Article No. SMR11GGXFRKG/US-100
Magnetic-inductive flow meter
- Precise measurement of flow, consumption and medium temperature
- High accuracy, repeatability and measurement dynamics
- With switching output, analogue output and pulse output
- Clearly visible 4-digit LED display
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
|---|---|
| Measuring range | 0.2…100 l/min0.01…6 m³/h |
| Process connection | threaded connection G 1 DN25 flat seal |
Application
| Special feature | Gold-plated contacts |
|---|---|
| Application | totaliser function; for industrial applications |
| Installation | connection to pipe by means of an adapter |
| Media | conductive liquids; water; hydrous media |
| Note on media | conductivity: ≥ 20 µS/cmviscosity: < 70 mm²/s (40 °C) |
| Medium temperature [°C] | -10…70 |
| Pressure rating [bar] | 16 |
| Pressure rating [Mpa] | 1.6 |
| MAWP (for applications according to CRN) [bar] | 11.2 |
Electrical data
| Operating voltage [V] | 18…30 DC; (to SELV/PELV) |
|---|---|
| Current consumption [mA] | 95; (24 V) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time [s] | 5 |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
|---|
Inputs
| Inputs | counter reset |
|---|
Outputs
| Total number of outputs | 2 |
|---|---|
| Output signal | switching signal; analogue signal; pulse signal; IO-Link; (configurable) |
| Electrical design | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V] | 2 |
| Permanent current rating of switching output DC [mA] | 200 |
| Number of analogue outputs | 1 |
| Analogue current output [mA] | 4…20; (scalable) |
| Max. load [Ω] | 500 |
| Analogue voltage output [V] | 0…10; (scalable) |
| Min. load resistance [Ω] | 2000 |
| Pulse output | flow rate meter |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Measuring range | 0.2…100 l/min0.01…6 m³/h |
|---|---|
| Display range | -120…120 l/min-7.2…7.2 m³/h |
| Resolution | 0.1 l/min0.005 m³/h |
| Set point SP | 0.7…100 l/min0.04…6 m³/h |
| Reset point rP | 0.2…99.5 l/min0.01…5.97 m³/h |
| Analogue start point ASP | 0…80 l/min0…4.8 m³/h |
| Analogue end point AEP | 20…100 l/min1.2…6 m³/h |
| In steps of | 0.1 l/min0.005 m³/h |
Volumetric flow quantity monitoring
| Pulse value | 0.00001…100 000 m³ |
|---|---|
| Pulse length [s] | 0,0025…2 |
Temperature monitoring
| Measuring range [°C] | -20…80 |
|---|---|
| Resolution [°C] | 0.2 |
| Set point SP [°C] | -19.2…80 |
| Reset point rP [°C] | -19.6…79.6 |
| Analogue start point [°C] | -20…60 |
| Analogue end point [°C] | 0…80 |
| In steps of [°C] | 0.2 |
Accuracy / deviations
Flow monitoring
| Accuracy (in the measuring range) | ± (0,8 % MW + 0,5 % MEW) |
|---|---|
| Repeatability | ± 0,2% MEW |
Temperature monitoring
| Accuracy [K] | ± 2,5 (Q > 5 l/min) |
|---|
Response times
Flow monitoring
| Response time [s] | 0.15; (dAP = 0, T19) |
|---|---|
| Delay time programmable dS, dr [s] | 0…50 |
| Damping process value dAP [s] | 0…5 |
Temperature monitoring
| Dynamic response T05 / T09 [s] | T09 = 20 (Q > 5 l/min) |
|---|
Software / programming
| Parameter setting options | Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/pulse output; start-up delay; display can be deactivated; Display unit |
|---|
Interfaces
| Communication interface | IO-Link |
|---|---|
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 3 |
| Process data binary | 2 |
| Min. process cycle time [ms] | 5 |
| Supported DeviceIDs | Type of operationDeviceIDDefault575 |
Operating conditions
| Ambient temperature [°C] | -10…60 |
|---|---|
| Storage temperature [°C] | -25…80 |
| Protection | IP 67 |
Tests / approvals
| EMC | DIN EN 60947-5-9 |
|---|---|
| CPA approval | model number002MIaccuracy class-maximum allowable error± 1,5 % FSQ (min)0,01 m³/hQ (t)-Q (max)6 m³/h |
| Shock resistance | DIN IEC 68-2-2720 g (11 ms) |
| Vibration resistance | DIN IEC 68-2-65 g (10…2000 Hz) |
| MTTF [years] | 145 |
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
| Weight [g] | 577 |
|---|---|
| Materials | stainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE |
| Materials (wetted parts) | stainless steel (1.4404 / 316L); PEEK; FKM |
| Process connection | threaded connection G 1 DN25 flat seal |
Displays / operating elements
| Display | Display unit6 x LED, green (l/min, m³/h, l, m³, 10³, °C)switching status2 x LED, yellowmeasured valuesalphanumeric display, 4-digitprogrammingalphanumeric display, 4-digit |
|---|
Remarks
| Remarks | MW = measured valueMEW = Final value of the measuring range |
|---|---|
| Pack quantity | 1 pcs. |
Electrical connection
| Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated |
|---|