5 psi-29.2…29.5 inHg-396…402 inH2O-98.5…100 kPa
Reset point rP-995…990 mbar-14.45…14.4 psi-29.4…29.3 inHg-400…398 inH2O-99.5…99 kPa
Min. difference between SP and rP10 mbar0.15 psi0.3 inHg4 inH2O1 kPa
In steps of5 mbar0.05 psi0.1 inHg2 inH2O0.5 kPa
Status_B High Resolution / CMPT = 3
Set point SP-987…1000 mbar-14.32…14.5 psi-29.2…29.5 inHg-396…401 inH2O-98.7…100 kPa
Reset point rP-996…992 mbar-14.44…14.38 psi-29.4…29.3 inHg-400…398 inH2O-99.6…99.2 kPa
Min. difference between SP and rP9 mbar0.12 psi0.3 inHg4 inH2O0.9 kPa
In steps of1 mbar0.01 psi0.1 inHg1 inH2O0.1 kPa
Accuracy / deviations
Switch point accuracy [% of the span]< ± 0,4; (Turn down 1:1)
Repeatability [% of the span]< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation [% of the span]< ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation [% of the span]< ± 0,1; (Turn down 1:1)
Long-term stability [% of the span]< ± 0,05; (Turn down 1:1; per 6 months)
Temperature coefficient zero point [% of the span / 10 K]< ± 0,2; (-0…80 °C)
Temperature coefficient span [% of the span / 10 K]< ± 0,2; (-0…80 °C)
Notes on the accuracy / deviationswitch point accuracy, linearity error under DNV GL: < ± 1%: < ± 1%
Response times
Response time [ms]< 1.5
Delay time programmable dS, dr [s]0…50
Damping process value dAP [s]0…4
Damping for the analogue output dAA [s]0…4
Max. response time analogue output [ms]3
Software / programming
Parameter setting optionshysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output
Interfaces
Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
SIO modeyes
Required master port typeA; (wenn PIN 2 nicht verbunden: B)
Supported DeviceIDsType of operationDeviceIDFactory setting / CMPT = 2477Status_B High Resolution / CMPT = 3993
NoteFor further information please see the IODD PDF file under “Downloads”
Factory setting / CMPT = 2
ProfilesSmart Sensor: Process Data Variable; Device Identification, Device Diagnosis
Min. process cycle time [ms]2.3
IO-Link resolution pressure [mbar]1
IO-Link process data (cyclical)functionbit lengthpressure14binary switching information2
IO-Link functions (acyclical)application specific tag
Status_B High Resolution / CMPT = 3
ProfilesSmart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000)
Min. process cycle time [ms]3
IO-Link resolution pressure [mbar]1
IO-Link process data (cyclical)functionbit lengthpressure16device status4binary switching information2
IO-Link functions (acyclical)application specific tag
Operating conditions
Ambient temperature [°C]-25…80
Storage temperature [°C]-40…100
ProtectionIP 65; IP 67
Tests / approvals
EMCDIN EN 61000-6-2DIN EN 61000-6-3
Shock resistanceDIN EN 60068-2-2750 g (11 ms)
Vibration resistanceDIN EN 60068-2-620 g (10…2000 Hz)
MTTF [years]138
UL approvalUL Approval no.J012
Pressure Equipment DirectiveSound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Mechanical data
Weight [g]223.5
Materialsstainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC
Materials (wetted parts)stainless steel (1.4404 / 316L); AI2O3 (96%; ceramics); FKM
Min. pressure cycles100 million
Tightening torque [Nm]> 50; (depends on lubrication, seal and pressure rating)
Process connectionthreaded connection 1/4″ NPT internal thread
Restrictor element integratedno (can be retrofitted)
Displays / operating elements
DisplayDisplay unit5 x LED, green (mbar, psi, kPa, inH2O, inHg)switching status2 x LED, yellowmeasured valuesalphanumeric display, red/green 4-digit
Remarks
Pack quantity1 pcs.
Electrical connection
ConnectionConnector: 1 x M12; coding: A; Contacts: gold-plated
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PN2299-01 — 21.02.2020
Still not sure what you want?

We are here to help you, send us your details we will assist you to choose right product.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Know the part number Search here

IFM PN2299

Fill up the form and we will get back to you in few hours with right details. fill the form to help you better way.