| Product characteristics |
|---|
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
| Process connection | threaded connection M18 x 1,5 internal thread |
| Application |
|---|
| Special feature | Gold-plated contacts |
| Media | water; glycol solutions; air; oils |
| Note on media | low-viscosity oils with viscosity: ≤ 40 mm²/s (40 °C)high-viscosity oils with viscosity: > 40 mm²/s (40 °C) |
| Medium temperature [°C] | -20…90 |
| Pressure rating [bar] | 100 |
| Pressure rating [Mpa] | 10 |
| MAWP (for applications according to CRN) [bar] | 100 |
| Electrical data |
|---|
| Operating voltage [V] | 18…30 DC |
| Current consumption [mA] | < 100 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time [s] | 10 |
| Inputs / outputs |
|---|
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
| Outputs |
|---|
| Total number of outputs | 2 |
| Output signal | switching signal; analogue signal; frequency signal; IO-Link; (configurable) |
| Electrical design | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V] | 2.5 |
| Permanent current rating of switching output DC [mA] | 250 |
| Number of analogue outputs | 1 |
| Analogue current output [mA] | 4…20; (scalable) |
| Max. load [Ω] | 350 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
| Frequency of the output [Hz] | 0…1000 |
| Measuring/setting range |
|---|
| Probe length L [mm] | 45 |
| Operating mode | relative; absolutely liquid; absolutely gaseous; (absolute: reference measurement recommended) |
| Note on factory setting | Operating mode: relative |
| Temperature monitoring |
|---|
| Measuring range [°C] | -20…90 |
| Resolution [°C] | 0.2 |
| Liquid media – absolute operating mode |
|---|
| Setting range [m/s] | 0.04…3 |
| Greatest sensitivity [m/s] | 0.04…3 |
| Liquid media – relative operating mode |
|---|
| Setting range [m/s] | 0.04…6 |
| Greatest sensitivity [m/s] | 0.04…3 |
| Gases – operating mode “absolute” |
|---|
| Setting range [m/s] | 0…100 |
| Greatest sensitivity [m/s] | 30…100 |
| Gases – operating mode “relative” |
|---|
| Setting range [m/s] | 0…200 |
| Greatest sensitivity [m/s] | 30…100 |
| Accuracy / deviations |
|---|
| Temperature drift [cm/s x 1/K] | 0,003 m/s x 1/K (< 20 °C; > 70 °C) |
| Temperature gradient [K/min] | 100 |
| Absolute operating mode |
|---|
| Repeatability | 0,05 m/s; (water; flow velocity: 0,05…3 m/s) |
| Relative operating mode |
|---|
| Accuracy | ± (7 % MW + 2 % MEW); (for relative mode in the range of maximum sensitivity under the following conditions:; water: 20…70 °C; inlet length: 1.5 m; DN25 (DIN 2448); mounting position according to instructions; Accuracy can differ for other media and mounting positions.) |
| Repeatability | 0,05 m/s; (water; flow velocity: 0,05…3 m/s) |
| Temperature monitoring |
|---|
| Temperature drift | ± 0,005 K/°C |
| Accuracy [K] | ± 0,3 / ± 1; (water; flow velocity: 0,3…3 m/s / air; flow velocity: > 10 m/s) |
| Response times |
|---|
| Response time [s] | 0.5; (T09; water; glycol: 0,8 s; air: 7 s; oil: 1,8 s; each T09) |
| Temperature monitoring |
|---|
| Dynamic response T05 / T09 [s] | 1,5 (T09); (water; flow velocity: 0,3…3 m/s) |
| Software / programming |
|---|
| Parameter setting options | hysteresis / window; normally open / normally closed; switching logic; current/frequency output; medium selection; Damping; Teach function; display can be rotated and switched off; standard unit of measurement; process value colour |
| Interfaces |
|---|
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 2 |
| Process data binary | 2 |
| Min. process cycle time [ms] | 3 |
| Supported DeviceIDs | Type of operationDeviceIDFactory setting / ModE = (REL)533ModE = (LIQU)540ModE = (GAS)547 |
| Operating conditions |
|---|
| Ambient temperature [°C] | -40…80 |
| Storage temperature [°C] | -40…100 |
| Protection | IP 65; IP 67 |
| Tests / approvals |
|---|
| EMC | DIN EN 60947-5-9 |
| Shock resistance | DIN EN 60068-2-2750 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-620 g (10…2000 Hz) |
| MTTF [years] | 132 |
| UL approval | UL Approval no.I003 |
| Mechanical data |
|---|
| Weight [g] | 314 |
| Materials | stainless steel (1.4404 / 316L); stainless steel (1.4310 / 301); PBT-GF20; PBT-GF30 |
| Materials (wetted parts) | stainless steel (1.4404 / 316L); Gasket: FKM |
| Process connection | threaded connection M18 x 1,5 internal thread |
| Displays / operating elements |
|---|
| Display | Display unit6 x LED, green (%, m/s, l/min, m³/h, °C, 10³)switching status2 x LED, yellowmeasured valuesalphanumeric display, red/green 4-digit |
| Remarks |
|---|
| Remarks | MW = measured valueMEW = Final value of the measuring range |
| Pack quantity | 1 pcs. |
| Electrical connection |
|---|
| Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated |