| Product characteristics |
|---|
| Number of inputs and outputs | Number of digital outputs: 2 |
| Measuring range | -20…140 °C-4…284 °F |
| Process connection | threaded connection G 1/4 |
| Installation length EL [mm] | 50 |
| Application |
|---|
| Special feature | Gold-plated contacts |
| Measuring element | 1 x Pt 1000; (to DIN EN 60751, class A) |
| Media | liquids and gases |
| Medium temperature [°C] | -40…145 |
| Pressure rating [bar] | 400 |
| Electrical data |
|---|
| Operating voltage [V] | 9.6…32 DC; (“supply class 2” to cULus) |
| Current consumption [mA] | < 30 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time [s] | 0.5 |
| Inputs / outputs |
|---|
| Number of inputs and outputs | Number of digital outputs: 2 |
| Outputs |
|---|
| Total number of outputs | 2 |
| Output signal | switching signal |
| Electrical design | PNP |
| Number of digital outputs | 2 |
| Output function | complementary |
| Max. voltage drop switching output DC [V] | 2 |
| Permanent current rating of switching output DC [mA] | 500 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |