Product characteristics |
---|
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
Measuring range | 10…1250 l/min0.3…103.6 m/s0.2…75 m³/h |
Process connection | threaded connection G 1/2 DN15 |
Application |
---|
Application | for industrial applications |
Media | compressed air |
Medium temperature [°C] | 0…60 |
Pressure rating [bar] | 16 |
Pressure rating [Mpa] | 1.6 |
Electrical data |
---|
Operating voltage [V] | 18…30 DC; (to SELV/PELV) |
Current consumption [mA] | < 110 |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | 1 |
Inputs / outputs |
---|
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
Outputs |
---|
Total number of outputs | 2 |
Output signal | switching signal; analogue signal; pulse signal; IO-Link; (configurable) |
Electrical design | PNP |
Number of digital outputs | 2 |
Output function | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] | 2 |
Permanent current rating of switching output DC [mA] | 250; (per output) |
Number of analogue outputs | 1 |
Analogue current output [mA] | 4…20; (scalable) |
Max. load [Ω] | 500 |
Pulse output | consumed quantity meter |
Short-circuit protection | yes |
Type of short-circuit protection | pulsed |
Overload protection | yes |
Measuring/setting range |
---|
Measuring range | 10…1250 l/min0.3…103.6 m/s0.2…75 m³/h |
Display range | 0…1500 l/min0…124.3 m/s0…90 m³/h |
Set point SP | 10…1250 l/min0.8…103.6 m/s0.6…75 m³/h |
Reset point rP | 4…1244 l/min0.3…103.1 m/s0.2…74.6 m³/h |
Analogue start point ASP | 0…938 l/min0…77.7 m/s0…56.3 m³/h |
Analogue end point AEP | 312…1250 l/min25.9…103.6 m/s18.7…75 m³/h |
In steps of | 1 l/min0.1 m/s0.1 m³/h |
Volumetric flow quantity monitoring |
---|
Pulse value | 0.001…1000000 m³ |
In steps of | 0.001 m³ |
Pulse length [s] | 0,02…2 |
Temperature monitoring |
---|
Measuring range [°C] | 0…60 |
Display range [°C] | -12…72 |
Accuracy / deviations |
---|
Flow monitoring |
---|
Repeatability [% of the measured value] | ± 1,5 |
Accuracy (in the measuring range) | ± (15 % MW + 1,5 % MEW); (maximum value to be achieved for air quality class 344 (DIN 8573-1); when using pipes of tolerance class T3/T4; inlet and outlet pipe lengths without edges and abrupt diameter changes; inner surface of the pipe free of burrs) |
Temperature monitoring |
---|
Accuracy [K] | ± 2; (medium flow in the limit area of the flow measurement range) |
Response times |
---|
Flow monitoring |
---|
Response time [s] | 0.1; (dAP = 0) |
Damping process value dAP in steps [s] | 0 – 0,2 – 0,4 – 0,6 – 0,8 – 1 |
Software / programming |
---|
Parameter setting options | Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; totaliser |
Interfaces |
---|
Communication interface | IO-Link |
Transmission type | COM2 (38,4 kBaud) |
IO-Link revision | 1.1 |
SDCI standard | IEC 61131-9 CDV |
Profiles | no profile |
SIO mode | yes |
Required master port type | A |
Process data analogue | 3 |
Process data binary | 2 |
Min. process cycle time [ms] | 4.1 |
Supported DeviceIDs | Type of operationDeviceIDDefault262 |
Operating conditions |
---|
Ambient temperature [°C] | 0…60 |
Storage temperature [°C] | -20…85 |
Max. relative air humidity [%] | 90 |
Protection | IP 65 |
Tests / approvals |
---|
EMC | DIN EN 61000-6-2DIN EN 61000-6-3 |
CPA approval | model number004TGaccuracy class-maximum allowable error± 16,5 % FSQ (min)0,2 m³/hQ (t)-Q (max)75 m³/h |
Vibration resistance | DIN EN 68000-2-65 g (55…2000 Hz) |
MTTF [years] | 227 |
Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data |
---|
Weight [g] | 579 |
Materials | PBT-GF20; NBR; PC; stainless steel (1.4301 / 304); PTFE; brass coated; FKM; aluminium powder-coated |
Materials (wetted parts) | stainless steel (1.4301 / 304); FKM; ceramics glass passivated; PEEK GF30; polyester; aluminium |
Tightening torque [Nm] | 50 |
Process connection | threaded connection G 1/2 DN15 |
Displays / operating elements |
---|
Display | Display unit5 x LED, green (Nl/min, Nm³/h, Nm/s, Nm³, °C)function display1 x LED, greenswitching status2 x LED, yellowmeasured valuesalphanumeric display, 4-digitprogrammingalphanumeric display, 4-digit |
Remarks |
---|
Remarks | MW = measured valueMEW = Final value of the measuring rangeMeasuring, display and setting ranges refer to the standard volume flow according to DIN ISO 2533.For information about installation and operation please see the operating instructions. |
Pack quantity | 1 pcs. |
Electrical connection |
---|
Connection | Connector: 1 x M12; coding: A |