Part Number – 101088823
- 1 Cable entry M 20 x 1.5
- Metal enclosure
- Wide range of alternative actuators
- Good resistance to oil and petroleum spirit
- 40,5 mm x 76 mm x 38 mm
- Actuator heads can be repositioned by 4 x 90┬░
- Design to EN 50041
- Actuation from bottom parallel to the switch, therefore only suitable for small housings.
Ordering data
EAN (European Article Number) | 4030661065373 |
eCl@ss number, Version 9.0 | 27-27-26-01 |
eCl@ss number, Version 11.0 | 27-27-26-01 |
ETIM number, version 6.0 | EC000030 |
ETIM number, version 7.0 | EC000030 |
Approval – Standards
Certificates | cULusCCCEAC |
General data
Housing construction form | Norm construction design |
Enclosure material | Light alloy die-casting |
Enclosure coating material | painted |
Material of the contacts, electrical | Silver |
Gross weight | 200 g |
General data – Features
Safety functions | Yes |
Number of auxiliary contacts | 1 |
Number of safety contacts | 1 |
Safety appraisal
Standards | BG-GS-ET-15EN ISO 13849-1EN 60947-5-1 |
Mission Time | 20 Year(s) |
Safety appraisal – Safety outputs
B10d Normally-closed contact (NC) | 20,000,000 Operations |
Mechanical data
Actuating element | Angle roller lever |
Mechanical life, minimum | 30,000,000 Operations |
Actuating force, minimum | 17 N |
Actuating speed, maximum | 0.5 m/s |
Note (Actuating speed) | Actuating speed with actuating angle 30┬░ to switch axis |
Note (Switchover time) | Switchover time in accordance with actuating speed |
Mechanical data – Connection technique
Terminal Connector | Screw connection |
Cable section, minimum | 0.75 mm┬▓ |
Cable section, maximum | 2.5 mm┬▓ |
Note (Cable section) | All indications about the cable section are including the conductor ferrules. |
Mechanical data – Dimensions
Length of sensor | 38 mm |
Width of sensor | 58.3 mm |
Height of sensor | 121.5 mm |
Ambient conditions
Degree of protection | IP65 to EN 60529IP67 to EN 60529 |
Ambient temperature, minimum | -30 ┬░C |
Ambient temperature, maximum | +80 ┬░C |
Ambient conditions – Insulation value
Rated insulation voltage Ui | 500 V |
Rated impulse withstand voltage Uimp | 6 kV |
Electrical data
Thermal test current | 10 A |
Required rated short-circuit current to EN 60947-5-1 | 1,000 A |
Utilisation category AC-15 | 230 VAC |
Utilisation category AC-15 | 4 A |
Utilisation category DC-13 | 24 VDC |
Utilisation category DC-13 | 4 A |
Switching element | NO contact, NC contact |
Switching principle | Slow action |
Bounce duration, maximum | 2 ms |
Switching frequency | 5,000 /h |